SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "(L773:1522 2594 OR L773:0740 3194) srt2:(2015-2019)"

Search: (L773:1522 2594 OR L773:0740 3194) > (2015-2019)

  • Result 1-10 of 56
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Ahlgren, André, et al. (author)
  • A linear mixed perfusion model for tissue partial volume correction of perfusion estimates in dynamic susceptibility contrast MRI: : Impact on absolute quantification, repeatability, and agreement with pseudo-continuous arterial spin labeling
  • 2017
  • In: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 77:6, s. 2203-2214
  • Journal article (peer-reviewed)abstract
    • PURPOSE: The partial volume effect (PVE) is an important source of bias in brain perfusion measurements. The impact of tissue PVEs in perfusion measurements with dynamic susceptibility contrast MRI (DSC-MRI) has not yet been well established. The purpose of this study was to suggest a partial volume correction (PVC) approach for DSC-MRI and to study how PVC affects DSC-MRI perfusion results.METHODS: A linear mixed perfusion model for DSC-MRI was derived and evaluated by way of simulations. Twenty healthy volunteers were scanned twice, including DSC-MRI, arterial spin labeling (ASL), and partial volume measurements. Two different algorithms for PVC were employed and assessed.RESULTS: Simulations showed that the derived model had a tendency to overestimate perfusion values in voxels with high fractions of cerebrospinal fluid. PVC reduced the tissue volume dependence of DSC-MRI perfusion values from 44.4% to 4.2% in gray matter and from 55.3% to 14.2% in white matter. One PVC method significantly improved the voxel-wise repeatability, but PVC did not improve the spatial agreement between DSC-MRI and ASL perfusion maps.CONCLUSION: Significant PVEs were found for DSC-MRI perfusion estimates, and PVC successfully reduced those effects. The findings suggest that PVC might be an important consideration for DSC-MRI applications. Magn Reson Med, 2016. © 2016 Wiley Periodicals, Inc.
  •  
2.
  • Ahlgren, André, et al. (author)
  • Improved calculation of the equilibrium magnetization of arterial blood in arterial spin labeling
  • 2018
  • In: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 80:5, s. 2223-2231
  • Journal article (peer-reviewed)abstract
    • PURPOSE: To propose and assess an improved method for calculating the equilibrium magnetization of arterial blood ( M0a), used for calibration of perfusion estimates in arterial spin labeling.METHODS: Whereas standard M0a calculation is based on dividing a proton density-weighted image by an average brain-blood partition coefficient, the proposed method exploits partial-volume data to adjust this ratio. The nominator is redefined as the magnetization of perfused tissue, and the denominator is redefined as a weighted sum of tissue-specific partition coefficients. Perfusion data were acquired with a pseudo-continuous arterial spin labeling sequence, and partial-volume data were acquired using a rapid saturation recovery sequence with the same readout module. Results from 7 healthy volunteers were analyzed and compared with the conventional method.RESULTS: The proposed method produced improved M0a homogeneity throughout the brain in all subjects. The mean gray matter perfusion was significantly higher with the proposed method compared with the conventional method: 61.2 versus 56.3 mL/100 g/minute (+8.7%). Although to a lesser degree, the corresponding white matter values were also significantly different: 20.8 versus 22.0 mL/100 g/minute (-5.4%). The spatial and quantitative differences between the 2 methods were similar in all subjects.CONCLUSION: Compared with the conventional approach, the proposed method produced more homogenous M0a maps, corresponding to a more accurate calibration. The proposed method also yielded significantly different perfusion values across the whole brain, and performed consistently in all subjects. The new M0a method improves quantitative perfusion estimation with arterial spin labeling, and can therefore be of considerable value in perfusion imaging applications.
  •  
3.
  • Algotsson, Jenny, et al. (author)
  • Electrostatic interactions are important for the distribution of Gd(DTPA)(2-) in articular cartilage.
  • 2015
  • In: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 76:2, s. 500-509
  • Journal article (peer-reviewed)abstract
    • The delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) method can be used to assess the content of glycosaminoglycan in cartilage. In in vitro and model studies, the content of glycosaminoglycan is often expressed in terms of a fixed charge density (FCD). Values of the fixed charge density obtained using the dGEMRIC method differs from values obtained using other methods. The purpose of this work was to further clarify the origin of this discrepancy.
  •  
4.
  • Andersson, Jonathan, et al. (author)
  • Separation of water and fat signal in whole-body gradient echo scans using convolutional neural networks
  • 2019
  • In: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 82:3, s. 1177-1186
  • Journal article (peer-reviewed)abstract
    • Purpose: To perform and evaluate water–fat signal separation of whole‐body gradient echo scans using convolutional neural networks.Methods: Whole‐body gradient echo scans of 240 subjects, each consisting of 5 bipolar echoes, were used. Reference fat fraction maps were created using a conventional method. Convolutional neural networks, more specifically 2D U‐nets, were trained using 5‐fold cross‐validation with 1 or several echoes as input, using the squared difference between the output and the reference fat fraction maps as the loss function. The outputs of the networks were assessed by the loss function, measured liver fat fractions, and visually. Training was performed using a graphics processing unit (GPU). Inference was performed using the GPU as well as a central processing unit (CPU).Results: The loss curves indicated convergence, and the final loss of the validation data decreased when using more echoes as input. The liver fat fractions could be estimated using only 1 echo, but results were improved by use of more echoes. Visual assessment found the quality of the outputs of the networks to be similar to the reference even when using only 1 echo, with slight improvements when using more echoes. Training a network took at most 28.6 h. Inference time of a whole‐body scan took at most 3.7 s using the GPU and 5.8 min using the CPU.Conclusion: It is possible to perform water–fat signal separation of whole‐body gradient echo scans using convolutional neural networks. Separation was possible using only 1 echo, although using more echoes improved the results.
  •  
5.
  • Berglund, Johan, et al. (author)
  • Multi-scale graph-cut algorithm for efficient water-fat separation
  • 2017
  • In: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 78:3, s. 941-949
  • Journal article (peer-reviewed)abstract
    • PurposeTo improve the accuracy and robustness to noise in water-fat separation by unifying the multiscale and graph cut based approaches to B-0-correction.MethodsA previously proposed water-fat separation algorithm that corrects for B-0 field inhomogeneity in 3D by a single quadratic pseudo-Boolean optimization (QPBO) graph cut was incorporated into a multi-scale framework, where field map solutions are propagated from coarse to fine scales for voxels that are not resolved by the graph cut. The accuracy of the single-scale and multi-scale QPBO algorithms was evaluated against benchmark reference datasets. The robustness to noise was evaluated by adding noise to the input data prior to water-fat separation.ResultsBoth algorithms achieved the highest accuracy when compared with seven previously published methods, while computation times were acceptable for implementation in clinical routine. The multi-scale algorithm was more robust to noise than the single-scale algorithm, while causing only a small increase (+10%) of the reconstruction time.ConclusionThe proposed 3D multi-scale QPBO algorithm offers accurate water-fat separation, robustness to noise, and fast reconstruction. The software implementation is freely available to the research community. Magn Reson Med 78:941-949, 2017.
  •  
6.
  • Bidhult, Sebastian, et al. (author)
  • Independent validation of metric optimized gating for fetal cardiovascular phase-contrast flow imaging
  • 2019
  • In: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 81:1, s. 495-503
  • Journal article (peer-reviewed)abstract
    • PURPOSE: To validate metric optimized gating phase-contrast MR (MOG PC-MR) flow measurements for a range of fetal flow velocities in phantom experiments. 2) To investigate intra- and interobserver variability for fetal flow measurements at an imaging center other than the original site.METHODS: MOG PC-MR was compared to timer/beaker measurements in a pulsatile flow phantom using a heart rate (∼145 bpm), nozzle diameter (∼6 mm), and flow range (∼130-700 mL/min) similar to fetal imaging. Fifteen healthy fetuses were included for intra- and interobserver variability in the fetal descending aorta and umbilical vein.RESULTS: Phantom MOG PC-MR flow bias and variability was 2% ± 23%. Accuracy of MOG PC-MR was degraded for flow profiles with low velocity-to-noise ratio. Intra- and interobserver coefficients of variation were 6% and 19%, respectively, for fetal descending aorta; and 10% and 17%, respectively, for the umbilical vein.CONCLUSION: Phantom validation showed good agreement between MOG and conventionally gated PC-MR, except for cases with low velocity-to-noise ratio, which resulted in MOG misgating and underestimated peak velocities and warranted optimization of sequence parameters to individual fetal vessels. Inter- and intraobserver variability for fetal MOG PC-MR imaging were comparable to previously reported values.
  •  
7.
  •  
8.
  •  
9.
  • Brynolfsson, Patrik, et al. (author)
  • Combining phase and magnitude information for contrast agent quantification in dynamic contrast-enhanced MRI using statistical modeling
  • 2015
  • In: Magnetic Resonance in Medicine. - : Wiley-Blackwell. - 0740-3194 .- 1522-2594. ; 74:4, s. 1156-1164
  • Journal article (peer-reviewed)abstract
    • Purpose: The purpose of this study was to investigate, using simulations, a method for improved contrast agent (CA) quantification in DCE-MRI.Methods: We developed a maximum likelihood estimator that combines the phase signal in the DCE-MRI image series with an additional CA estimate, e.g. the estimate obtained from magnitude data. A number of simulations were performed to investigate the ability of the estimator to reduce bias and noise in CA estimates. Noise levels ranging from that of a body coil to that of a dedicated head coil were investigated at both 1.5T and 3T.Results: Using the proposed method, the root mean squared error in the bolus peak was reduced from 2.24 to 0.11 mM in the vessels and 0.16 to 0.08 mM in the tumor rim for a noise level equivalent of a 12-channel head coil at 3T. No improvements were seen for tissues with small CA uptake, such as white matter.Conclusion: Phase information reduces errors in the estimated CA concentrations. A larger phase response from higher field strengths or higher CA concentrations yielded better results. Issues such as background phase drift need to be addressed before this method can be applied in vivo.
  •  
10.
  • Casas Garcia, Belén, et al. (author)
  • 4D Flow MRI-Based Pressure Loss Estimation in Stenotic Flows: Evaluation Using Numerical Simulations
  • 2016
  • In: Magnetic Resonance in Medicine. - : WILEY-BLACKWELL. - 0740-3194 .- 1522-2594. ; 75:4, s. 1808-1821
  • Journal article (peer-reviewed)abstract
    • Purpose: To assess how 4D flow MRI-based pressure and energy loss estimates correspond to net transstenotic pressure gradients (TPG(net)) and their dependence on spatial resolution. Methods: Numerical velocity data of stenotic flow were obtained from computational fluid dynamics (CFD) simulations in geometries with varying stenosis degrees, poststenotic diameters and flow rates. MRI measurements were simulated at different spatial resolutions. The simplified and extended Bernoulli equations, Pressure-Poisson equation (PPE), and integration of turbulent kinetic energy (TKE) and viscous dissipation were compared against the true TPG(net). Results: The simplified Bernoulli equation overestimated the true TPG(net) (8.74 +/- 0.67 versus 6.76 +/- 0.54 mmHg). The extended Bernoulli equation performed better (6.57 +/- 0.53 mmHg), although errors remained at low TPG(net). TPG(net) estimations using the PPE were always close to zero. Total TKE and viscous dissipation correlated strongly with TPG(net) for each geometry (r(2) > 0.93) and moderately considering all geometries (r(2) = 0.756 and r(2) = 0.776, respectively). TKE estimates were accurate and minorly impacted by resolution. Viscous dissipation was overall underestimated and resolution dependent. Conclusion: Several parameters overestimate or are not linearly related to TPG(net) and/or depend on spatial resolution. Considering idealized axisymmetric geometries and in absence of noise, TPG(net) was best estimated using the extended Bernoulli equation. (C) 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 56
Type of publication
journal article (54)
research review (2)
Type of content
peer-reviewed (56)
Author/Editor
Ebbers, Tino (9)
Dyverfeldt, Petter (8)
Knutsson, Linda (5)
Engstrom, M (4)
Skare, S (4)
Szczepankiewicz, Fil ... (4)
show more...
Nilsson, Markus (4)
Maier, Stephan E, 19 ... (4)
Lantz, Jonas (4)
Avventi, E (4)
Garpebring, Anders (3)
Starck, Göran (3)
Topgaard, Daniel (3)
Ahlgren, André (3)
Wirestam, Ronnie (3)
Heiberg, Einar (3)
Ljungberg, Maria (3)
Carlhäll, Carljohan (3)
Westin, Carl-Fredrik (3)
Montelius, Mikael, 1 ... (3)
Bidhult, Sebastian (3)
Van Zijl, Peter C M (3)
Xu, Jiadi (3)
Dahlqvist Leinhard, ... (2)
Sigfridsson, A (2)
Ugander, M (2)
Ahlström, Håkan, 195 ... (2)
Carlsson, Marcus (2)
Özarslan, Evren (2)
Lind, Emelie (2)
Ståhlberg, Freddy (2)
Kullberg, Joel, 1979 ... (2)
Arheden, Håkan (2)
Berglund, Johan (2)
Jalnefjord, Oscar, 1 ... (2)
Hedström, Erik (2)
Töger, Johannes (2)
Sigfridsson, Andreas (2)
Norbeck, O (2)
Petersson, Sven (2)
Zachrisson, Helene (2)
de Muinck, Ebo (2)
Xu, Xiang (2)
Martensson, M (2)
Holst, K. (2)
van Osch, Matthias J ... (2)
Ryden, H (2)
Chan, Kannie W Y (2)
Liu, Guanshu (2)
Mulkern, Robert V (2)
show less...
University
Lund University (19)
Linköping University (15)
Karolinska Institutet (11)
University of Gothenburg (7)
Uppsala University (7)
Umeå University (6)
show more...
Royal Institute of Technology (1)
show less...
Language
English (56)
Research subject (UKÄ/SCB)
Medical and Health Sciences (42)
Natural sciences (12)
Engineering and Technology (12)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view