SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Brismar Torkel) srt2:(2005-2009)"

Sökning: WFRF:(Brismar Torkel) > (2005-2009)

  • Resultat 1-10 av 14
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brismar, Torkel, et al. (författare)
  • Liver Vessel Enhancement by Gd-BOPTA and Gc-EOB-DTPA – a Comparison in Healthy Volunteers.
  • 2009
  • Ingår i: Acta Radiologica. - : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 50:7, s. 709-715
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: A thorough understanding of magnetic resonance (MR) contrast media dynamics makes it possible to choose the optimal contrast media for each investigation. Differences in visualizing hepatobiliary function between Gd-BOPTA and Gd-EOB-DTPA have previously been demonstrated, but less has been published regarding differences in liver vessel visualization.Purpose: To compare the liver vessel and liver parenchymal enhancement dynamics of Gd-BOPTA (MultiHance®) and Gd-EOB-DTPA (Primovist®). Material and Methods: The signal intensity of the liver parenchyma, the common hepatic artery, the middle hepatic vein, and a segmental branch of the right portal vein, was obtained in 10 healthy volunteers before contrast media administration, during arterial and portal venous phases, and 10, 20, 30, 40 and 130 minutes after intravenous contrast medium injection, but due to scanner limitations not during the hepatic venous phase. Results: Maximum enhancement of liver parenchyma was observed from the portal venous phase until 130 minutes after Gd-BOPTA administration and from 10 minutes to 40 minutes after Gd-EOB-DTPA. There was no difference in maximum enhancement of liver parenchyma between the two contrast media. When using Gd-BOPTA, the vascular contrast enhancement was still apparent 40 minutes after injection, but had vanished 10 minutes after Gd-EOB-DTPA injection. The maximum difference in signal intensity between the vessels and the liver parenchyma was significantly greater with Gd-BOPTA than with Gd-EOB-DTPA (p<0.0001). Conclusion: At the dosage used in this study Gd-BOPTA yields higher maximum enhancement of the hepatic artery, portal vein and middle hepatic vein during the arterial and the portal venous phase and during the delayed phases than Gd-EOB-DTPA does, whereas there is no difference in liver parenchymal enhancement between the two contrast agents.
  •  
2.
  •  
3.
  •  
4.
  • Dahlström, Nils, 1969-, et al. (författare)
  • Contrast-enhanced magnetic resonance cholangiography with Gd-BOPTA and Gd-EOB-DTPA in healthy subjects
  • 2007
  • Ingår i: Acta Radiologica. - : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 48:4, s. 362-368
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate the biliary enhancement dynamics of the two gadolinium chelates Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist) in normal healthy subjects. MATERIAL AND METHODS: Ten healthy volunteers were evaluated with both agents by magnetic resonance (MR) imaging at 1.5T using a breath-hold gradient-echo T1-weighted VIBE sequence. The relative signal intensity (SI) differences between the common hepatic duct (CHD) and liver parenchyma were measured before and 10, 20, 30, 40, 130, 240, and 300 min after contrast medium injection. RESULTS: Biliary enhancement was obvious 10 min post-injection for Gd-EOB-DTPA and was noted at 20 min for Gd-BOPTA. At 40 min delay, Gd-BOPTA reached its peak biliary enhancement, but at neither 30 nor 40 min delay was there any significant difference compared with that of Gd-EOB-DTPA. At later delays, the contrast between CHD and liver continued to increase for Gd-EOB-DTPA, whereas it decreased for Gd-BOPTA. CONCLUSION: The earlier onset and longer duration of a high contrast between CHD and liver for Gd-EOB-DTPA facilitates examination of hepatobiliary excretion. Therefore, Gd-EOB-DTPA may provide adequate hepatobiliary imaging within a shorter time span than Gd-BOPTA and facilitate scheduling at the MR unit. Further studies in patients are required to compare the imaging advantages of Gd-EOB-DTPA and Gd-BOPTA in clinical practice.
  •  
5.
  •  
6.
  • Dahlström, Nils, 1969- (författare)
  • Magnetic Resonance Imaging of the Hepatobiliary System Using Hepatocyte-Specific Contrast Media
  • 2009
  • Licentiatavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • There are two Gadolinium-based liver-specific contrast media for Magnetic Resonance Imaging on the market, Gd-BOPTA (MultiHance®, Bracco Imaging, Milan, Italy) and Gd-EOB-DTPA (Primovist®, Bayer Schering Pharma, Berlin, Germany). The aim of this study in two parts was to evaluate the dynamics of biliary, parenchymal and vascular enhancement using these contrast media in healthy subjects. Ten healthy volunteers were examined in a 1.5 T magnetic resonance system using three-dimensional Volumetric Interpolated Breath-Hold (VIBE) sequences for dynamic imaging with both contrast media – at two different occasions – until five hours after injection. The doses given were 0.025 mmol/kg for Gd-EOB-DTPA and 0.1 mmol/kg for Gd-BOPTA. The enhancement over time of the common biliary duct in contrast to the liver parenchyma was analyzed in the first study. This was followed by a study of the image contrasts of the hepatic artery, portal vein and middle hepatic vein versus the liver parenchyma.While Gd-EOB-DTPA gave an earlier and more prolonged enhancement of the biliary duct, Gd-BOPTA achieved higher image contrast for all vessels studied, during the arterial and portal venous phases. There was no significant difference in the maximal enhancement obtained in the liver parenchyma.At the obtained time-points and at the dosage used, the high contrast between the common biliary duct and liver parenchyma had an earlier onset and longer duration for Gd-EOB-DTPA, while Gd-BOPTA achieved higher maximal enhancement of the hepatic artery, portal vein and middle hepatic vein than Gd-EOB-DTPA. Diseases of the liver and biliary system may affect the vasculature, parenchyma, biliary excretion or a combination of these. The clinical context regarding the relative importance of vascular, hepatic parenchymal and biliary processes should determine the choice of contrast media for each patient and examination. 
  •  
7.
  • Grishenkov, Dmitry, 1983-, et al. (författare)
  • Acoustic properties of polymer-shelled ultrasound contrast agents. Bulk volume vs. microcapillary
  • 2009
  • Ingår i: 16th International Congress on Sound and Vibration 2009, ICSV 2009. - Krakow. - 9781615677368 ; , s. 2515-2522
  • Konferensbidrag (refereegranskat)abstract
    • The focus of contrast-enhanced ultrasound research has developed beyond detecting the blood pool to new areas such as perfusion imaging, drug and gene therapy, and targeted imaging. Polymer-shelled microbubbles are proposed as a new generation of ultrasound contrast agents (UCAs) which fulfil the requirements of these applications. With a shelf-life of several months and possibility to conjugate pharmacological molecules to their surface, these UCAs will allow not only to enhance the contrast of ultrasound images, but also to function as carriers of drugs to be delivered locally. In this study, the results of an experimental investigation of three types of UCAs stabilized by thick poly vinyl alcohol (PVA) shell are presented. These UCAs are synthesized from a PVA aqueous solution under varied pH values and temperature. The UCAs differ from each other in their average diameter, shell thickness and polydispersity. Knowledge of the peak negative pressure at which the solid shell fractures is paramount for a proper use of UCAs. Therefore, the dependence of this quantity on temperature and number of cycles in the incident pulse is examined. Much of the blood volume resides in the microcirculation, with capillaries playing a particularly important role in patho-physiology and drug delivery. In this sense in vitro characterization of the UCAs oscillation was moved from bulk volume to the capillary scale, where tissue-bubble interaction takes place. The main conclusion to be drawn from these results is that the shell of the UCAs begin to fracture at values of mechanical index (MI) approved for clinical applications. The fatigue, i.e. the accumulation of damage within the shell of the UCAs, is found to play an important role in fracturing the shell. Finally adhesion of the UCAs to the elastic wall is studied and correlated with estimates of the shell’s visco-elastic constants. Open questions arising from this comparison are briefly discussed.
  •  
8.
  • Grishenkov, Dmitry, 1983-, et al. (författare)
  • Characterization of acoustic properties of PVA-shelled ultrasound contrast agents : linear properties (Part I)
  • 2009
  • Ingår i: Ultrasound in Medicine and Biology. - : Elsevier BV. - 0301-5629 .- 1879-291X. ; 35:7, s. 1127-1138
  • Tidskriftsartikel (refereegranskat)abstract
    • This work examines the linear acoustic behavior of ultrasound contrast agents made of three types of poly (vinyl alcohol) (PVA) shelled microbubbles manufactured at different pH and temperature conditions. Back-scattered power, attenuation coefficient and phase velocity of ultrasonic waves propagating through suspensions of PVA contrast agents were measured at temperature values ranging between 24 degrees C and 37 degrees C in a frequency range from 3 MHz to 13 MHz. Enhancement of the backscattered power higher than 20 dB and displaying a weak dependence on temperature was observed. Attenuation and phase velocity, on the other hand, showed higher sensitivity to temperature variations. A modified version of the Church model, which accounts for the dispersion of the dynamic modulus of the PVA shells, was developed to simultaneously fit the attenuation and phase velocity data at 24 degrees C. The frequency dependence of the storage modulus was found to be that of semiflexible polymeric networks. On the other hand, the frequency dependence of the dynamic loss modulus suggests that additional mechanisms, which may be related to the finite dimensions of the shell and/or to its inhomogeneity, may play a significant role in the dissipation of the acoustic energy. For the microbubbles of interest, this model predicts frequency dependent resonance frequency higher than 100 MHz.
  •  
9.
  • Grishenkov, Dmitry, 1983-, et al. (författare)
  • Characterization of acoustic properties of PVA-shelled ultrasound contrast agents : ultrasound-induced fracture (Part II)
  • 2009
  • Ingår i: Ultrasound in Medicine and Biology. - : Elsevier BV. - 0301-5629 .- 1879-291X. ; 35:7, s. 1139-1147
  • Tidskriftsartikel (refereegranskat)abstract
    • Knowledge of the magnitude of the peak negative pressure, P-thr, at which ultrasound contrast agents fracture is relevant for using these microbubbles both as devices for contrast enhancement purposes, as well as carriers of drugs to be delivered locally. In the second part of this communication, the acoustic properties of three types of microbubbles stabilized by poly (vinyl alcohol) (PVA) shells are further investigated. In particular, the dependence of P-thr on system parameters such as the number of cycles, frequency and exposure is examined. The effects of temperature, blood and, wherever data are available, of the dimension of the microbubbles on P-thr are also considered. The large shelf thickness notwithstanding, the results of this investigation show that at room temperature, PVA contrast agents fracture at negative peak pressure values within the recommended safety limit. Furthermore, P-thr decreases with increasing temperature, radius of the microbubbles and number of cycles of the incident wave. Fatigue seems to be a physical mechanism playing a dominant role in the fracture process. The effect of blood on P-thr varies according to condition under which the microbubbles have been synthesized, although stiffening of the shell is observed in most cases. In conclusion, these results suggest that PVA-shelled microbubbles may offer a potentially viable system to be employed for both imaging and therapeutic purposes.
  •  
10.
  • Grishenkov, Dmitry, 1983-, et al. (författare)
  • On the acoustic properties of polymer-shell ultrasonic contrast agents.
  • 2008
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Polymer-shelled microbubbles have become the focus of intense research for their enhanced shelf life and demonstrated chemical versatility.  These are properties highly sought after in the ultrasonic contrast agents (UCAs) of the next generation, which will be engineered not only to enhance the contrast of ultrasound-based images, but also to function as carriers of drugs to be delivered locally.  Here, the results of an experimental investigation of three potentially new UCAs are presented.  These microbubbles are stabilized by thick poly (vinyl alcohol) shells.  These UCAs differ from each other in their dimensions and shell thickness (order of 0.5 microns).  Fundamental to their use as drug carrier is the knowledge of the pressure threshold at which the shell of these UCAs fractures.  Therefore, the dependence of this quantity on temperature, number of cycles of the incident pulse, nominal central frequency and pulse repetition frequency of the emitting transducer is examined.  The effect of using blood instead of deionized water is also considered.  The main conclusion to be drawn from these results is that their thick shell notwithstanding, these microbubbles begin to fracture at values of MI which can be acceptable in clinical applications.  This claim is supported also by images acquired by means of commercially available imaging systems.  Finally, these values of the pressure threshold are correlated with estimates of the shells’ visco-elastic constants obtained by fitting Church’s model to the frequency-dependent attenuation coefficient and phase velocity.  Open questions arising from this comparison are briefly discussed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 14

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy