SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Andersson Tomas) srt2:(1990-1994)"

Search: WFRF:(Andersson Tomas) > (1990-1994)

  • Result 1-8 of 8
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  •  
3.
  •  
4.
  • Andersson, Maria, 1965- (author)
  • Cost-effective incentives for local electric utilities and industries in co-operation : modelling of technical measures
  • 1993
  • Licentiate thesis (other academic/artistic)abstract
    • In the Swedish electricity system there is a great potential for increasing the cost efficiency of the electricity use. However, today the economic incentives, offered for instance by existing electricity rates, are too weak to improve the use of the system. On the Swedish electricity market there are, at least, three different actors, the power producer, the distributor and the customer. Today these actors act separately due to low awareness of the costs for electricity generation, over the year and the day. If the actors are aware of the real electricity costs, cost-effective incentives will arise to introduce energy system measures that will reduce the energy system cost considerably. The thesis presents two energy system analyses of an existing Swedish municipality. The first analysis deals with the introduction of industrial end-use measures, with the local utility’s existing electricity rates as boundary conditions. The analysis is carried out with a simulation model for electricity use in industries. The second analysis deals with the introduction of energy system measures, on the municipal supply-side and demand-side, when the local electric utility and the customers are regarded as one system. The analysis is carried out with an optimization model, that is based on linear programming. The results show that if 17 industries introduce end-use measures, with the existing electricity rates as boundary conditions, their energy system costs will be reduced by 12 MSEK for a time period of 10 years, whereas the local utility will increase its energy system cost by 6 MSEK. However, if there is a co-operation between the local electric utility and the customers, their joint energy system cost will be reduced by 330 MSEK for a time period of 10 years.
  •  
5.
  •  
6.
  • Kirkhorn, Tomas, et al. (author)
  • Demonstration of digital radiographs by means of ink jet-printed paper copies : Pilot study
  • 1992
  • In: Journal of Digital Imaging. - 0897-1889. ; 5:4, s. 246-251
  • Journal article (peer-reviewed)abstract
    • Different digital medical images have been printed on paper with a continuous ink jet printer, and the quality has been evaluated. The emphasis has been on digital chest radiographs from a computed radiography system. The ink jet printing technique is described as well as the handling of the image data from image source to printer. Different versions of paper prints and viewing conditions were compared to find the optimum alternative. The evaluation has been performed to maximize the quality of the paper images to make them conform with the corresponding film prints and monitor images as much as possible. The continuous ink jet technique offers high-quality prints on paper at a considerably lower cost per copy compared with the cost of a film print. With a future switch-over from diagnosing of digital images on film to diagnosing them on monitors, hard copies for demonstration purposes will occasionally be needed. This need can be filled by ink jetprinted paper copies.
  •  
7.
  • Lyttkens, Kerstin, et al. (author)
  • Evaluation of the image quality of ink-jet printed paper copies of digital chest radiographs as compared with film : A receiver operating characteristic study
  • 1994
  • In: Journal of Digital Imaging. - 0897-1889. ; 7:2, s. 61-68
  • Journal article (peer-reviewed)abstract
    • Paper copies of digital radiographs printed with the continuous ink-jet technique have proved to be of a high enough quality for demonstration purposes. We present a study on the image quality of ink-jet printed paper copies of digital chest radiographs, based on receiver operating characteristic (ROC) analysis. Eighty-three digital radiographs of a chest phatom with simulated tumors in the mediastinum and right lund, derived from a computed radiography (CR) system were presented in two series of hard copies as ink-jet printed paper copies and as laser recorded film. The images, with a matrix of 1,760×2,140 pixels, were printed with a spatial resolution of 10 pixels/mm in the CR film recorder as well as in the ink-jet printer. On film, every image was recorded in two versions, one optimized for the mediastinum and one for the lungs. On paper, only one image was printed; this constituted an effort to optimize both the mediastinum and the lungs. The ink-jet printed images, printed on a matt coated paper, were viewed as on-sight images with reflected light. The exdaminations were reviewed by six radiologists, and ROC curves were constructed. No significant difference was found between the performance of film and that of ink-jet paper prints. Because the cost for a paper copy is only a tenth of that of film, remarkable cost reductions can be achieved by using the ink jet technique instead. Our results show that further quality studies of ink-jet printed images are worthwhile.
  •  
8.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-8 of 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view