  • Kabanshi, Alan (author)
  • Experimental study of an intermittent ventilation system in high occupancy spaces
  • 2017
  • Doctoral thesis (other academic/artistic)abstract
    • Spaces with high occupancy density like classrooms are challenging to ventilate and use a lot of energy to maintain comfort. Usually, a compromise is made between low energy use and good Indoor Environmental Quality (IEQ), of which poor IEQ has consequences for occupants’ health, productivity and comfort. Alternative strategies that incorporate elevated air speeds can reduce cooling energy demand and provide occupant’s comfort and productivity at higher operative temperatures. A ventilation strategy, Intermittent Air Jet Strategy (IAJS), which optimizes controlled intermittent airflow and creates non-uniform airflow and non-isothermal conditions, critical for sedentary operations at elevated temperatures, is proposed herein.The primary aim of the work was to investigate the potential of IAJS as a ventilation system in high occupancy spaces. Ventilation parameters such as air distribution, thermal comfort and indoor air quality are evaluated and the system is compared with a traditional system, specifically, mixing ventilation (MV). A 3-part research process was used: (1) Technical (objective) evaluation of IAJS in-comparison to MV and displacement ventilation (DV) systems. (2) An occupant response study to IAJS. (3) Estimation of the cooling effect under IAJS and its implications on energy use. All studies were conducted in controlled chambers.The results show that while MV and DV creates steady airflow conditions, IAJS has  cyclic airflow profiles which results in a sinusoidal temperature profile around occupants. Air distribution capability of IAJS is similar to MV, both having a generic local air quality index in the occupied zone. On the other hand, the systems overall air change rate was higher than a MV. Thermal comfort results suggest that IAJS generates comfortable thermal climate at higher operative temperatures compared to MV. Occupant responses to IAJS show an improved thermal sensation, air quality perception and acceptability of indoor environment at higher temperatures as compared to MV. A comparative study to estimate the cooling effect of IAJS shows that upper HVAC setpoint can be increased from 2.3 – 4.5 oC for a neutral thermal sensation compared to a MV. This implies a substantial energy saving potential on the ventilation system. In general, IAJS showed a potential for use as a ventilation system in classrooms while promising energy savings.  
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-1 of 1
Type of publication
doctoral thesis (1)
Type of content
other academic/artistic (1)
Author/Editor
Sörqvist, Patrik, Pr ... (1)
Kabanshi, Alan (1)
Wigö, Hans, Dr (1)
Ljung, Robert, Dr (1)
Awbi, Hazim, Profess ... (1)
University
University of Gävle (1)
Language
English (1)
Research subject (UKÄ/SCB)
Engineering and Technology (1)
Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view