1. |
- Isaksson, M, et al.
(author)
-
Patch testing with serial dilutions of budesonide, its R and S diastereomers, and potentially cross-reacting substances
- 2001
-
In: American Journal of Contact Dermatitis. - : Ovid Technologies (Wolters Kluwer Health). - 1046-199X. ; 12:3, s. 170-176
-
Journal article (peer-reviewed)abstract
- BACKGROUND: Budesonide, a marker for corticosteroid allergy, is a 1:1 mixture of 2 diastereomers, the R and S, present in all commercial formulations. Budesonide is said to cross-react with group B substances through the R and S diastereomer and some group D substances only through the S diastereomer. OBJECTIVE: To investigate the cross-reactivity pattern between the R and S diastereomers and 4 potentially cross-reacting substances, 2 from group B and 2 from group D. METHODS: By patch testing 10 patients hypersensitive to budesonide with a serial dilution of budesonide, the R and S diastereomer, triamcinolone acetonide, amcinonide, prednicarbate, and hydrocortisone-17-butyrate. RESULTS: Nine of 10 patients reacted to budesonide and the S diastereomer. Seven of 9 to the R diastereomer. Each of the 9 patients with S diastereomer allergy reacted to the group B and/or group D substances. Five patients reacted to triamcinolone acetonide, not to 1.0% but only to 0.0010% and 0.00010%. CONCLUSION: The R and S diastereomers can induce positive patch test reactions in budesonide-hypersensitive individuals. The potential of budesonide to cross-react with substances from group B and D might be explained by the presence of the 2 diastereomers. When patch testing with triamcinolone acetonide, much lower concentrations than recommended should be used.
|
|