SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Cornes Michael P) srt2:(2016)"

Search: WFRF:(Cornes Michael P) > (2016)

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Cornes, Michael P., et al. (author)
  • The role of European Federation of Clinical Chemistry and Laboratory Medicine Working Group for Preanalytical Phase in standardization and harmonization of the preanalytical phase in Europe
  • 2016
  • In: Annals of Clinical Biochemistry. - : SAGE Publications. - 0004-5632 .- 1758-1001. ; 53:5, s. 539-547
  • Research review (peer-reviewed)abstract
    • Patient safety is a leading challenge in healthcare and from the laboratory perspective it is now well established that preanalytical errors are the major contributor to the overall rate of diagnostic and therapeutic errors. To address this, the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for Preanalytical Phase (EFLM WG-PRE) was established to lead in standardization and harmonization of preanalytical policies and practices at a European level. One of the key activities of the WG-PRE is the organization of the biennial EFLM-BD conference on the preanalytical phase to provide a forum for National Societies (NS) to discuss their issues. Since 2012, a year after the first Preanalytical phase conference, there has been a rapid growth in the number of NS with a working group engaged in preanalytical phase activities and there are now at least 19 countries that have one. As a result of discussions with NS at the third conference held in March 2015 five key areas were identified as requiring harmonisation. These were test ordering, sample transport and storage, patient preparation, sampling procedures and management of unsuitable specimens. The article below summarises the work that has and will be done in these areas. The goal of this initiative is to ensure the EFLM WG-PRE produces work that meets the needs of the European laboratory medicine community. Progress made in the identified areas will be updated at the next preanalytical phase conference and show that we have produced guidance that has enhanced standardisation in the preanalytical phase and improved patient safety throughout Europe.
  •  
2.
  • Lippi, Giuseppe, et al. (author)
  • EFLM WG-Preanalytical phase opinion paper : local validation of blood collection tubes in clinical laboratories
  • 2016
  • In: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 54:5, s. 755-760
  • Journal article (peer-reviewed)abstract
    • The selection or procurement of blood collection devices in healthcare facilities is often an underestimated issue. This is probably due to different factors including the lack of knowledge of policymakers, hospital administrators and even laboratory managers about the importance of preanalytical quality and phlebotomy process, as well as to the absence of reliable guidelines or recommendations on how to precisely assess the quality of blood collection devices around the globe. With the awareness that a gap remains between manufacturers' and local validation of blood collection devices, the Working Group for Preanalytical Phase (WG-PRE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has drafted a consensus document aimed to provide a set of essential requisites, technical criteria (e.g. presence of physical defects, malfunctioning, safety problems) and clinical issues for supporting laboratory professionals in organization blood collection tubes tenders and validating new devices before local routine implementation. The laboratory professionals should also make sure that the tenders accurately and strictly define the responsibilities for validation experiments and the potential consequences in the case the validation outcome shows that tubes due not fulfill the expectations.
  •  
3.
  • van Dongen-Lases, Edmee C., et al. (author)
  • Patient identification and tube labelling - a call for harmonisation
  • 2016
  • In: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 54:7, s. 1141-1145
  • Journal article (peer-reviewed)abstract
    • Venous blood sampling (phlebotomy) is the most common invasive procedure performed in patient care. Guidelines on the correct practice of phlebotomy are available, including the H3-A6 guideline issued by the Clinical Laboratory Standards Institute (CLSI). As the quality of practices and procedures related to venous blood sample collection in European countries was unknown, the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase conducted an observational study in 12 European countries. The study demonstrated that the level of compliance of phlebotomy procedures with the CLSI H3-A6 guideline was unacceptably low, and that patient identification and tube labelling are amongst the most critical steps in need of immediate attention and improvement. The process of patient identification and tube labelling is an essential safety barrier to prevent patient identity mix-up. Therefore, the EFLM Working Group aims to encourage and support worldwide harmonisation of patient identification and tube labelling procedures in order to reduce the risk of preanalytical errors and improve patient safety. With this Position paper we wish to raise awareness and provide recommendations for proper patient and sample identification procedures.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view