SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Glauser T) srt2:(2015-2019)"

Search: WFRF:(Glauser T) > (2015-2019)

  • Result 1-4 of 4
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Wright, G. S., et al. (author)
  • The Mid-Infrared Instrument for the James Webb Space Telescope, II: Design and Build
  • 2015
  • In: Publications of the Astronomical Society of the Pacific. - : IOP Publishing. - 0004-6280 .- 1538-3873. ; 127:953, s. 595-611
  • Journal article (peer-reviewed)abstract
    • The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST) provides measurements over the wavelength range 5 to 28: 5 mu m. MIRI has, within a single "package," four key scientific functions: photometric imaging, coronagraphy, single-source low-spectral resolving power (R similar to 100) spectroscopy, and medium-resolving power (R similar to 1500 to 3500) integral field spectroscopy. An associated cooler system maintains MIRI at its operating temperature of
  •  
2.
  • Wells, M., et al. (author)
  • The Mid-Infrared Instrument for the James Webb Space Telescope, VI: The Medium Resolution Spectrometer
  • 2015
  • In: Publications of the Astronomical Society of the Pacific. - : IOP Publishing. - 0004-6280 .- 1538-3873. ; 127:953, s. 646-664
  • Journal article (peer-reviewed)abstract
    • We describe the design and performance of the Medium Resolution Spectrometer (MRS) for the JWST-MIRI instrument. The MRS incorporates four coaxial spectral channels in a compact opto-mechanical layout that generates spectral images over fields of view up to 7.7 x 7.7 '' in extent and at spectral resolving powers ranging from 1300 to 3700. Each channel includes an all-reflective integral field unit (IFU): an "image slicer" that reformats the input field for presentation to a grating spectrometer. Two 1024 x 1024 focal plane detector arrays record the output spectral images with an instantaneous spectral coverage of approximately one third of the full wavelength range of each channel. The full 5-28.5 mu m spectrum is then obtained by making three exposures using gratings and pass-band-determining filters that are selected using just two three-position mechanisms. The expected on-orbit optical performance is presented, based on testing of the MIRI Flight Model and including spectral and spatial coverage and resolution. The point spread function of the reconstructed images is shown to be diffraction limited and the optical transmission is shown to be consistent with the design expectations.
  •  
3.
  • Brandeker, Alexis, et al. (author)
  • Herschel detects oxygen in the beta Pictoris debris disk
  • 2016
  • In: Astronomy and Astrophysics. - : EDP Sciences. - 0004-6361 .- 1432-0746. ; 591
  • Journal article (peer-reviewed)abstract
    • The young star beta Pictoris is well known for its dusty debris disk produced through collisional grinding of planetesimals, kilometre-sized bodies in orbit around the star. In addition to dust, small amounts of gas are also known to orbit the star; this gas is likely the result of vaporisation of violently colliding dust grains. The disk is seen edge on and from previous absorption spectroscopy we know that the gas is very rich in carbon relative to other elements. The oxygen content has been more difficult to assess, however, with early estimates finding very little oxygen in the gas at a C/O ratio that is 20x higher than the cosmic value. A C/O ratio that high is difficult to explain and would have far-reaching consequences for planet formation. Here we report on observations by the far-infrared space telescope Herschel, using PACS, of emission lines from ionised carbon and neutral oxygen. The detected emission from C+ is consistent with that previously reported observed by the HIFI instrument on Herschel, while the emission from O is hard to explain without assuming a higher density region in the disk, perhaps in the shape of a clump or a dense torus required to sufficiently excite the O atoms. A possible scenario is that the C/O gas is produced by the same process responsible for the CO clump recently observed by the Atacama Large Millimeter/submillimeter Array in the disk and that the redistribution of the gas takes longer than previously assumed. A more detailed estimate of the C/O ratio and the mass of O will have to await better constraints on the C/O gas spatial distribution.
  •  
4.
  • Sloot, Frea, et al. (author)
  • Inventory of current EU paediatric vision and hearing screening programmes
  • 2015
  • In: Journal of Medical Screening. - : SAGE Publications. - 0969-1413 .- 1475-5793. ; 22:2, s. 55-64
  • Journal article (peer-reviewed)abstract
    • Objective: To examine the diversity in paediatric vision and hearing screening programmes in Europe. Methods: Themes for comparison of screening programmes derived from literature were used to compile three questionnaires on vision, hearing, and public health screening. Tests used, professions involved, age, and frequency of testing seem to influence sensitivity, specificity, and costs most. Questionnaires were sent to ophthalmologists, orthoptists, otolaryngologists, and audiologists involved in paediatric screening in all EU full-member, candidate, and associate states. Answers were cross-checked. Results: Thirty-nine countries participated; 35 have a vision screening programme, 33 a nation-wide neonatal hearing screening programme. Visual acuity (VA) is measured in 35 countries, in 71% of these more than once. First measurement of VA varies from three to seven years of age, but is usually before age five. At age three and four, picture charts, including Lea Hyvarinen, are used most; in children over four, Tumbling-E and Snellen. As first hearing screening test, otoacoustic emission is used most in healthy neonates, and auditory brainstem response in premature newborns. The majority of hearing testing programmes are staged; children are referred after 1–4 abnormal tests. Vision screening is performed mostly by paediatricians, ophthalmologists, or nurses. Funding is mostly by health insurance or state. Coverage was reported as >95% in half of countries, but reporting was often not first-hand. Conclusion: Largest differences were found in VA charts used (12), professions involved in vision screening (10), number of hearing screening tests before referral (1–4), and funding sources (8).
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-4 of 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view