1.
  • Ören, Ünal, et al. (author)
  • Detection of radioactive fragments in patients after radiological or nuclear emergencies using computed tomography and digital radiography.
  • 2014
  • In: Journal of Radiological Protection. - : IOP Publishing. - 1361-6498 .- 0952-4746. ; 34:1, s. 231-247
  • Journal article (peer-reviewed)abstract
    • A comparison has been carried out between standard-dose computed tomography, non-diagnostic computed tomography and digital radiography with respect to their suitability for detecting radioactive fragments associated with nuclear or radiological events such as debris from radiological dispersal devices. The purpose was to investigate if radiographic imaging is justified for the detection and localisation of radioactive fragments in affected patients.Fragments of uranium (U), copper (Cu), iron (Fe) and volcanic ash with effective diameters ranging from (approximately) 100 to 700 μm were selected. The fragments were positioned at two different locations on an anatomical torso phantom and images were produced with standard-dose CT, non-diagnostic CT and digital radiography. Capsules with radionuclides of (137)Cs, (60)Co and (99m)Tc were also positioned in the phantom and the effective doses were estimated for radionuclide exposures as well as for standard-dose CT, non-diagnostic CT and digital radiography. For standard-dose CT and digital radiography, U, Cu and Fe fragments were detected in sizes down to 100-180, 250-300 and 300-400 μm respectively. For the non-diagnostic CT the results were 180-250 μm (for U), 300-400 μm (for Cu) and 400-500 μm (for Fe). The effective dose from the standard-dose CT, non-diagnostic CT and digital radiography was 5.6, 1.9 and 0.76 mSv. Corresponding doses from (137)Co, (60)Co and (99m)Tc positioned at the site of fragments were in the range of 0.07-0.1, 0.32-0.45 and 0.08-0.09 mSv per MBq during 24 h. We conclude that, for a number of gamma emitters with activity levels on the order of magnitude of megabecquerel, imaging using ionising radiation can be justified since the effective dose from the radionuclides will exceed the dose from the radiological examination.
  •  
2.
  • Högberg, Jonas, 1976, et al. (author)
  • Radiation exposure during liver surgery after treatment with (90)Y microspheres, evaluated with computer simulations and dosimeter measurements.
  • 2012
  • In: Journal of radiological protection : official journal of the Society for Radiological Protection. - : IOP Publishing. - 1361-6498. ; 32:4, s. 439-46
  • Journal article (peer-reviewed)abstract
    • Purpose. Two patients with liver tumours were planned for a combined treatment, including surgery with preceding injections of β(-) radiation emitting (90)Y microspheres (SIRTEX(®)). The aim of this paper is to present a method of pre-surgical computer simulations of the absorbed dose rate on the surface of tumour tissue, combined with measurements of the actual absorbed dose rate on resected tissue, in order to estimate the absorbed dose to a surgeon's fingers during such surgery procedures. Methods and Materials. The dose rates from β(-) radiation on the surface of tumour tissue were simulated with the software VARSKIN(®)Mod2. The activity concentrations in tumours were estimated, based on SPECT/CT distribution studies of (99m)Tc-MAA and confirmed by SPECT/CT bremsstrahlung studies of (90)Y microspheres. The activity distributions were considered as homogeneous within the tumour regions. The absorbed dose rates at different tumour tissue spots were calculated based on measurements with thermo-luminescent dosimeters (TLD) fastened on resected tissue. Results. The simulations showed a good agreement with the averaged absorbed dose rates based on TLD measurements performed on resected tissue, differing by 13% and 4% respectively. The absorbed dose rates at the measured maximum hotspots were twice as high as the average dose rates for both patients. Conclusion. The data is not sufficient in order to draw any general conclusions about dose rates on tumour tissue during similar surgeries, neither about the influence of dose rate heterogeneities nor about average dose rates. However, the agreement between simulations and measurements on these limited data indicate that this approach is a promising method for estimations of the radiation exposure to the surgeons' fingers during this kind of surgery procedure. More data from similar surgeries are necessary in order to validate the method.
  •  
3.
  • Magee, Jill S, et al. (author)
  • Derivation and application of dose reduction factors for protective eyewear worn in interventional radiology and cardiology.
  • 2014
  • In: Journal of radiological protection : official journal of the Society for Radiological Protection. - : IOP Publishing. - 1361-6498. ; 34:4, s. 811-823
  • Journal article (peer-reviewed)abstract
    • Doses to the eyes of interventional radiologists and cardiologists could exceed the annual limit of 20mSv proposed by the International Commission on Radiological Protection. Lead glasses of various designs are available to provide protection, but standard eye dosemeters will not take account of the protection they provide. The aim of this study has been to derive dose reduction factors (DRFs) equal to the ratio of the dose with no eyewear, divided by that when lead glasses are worn. Thirty sets of protective eyewear have been tested in x-ray fields using anthropomorphic phantoms to simulate the patient and clinician in two centres. The experiments performed have determined DRFs from simulations of interventional procedures by measuring doses to the eyes of the phantom representing the clinician, using TLDs in Glasgow, Scotland and with an electronic dosemeter in Gothenburg, Sweden. During interventional procedures scattered x-rays arising from the patient will be incident on the head of the clinician from below and to the side. DRFs for x-rays incident on the front of lead glasses vary from 5.2 to 7.6, while values for orientations similar to those used in the majority of clinical practice are between 1.4 and 5.2. Specialised designs with lead glass side shields or of a wraparound style with angled lenses performed better than lead glasses based on the design of standard spectacles. Results suggest that application of a DRF of 2 would provide a conservative factor that could be applied to personal dosemeter measurements to account for the dose reduction provided by any type of lead glasses provided certain criteria relating to design and consistency of use are applied.
  •  
4.
  • Salomaa, Sisko, et al. (author)
  • State of the art in research into the risk of low dose radiation exposure-findings of the fourth MELODI workshop
  • 2013
  • In: Journal of Radiological Protection. - : IOP Publishing. - 0952-4746 .- 1361-6498. ; 33:3, s. 589-603
  • Journal article (peer-reviewed)abstract
    • The fourth workshop of the Multidisciplinary European Low Dose Initiative (MELODI) was organised by STUK-Radiation and Nuclear Safety Authority of Finland. It took place from 12 to 14 September 2012 in Helsinki, Finland. The meeting was attended by 179 scientists and professionals engaged in radiation research and radiation protection. We summarise the major scientific findings of the workshop and the recommendations for updating the MELODI Strategic Research Agenda and Road Map for future low dose research activities.
  •  
5.
  • Sandblom, Viktor, 1987, et al. (author)
  • Evaluation of the impact of a system for real-time visualisation of occupational radiation dose rate during fluoroscopically guided procedures
  • 2013
  • In: Journal of Radiological Protection. - : IOP Publishing. - 0952-4746 .- 1361-6498. ; 33:3, s. 693-702
  • Journal article (peer-reviewed)abstract
    • Optimisation of radiological protection for operators working with fluoroscopically guided procedures has to be performed during the procedure, under varying and difficult conditions. The aim of the present study was to evaluate the impact of a system for real-time visualisation of radiation dose rate on optimisation of occupational radiological protection in fluoroscopically guided procedures. Individual radiation dose measurements, using a system for real-time visualisation, were performed in a cardiology laboratory for three cardiologists and ten assisting nurses. Radiation doses collected when the radiation dose rates were not displayed to the staff were compared to radiation doses collected when the radiation dose rates were displayed. When the radiation dose rates were displayed to the staff, one cardiologist and the assisting nurses (as a group) significantly reduced their personal radiation doses. The median radiation dose (Hp(10)) per procedure decreased from 68 to 28 μSv (p = 0.003) for this cardiologist and from 4.3 to 2.5 μSv (p = 0.001) for the assisting nurses. The results of the present study indicate that a system for real-time visualisation of radiation dose rate may have a positive impact on optimisation of occupational radiological protection. In particular, this may affect the behaviour of staff members practising inadequate personal radiological protection.
  •  
6.
  • Wojcik, Andrzej, et al. (author)
  • Chromosomal aberrations in peripheral blood lymphocytes exposed to a mixed beam of low energy neutrons and gamma radiation
  • 2012
  • In: Journal of Radiological Protection. - : IOP Publishing. - 0952-4746 .- 1361-6498. ; 32:3, s. 261-274
  • Journal article (peer-reviewed)abstract
    • Cells exposed to thermal neutrons are simultaneously damaged by radiations with high and low linear energy transfer (LET). A question relevant for the assessment of risk of exposure to a mixed beam is whether the biological effect of both radiation types is additive or synergistic. The aim of the present investigation was to calculate whether the high and low LET components of a thermal neutron field interact when damaging cells. Human peripheral blood lymphocytes were exposed to neutrons from the HB11 beam at the Institute for Energy and Transport, Petten, Netherlands, in a 37 degrees C water phantom at varying depths, where the mix of high and low LET beam components differs. Chromosomal aberrations were analysed and the relative biological effectiveness (RBE) values as well as the expected contributions of protons and photons to the aberration yield were calculated based on a dose response of aberrations in lymphocytes exposed to Co-60 gamma radiation. The RBE for 10 dicentrics per 100 cells was 3 for mixed beam and 7.2 for protons. For 20 dicentrics per 100 cells the respective values were 2.4 and 5.8. Within the limitations of the experimental setup the results indicate that for this endpoint there is no synergism between the high and low LET radiations.
  •  
7.
  •  