  • Weis, J, et al. (author)
  • Magnetic resonance spectroscopic imaging for visualization and correction of distortions in MRI : high precision applications in neurosurgery.
  • 1998
  • In: Magnetic Resonance Imaging. - 0730-725X .- 1873-5894. ; 16:10, s. 1265-72
  • Journal article (peer-reviewed)abstract
    • We present a method for the quantification and correction of geometrical/intensity distortions of magnetic resonance images predominantly caused by bulk magnetic susceptibility shifts due to susceptibility heterogeneities of measured biologic tissues and shape of the object under investigation. The method includes precise and fast measurements of the static magnetic-field distribution inside the measured object and automated data processing. Magnetic-field deviations in the range (-2.4; 2.6) ppm were found in the human brain at B0 = 1.5 T. For routinely used imaging parameters, with a read gradient strength of about approximately 1 mT/m, the magnetic-field perturbations in the human brain can cause geometrical distortions up to +/-4 mm and intensity changes up to +/-50%. MR images corrected by the described method are suitable for planning high precision applications in neurosurgery.
  •  
14.
  • Weis, Jan, et al. (author)
  • NMR imaging of thermal convection patterns
  • 1996
  • In: Magnetic Resonance Imaging. - 0730-725X .- 1873-5894. ; 14:3, s. 319-327
  • Journal article (peer-reviewed)abstract
    • Two special magnetic resonance imaging techniques were applied to the Rayleigh/Bénard problem of thermal convection for the first time. The methods were tested using a water cell with horizontal bottom and top covers kept at different temperatures with a downward gradient. Using Fourier encoding velocity imaging (FEVI) a five-dimensional image data set was recorded referring to two space dimensions of slice-selective images and all three components of the local velocity vector. On this basis, the fields of the velocity components or of the velocity magnitude were evaluated quantitatively and rendered as gray shade images. Furthermore the convection rolls were visualized with the aid of two- or three-dimensional multistripe/multiplane tagging imaging pulse sequences based on two or three DANTE combs for the space directions to be probed. Movies illustrating the fluid motions by convection in all three space dimensions were produced. It is demonstrated that the full spatial information of the convection rolls is accessible with microscopic resolution of typically 100 x 100 x 100 microns3. This resolution is effectively limited by flow displacements in the echo time, which should be well within the voxel dimension. The main perspective of this work is that the combined application of FEVI and multistripe/multiplane tagging imaging permits quantitative examinations of thermal convection for arbitrary boundary conditions and with imposed through-flow apart from the direct visualization of convective flow in the form of movies.
  •  
15.
  • Magnusson, Peter, et al. (author)
  • MRI image plane nonuniformity in evaluation of ferrous sulphate dosimeter gel (FeGel) by means of T1-relaxation time
  • 1999
  • In: Magnetic Resonance Imaging. - 0730-725X. ; 17:9, s. 70-1357
  • Journal article (peer-reviewed)abstract
    • MR image nonuniformity can vary significantly with the spin-echo pulse sequence repetition time. When MR images with different nonuniformity shapes are used in a T1-calculation the resulting T1-image becomes nonuniform. As shown in this work the uniformity TR-dependence of the spin-echo pulse sequence is a critical property for T1 measurements in general and for ferrous sulfate dosimeter gel (FeGel) applications in particular. The purpose was to study the characteristics of the MR image plane nonuniformity in FeGel evaluation. This included studies of the possibility of decreasing nonuniformities by selecting uniformity optimized repetition times, studies of the transmitted and received RF-fields and studies of the effectiveness of the correction methods background subtraction and quotient correction. A pronounced MR image nonuniformity variation with repetition and T1 relaxation time was observed, and was found to originate from nonuniform RF-transmission in combination with the inherent differences in T1 relaxation for different repetition times. The T1 calculation itself, the uniformity optimized repetition times, nor none of the correction methods studied could sufficiently correct the nonuniformities observed in the T1 images. The nonuniformities were found to vary considerably less with inversion time for the inversion-recovery pulse sequence, than with repetition time for the spin-echo pulse sequence, resulting in considerably lower T1 image nonuniformity levels.
  •  
16.
  •  
17.
  •  
18.
  •  
19.
  •  
20.
  • Björkman-Burtscher, Isabella, et al. (author)
  • Quality assessment of localization technique performance in small volume in vivo 1H MR spectroscopy
  • 1999
  • In: Magnetic Resonance Imaging. - 1873-5894. ; 17:10, s. 1511-1519
  • Journal article (peer-reviewed)abstract
    • A new phantom and evaluation method for experimental evaluation of 1H-magnetic resonance spectroscopy single volume localization techniques regarding signal contamination (C), defined as the part of the signal originating outside the volume of interest, is presented. The quality assessment method is based on a spherical phantom with an oil/water interface in order to reduce susceptibility effects, and applied for stimulated-echo acquisition method (STEAM) and spin-echo (SE) sequences, echo times of 270, 135, and 10 ms, and cubic volumes of interest (VOI) of 1(3), 1.5(3), 2(3), 2.5(3), and 3(3) cm3. To be able to mimic measurements of the contamination in three dimensions the physical gradients representing the three orthogonal directions for slice selection were shifted in the pulse sequences. Contamination values in one dimension differed between 6.5% and 8.4% in SE sequences, and between 0.7% and 13.8% in STEAM sequences. In STEAM sequences a decrease of C with increasing VOI size was observed while SE sequences showed comparable C values for the different VOI sizes tested. The total contamination in three dimensions were 19% and 18% in SE and STEAM sequences with a TE of 270 ms, and 7% in a STEAM sequence with a TE of 10 ms, respectively. The presented evaluation method is easily applied to the new phantom and showed high reproducibility.
  •  