SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "onr:"swepub:oai:DiVA.org:uu-504226" "

Search: onr:"swepub:oai:DiVA.org:uu-504226"

  • Result 1-1 of 1
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Bandert, Anna, et al. (author)
  • In an endotoxaemic model, antibiotic clearance can be affected by different central venous catheter positions, during renal replacement therapy
  • 2023
  • In: Intensive Care Medicine Experimental. - : Springer Nature. - 2197-425X. ; 11:1
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: In intensive care, different central venous catheters (CVC) are often used for infusion of drugs. If a patient is treated with continuous renal replacement therapy (CRRT) a second catheter, a central venous dialysis catheter (CVDC), is needed. Placing the catheters close together might pose a risk that a drug infused in a CVC could be directly aspirated into a CRRT machine and cleared from the blood without giving the effect intended. The purpose of this study was to elucidate if drug clearance is affected by different catheter placement, during CRRT. In this endotoxaemic animal model, an infusion of antibiotics was administered in a CVC placed in the external jugular vein (EJV). Antibiotic clearance was compared, whether CRRT was through a CVDC placed in the same EJV, or in a femoral vein (FV). To reach a target mean arterial pressure (MAP), noradrenaline was infused through the CVC and the dose was compared between the CDVDs.RESULTS: The main finding in this study was that clearance of antibiotics was higher when both catheter tips were in the EJV, close together, compared to in different vessels, during CRRT. The clearance of gentamicin was 21.0 ± 7.3 vs 15.5 ± 4.2 mL/min (p 0.006) and vancomycin 19.3 ± 4.9 vs 15.8 ± 7.1 mL/min (p 0.021). The noradrenaline dose to maintain a target MAP also showed greater variance with both catheters in the EJV, compared to when catheters were placed in different vessels.CONCLUSION: The results in this study indicate that close placement of central venous catheter tips could lead to unreliable drug concentration, due to direct aspiration, during CRRT.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-1 of 1
Type of publication
journal article (1)
Type of content
peer-reviewed (1)
Author/Editor
Larsson, Anders (1)
Frithiof, Robert (1)
Lipcsey, Miklós (1)
Bandert, Anna (1)
Smekal, David, 1971- (1)
University
Uppsala University (1)
Language
English (1)
Research subject (UKÄ/SCB)
Medical and Health Sciences (1)
Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view