SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0720 048X OR L773:1872 7727 srt2:(2005-2009)"

Sökning: L773:0720 048X OR L773:1872 7727 > (2005-2009)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bornefalk, Hans, et al. (författare)
  • Single-shot dual-energy subtraction mammography with electronic spectrum splitting : Feasibility
  • 2006
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 0720-048X .- 1872-7727. ; 60:2, s. 275-278
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a single-shot dual-energy subtraction mammography technique using an energy sensitive photon counting detector. An electronic threshold near the middle of the X-ray spectrum discriminates between high- and low-energy photons, and allows the simultaneous acquisition of high- and low-energy images which can be combined to suppress anatomical clutter. By setting the electronic threshold close to 33.2 keV (the k-edge of iodine) the system is optimized for dual-energy contrast-enhanced imaging of breast tumors. This method eliminates the need for separate exposures which might otherwise lead to motion artifacts. The method is illustrated in phantom images.
  •  
2.
  • Diaz, Sandra, et al. (författare)
  • Validity of apparent diffusion coefficient hyperpolarized He-3-MRI using MSCT and pulmonary function tests as references
  • 2009
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 1872-7727 .- 0720-048X. ; 71:2, s. 257-263
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To compare apparent diffusion coefficient (ADC) measurements from hyperpolarized (HP) helium (He-3)-magnetic resonance imaging (MRI) with quantitative data from multislice Computed Tomography (CT) (MSCT) of the whole lungs and pulmonary function tests (PFT). Materials and methods: Twenty-seven subjects, 22 with established emphysema and 5 with preclinical emphysema defined by PFT criteria, were examined with Hp He-3-MRI and MSCT. Mean age was 55 (+/- 12) years, 18 female and 9 male. Mean ADC from He-3-MRI was compared with emphysema index (EI), 15th percentile and mean lung density (MLD) values from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. Results: Mean ADC and standard deviation values were 0.392 +/- 0.119 cm(2)/s for the established emphysema group and 0.216 +/- 0.046 for the pre-clinical emphysema group. MSCT values for the established emphysema group and pre-clinical emphysema group were: EI (%) 11 +/- 12 and 0.4 +/- 0.6, respectively; 15th percentile (Hounsfield Units (HU)), -956 +/- 25 and -933 +/- 13, respectively and MLD (HU) -877 +/- 20 and -863 +/- 15, respectively. Correlations between mean ADC and El and 15th percentile were both r=0.90 and for MLD r=0.59. There was higher correlation between mean ADC and %predicted DLCO (r=0.90) than between El and %predicted DLCO (r=0.76). Conclusion: Hp He-3-MRI correlates well with density measurements from MSCT and agrees better than MSCT with %predicted DLCO which is the PFT most related to emphysema. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
  •  
3.
  • Helms, Gunther (författare)
  • The principles of quantification applied to in vivo proton MR spectroscopy
  • 2008
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 1872-7727 .- 0720-048X. ; 67:2, s. 218-229
  • Forskningsöversikt (refereegranskat)abstract
    • Following the identification of metabolite signals in the in vivo MR spectrum, quantification is the procedure to estimate numerical values of their concentrations. The two essential steps are discussed in detail: analysis by fitting a model of prior knowledge, that is, the decomposition of the spectrum into the signals of singular metabolites; then, normalization of these signals to yield concentration estimates. Special attention is given to using the in vivo water signal as internal reference.
  •  
4.
  • Hennings, Joakim, et al. (författare)
  • Computed tomography, magnetic resonance imaging and 11C-metomidate positron emission tomography for evaluation of adrenal incidentalomas
  • 2009
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 0720-048X .- 1872-7727. ; 69:2, s. 314-23
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Given the higher sensitivity of modern computed tomography (CT) scanners, adrenal incidentalomas are being discovered increasingly often. This implies a growing quantitative diagnostic and clinical problem. CT and/or magnetic resonance imaging (MRI) and usually thorough hormonal testing are routinely used to determine the origin of these lesions. Recently, positron emission tomography (PET) using the tracer (11)C-metomidate (MTO) has been established as an alternative diagnostic method with high sensitivity for identifying adrenocortical lesions. The aim of this study was to evaluate the clinical use and value of MTO-PET compared to CT and MRI in the characterisation and work-up of adrenal incidentalomas. METHODS: Initially, we retrospectively evaluated 20 adrenal incidentalomas in patients who had undergone CT, MRI and MTO-PET and from whom we had either histopathological diagnosis or clinical follow-up data. After this analysis we conducted a prospective study in order to compare the imaging modalities. In the latter study, 24 incidentalomas were imaged by CT, MRI and MTO-PET and the results were correlated to those from histopathology (n=8) and clinical diagnosis after follow-up (n=16). RESULTS: In the retrospective analysis, MRI and especially MTO-PET, correlated well to histopathology and clinical diagnosis after follow-up, whereas specificity with CT was low. This was possibly due to the presence of several haematomas/fibrosis which were misdiagnosed as adrenocortical adenomas. In the prospective cohort, sensitivity and specificity with CT were 0.71 and 1.0, respectively, and further characterisation by MRI increased these values to 0.86 and 1.0, whereas maximum sensitivity and specificity were reached when MTO-PET was added. CONCLUSION: The diagnosis of an adrenocortical adenoma may be established by CT in most patients and by MRI in an additional number. For the few remaining patients needing further characterisation, MTO-PET is advantageous as an additional imaging modality.
  •  
5.
  • Kanis, John A, et al. (författare)
  • Assessment of fracture risk
  • 2009
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 0720-048X .- 1872-7727. ; 71:3, s. 392-7
  • Tidskriftsartikel (refereegranskat)abstract
    • Fractures are a common complication of osteoporosis. Although osteoporosis is defined by bone mineral density at the femoral neck, other sites and validated techniques can be used for fracture prediction. Several clinical risk factors contribute to fracture risk independently of BMD. These include age, prior fragility fracture, smoking, excess alcohol, family history of hip fracture, rheumatoid arthritis and the use of oral glucocorticoids. These risk factors in conjunction with BMD can be integrated to provide estimates of fracture probability using the FRAX tool. Fracture probability rather than BMD alone can be used to fashion strategies for the assessment and treatment of osteoporosis.
  •  
6.
  • Morcos, Sameh K., et al. (författare)
  • Reducing the risk of iodine-based and MRI contrast media administration : recommendation for a questionnaire at the time of booking
  • 2008
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 0720-048X .- 1872-7727. ; 66:2, s. 225-229
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents a practical questionnaire to be used when a contrast medium examination is requested. The questionnaire is based on the guidelines from the European Society of Urogenital Radiology. Its aim is to identify patients at increased risk of clinically relevant renal and non-renal adverse reactions to iodine-based and MRI contrast agents. The questionnaire should be completed by the referring physician when the examination is requested.
  •  
7.
  • Norén, Bengt, 1955-, et al. (författare)
  • Separation of advanced from mild fibrosis in diffuse liver disease using 31P magnetic resonance spectroscopy
  • 2008
  • Ingår i: European Journal of Radiology. - : Elsevier. - 0720-048X .- 1872-7727. ; 66:2, s. 313-320
  • Tidskriftsartikel (refereegranskat)abstract
    • 31P-MRS using DRESS was used to compare absolute liver metabolite concentrations (PME, Pi, PDE, γATP, αATP, βATP) in two distinct groups of patients with chronic diffuse liver disorders, one group with steatosis (NAFLD) and none to moderate inflammation (n = 13), and one group with severe fibrosis or cirrhosis (n = 16). All patients underwent liver biopsy and extensive biochemical evaluation. A control group (n = 13) was also included. Absolute concentrations and the anabolic charge, AC = {PME}/({PME} + {PDE}), were calculated.Comparing the control and cirrhosis groups, lower concentrations of PDE (p = 0.025) and a higher AC (p < 0.001) were found in the cirrhosis group. Also compared to the NAFLD group, the cirrhosis group had lower concentrations of PDE (p = 0.01) and a higher AC (p = 0.009). No significant differences were found between the control and NAFLD group. When the MRS findings were related to the fibrosis stage obtained at biopsy, there were significant differences in PDE between stage F0–1 and stage F4 and in AC between stage F0–1 and stage F2–3.Using a PDE concentration of 10.5 mM as a cut-off value to discriminate between mild, F0–2, and advanced, F3–4, fibrosis the sensitivity and specificity were 81% and 69%, respectively. An AC cut-off value of 0.27 showed a sensitivity of 93% and a specificity of 54%.In conclusion, the results suggest that PDE is a marker of liver fibrosis, and that AC is a potentially clinically useful parameter in discriminating mild fibrosis from advanced.
  •  
8.
  • Persson, Anders, 1953-, et al. (författare)
  • Advances of dual source, dual-energy imaging in postmortem CT
  • 2008
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 0720-048X .- 1872-7727. ; 68:3, s. 446-455
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper focuses on the use of multi-detector row dual-energy computed tomography (DECT) in the evaluation of postmortal examinations. The use of dual energy moves postmortem CT to an entirely new dimension of diagnostic sensitivity where contrast in the image is not merely limited to X-ray attenuation differences, but may include elements of functional and tissue characterization. This additional information may be used to improve the benefit postmortem imaging can provide to supplement and simplify the conventional autopsy. © 2008 Elsevier Ireland Ltd. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8
Språk
Engelska (8)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (4)
Teknik (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy