SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Hetzel M.) srt2:(2015-2019)"

Search: WFRF:(Hetzel M.) > (2015-2019)

  • Result 1-10 of 12
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Eversmann, D., et al. (author)
  • New Method for a Continuous Determination of the Spin Tune in Storage Rings and Implications for Precision Experiments
  • 2015
  • In: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 115:9
  • Journal article (peer-reviewed)abstract
    • A new method to determine the spin tune is described and tested. In an ideal planar magnetic ring, the spin tune-defined as the number of spin precessions per turn-is given by nu(s) = gamma G (gamma is the Lorentz factor, G the gyromagnetic anomaly). At 970 MeV/c, the deuteron spins coherently process at a frequency of approximate to 120 kHz in the Cooler Synchrotron COSY. The spin tune is deduced from the up-down asymmetry of deuteron-carbon scattering. In a time interval of 2.6 s, the spin tune was determined with a precision of the order 10(-8), and to 1 x 10(-10) for a continuous 100 s accelerator cycle. This renders the presented method a new precision tool for accelerator physics; controlling the spin motion of particles to high precision is mandatory, in particular, for the measurement of electric dipole moments of charged particles in a storage ring.
  •  
2.
  • Hempelmann, N., et al. (author)
  • Phase measurement for driven spin oscillations in a storage ring
  • 2018
  • In: Physical Review Accelerators and Beams. - : American Physical Society. - 2469-9888. ; 21:4
  • Journal article (peer-reviewed)abstract
    • This paper reports the first simultaneous measurement of the horizontal and vertical components of the polarization vector in a storage ring under the influence of a radio frequency (rf) solenoid. The experiments were performed at the Cooler Synchrotron COSY in Julich using a vector polarized, bunched 0.97 GeV/c deuteron beam. Using the new spin feedback system, we set the initial phase difference between the solenoid field and the precession of the polarization vector to a predefined value. The feedback system was then switched off, allowing the phase difference to change over time, and the solenoid was switched on to rotate the polarization vector. We observed an oscillation of the vertical polarization component and the phase difference. The oscillations can be described using an analytical model. The results of this experiment also apply to other rf devices with horizontal magnetic fields, such as Wien filters. The precise manipulation of particle spins in storage rings is a prerequisite for measuring the electric dipole moment (EDM) of charged particles.
  •  
3.
  • Hempelmann, N., et al. (author)
  • Locking the Spin Precession in a Storage Ring
  • 2017
  • In: Physical Review Letters. - : American Physical Society. - 0031-9007 .- 1079-7114. ; 119:1
  • Journal article (peer-reviewed)abstract
    • This Letter reports the successful use of feedback from a spin polarization measurement to the revolution frequency of a 0.97 GeV= c bunched and polarized deuteron beam in the Cooler Synchrotron (COSY) storage ring in order to control both the precession rate (approximate to 121 kHz) and the phase of the horizontal polarization component. Real time synchronization with a radio frequency (rf) solenoid made possible the rotation of the polarization out of the horizontal plane, yielding a demonstration of the feedback method to manipulate the polarization. In particular, the rotation rate shows a sinusoidal function of the horizontal polarization phase (relative to the rf solenoid), which was controlled to within a 1 standard deviation range of sigma= 0.21 rad. The minimum possible adjustment was 3.7 mHz out of a revolution frequency of 753 kHz, which changes the precession rate by 26 mrad/s. Such a capability meets a requirement for the use of storage rings to look for an intrinsic electric dipole moment of charged particles.
  •  
4.
  • Saleev, A., et al. (author)
  • Spin tune mapping as a novel tool to probe the spin dynamics in storage rings
  • 2017
  • In: Physical Review Accelerators and Beams. - : American Physical Society. - 2469-9888. ; 20:7
  • Journal article (peer-reviewed)abstract
    • Precision experiments, such as the search for electric dipole moments of charged particles using storage rings, demand for an understanding of the spin dynamics with unprecedented accuracy. The ultimate aim is to measure the electric dipole moments with a sensitivity up to 15 orders in magnitude better than the magnetic dipole moment of the stored particles. This formidable task requires an understanding of the background to the signal of the electric dipole from rotations of the spins in the spurious magnetic fields of a storage ring. One of the observables, especially sensitive to the imperfection magnetic fields in the ring is the angular orientation of stable spin axis. Up to now, the stable spin axis has never been determined experimentally, and in addition, the JEDI collaboration for the first time succeeded to quantify the background signals that stem from false rotations of the magnetic dipole moments in the horizontal and longitudinal imperfection magnetic fields of the storage ring. To this end, we developed a new method based on the spin tune response of a machine to artificially applied longitudinal magnetic fields. This novel technique, called spin tune mapping, emerges as a very powerful tool to probe the spin dynamics in storage rings. The technique was experimentally tested in 2014 using polarized deuterons stored in the cooler synchrotron COSY, and for the first time, the angular orientation of the stable spin axis at two different locations in the ring has been determined to an unprecedented accuracy of better than 2.8 mu rad.
  •  
5.
  •  
6.
  • Al-Saffar, Anas, 1969-, et al. (author)
  • Parallel Changes in Harvey-Bradshaw Index, TNFα, and Intestinal Fatty Acid Binding Protein  in Response to Infliximab in Crohn’s Disease
  • 2017
  • In: Gastroenterology Research and Practice. - Egypt : Hindawi Publishing Corporation. - 1687-6121 .- 1687-630X. ; , s. 1-8
  • Journal article (peer-reviewed)abstract
    • Intestinal fatty acid binding protein (I-FABP) indicates barrier integrity. Aims: determine if I-FABP is elevated in active Crohn's disease (CD) and if I-FABP parallels anti-TNF alpha antibody (infliximab) induced lowering of TNF alpha and Harvey-Bradshaw Index (HBI) as potential indicator of mucosal healing. I-FABP distribution along human gut was determined. Serum from 10 CD patients collected during first three consecutive infliximab treatments with matched pretreatment and follow-up samples one week after each treatment and corresponding HBI data were analyzed. I-FABP reference interval was established from 31 healthy subjects with normal gut permeability. I-FABP and TNF alpha were measured by ELISA; CRP was measured by nephelometry. Healthy tissue was used for I-FABP immunohistochemistry. Pretreatment CD patient TNF alpha was 1.6-fold higher than in-house reference interval, while I-FABP was 2.5-fold higher, which lowered at follow-ups. Combining all 30 infusion/follow-up pairs also revealed changes in I-FABP. HBI followed this pattern; CRP declined gradually. I-FABP was expressed in epithelium of stomach, jejunum, ileum, and colon, with the highest expression in jejunum and ileum. I-FABP is elevated in active CD with a magnitude comparable to TNF alpha. Parallel infliximab effects on TNF alpha, HBI, and I-FABP were found. I-FABP may be useful as an intestine selective prognostic marker in CD.
  •  
7.
  • Diaz Tartera, Hetzel O., et al. (author)
  • [Not Available].
  • 2016
  • In: Läkartidningen. - 0023-7205 .- 1652-7518. ; 113
  • Journal article (peer-reviewed)abstract
    • The wireless motility-recording capsule, "SmartPill", is an ingested one-time use electronic capsule that measures gastrointestinal luminal pressure, pH and temperature along the whole gastrointestinal tract. The pH profile and the pressure patterns define the time at which the capsule moves from the stomach to the duodenum and from the ileum to the caecum, whereas changes in temperature define the times of ingestion and expulsion. The recordings from the wireless motility capsule are sent from a radio transmitter in the capsule to a receiver carried around the waist. Wireless motility recordings have several advantages over imaging and manometry that have been used previously. Primarily the simplicity by which motility recordings are done, as well as the tolerability for the patient and limited need of assistance are valuable aspects. The wireless motility capsule provides standardized measures of transit with relevant normal values for the clinical work-up of patients with motility disturbances.
  •  
8.
  • Diaz Tartera, Hetzel O., et al. (author)
  • Validation of SmartPill® wireless motility capsule for gastrointestinaltransit time : Intra-subject variability, software accuracy and comparison with video capsule endoscopy
  • 2017
  • In: Neurogastroenterology and Motility. - : Wiley. - 1350-1925 .- 1365-2982. ; 29:10
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: There is interest in ultimately combining endoscopy and motility assessments. Gastric emptying (GET), small bowel (SBTT), colon (CTT) and whole gut transit (WGTT) times are conveniently obtained by SmartPill® wireless motility capsule (WMC) that records luminal pH, temperature and pressure. Reproducibility within same subjects and accuracy of software derived times (MotiliGI® ) were investigated for diagnostic application. GET and SBTT were separately measured using video capsule endoscopy (VCE). The aim of this investigation was to assess same subject reproducibility of WMC, accuracy of software derived transit times and relate to Pillcam® SB (small bowel) VCE motility data.METHODS: Seventy three healthy adults ingested a 260 kcal mixed meal followed by WMC tests. Food intake was permitted after 6 hours. Regional transit data was obtained for GET, SBTT and CTT, the sum yielding WGTT. Nineteen subjects repeated WMC tests 2 or 4 weeks later; a separate 70 underwent VCE while fasted.KEY RESULTS: Visually derived data from WMC yielded GET 3.46±0.27, SBTT 5.15±0.21, CTT 20.76±1.19 and WGTT 29.53±1.28 hours (mean±SEM). Pearson's correlation coefficients (r) against software derived results were: GET 0.78 (P<.0001), SBTT 0.28 (P<.05), CTT 0.96 (P<.0001), WGTT 0.99 (P<.0001). VCE yielded lower GET (0.71±0.08 hours) and SBTT (4.15±0.13 hours).CONCLUSIONS AND INFERENCES: GET, SBTT, CTT and WGTT obtained by WMC are commensurate with literature values, including by other methods. Visually and software derived transit times have strongest correlations for CTT and WGTT. WMC yields longer GET and SBTT than VCE, perhaps due to meal related effects on motility.
  •  
9.
  • Engström, Johanna, et al. (author)
  • Comparison of fecal calprotectin and serum C-reactive protein in early prediction of outcome to infliximab induction therapy
  • 2019
  • In: Scandinavian Journal of Gastroenterology. - : TAYLOR & FRANCIS LTD. - 0036-5521 .- 1502-7708. ; 54:9, s. 1081-1088
  • Journal article (peer-reviewed)abstract
    • Background: Fecal calprotectin (FC) and serum C-reactive protein (CRP) are biomarkers of disease activity in Crohn's disease (CD) and ulcerative colitis (UC). We assessed FC, CRP, Harvey-Bradshaw index (HBi), partial Mayo Clinic Scoring (pMCS) and a cytokine panel during infliximab induction to predict therapy outcome.Methods: FC, CRP and clinical indices were evaluated in 123 (76 CD, 47 UC) patients before infliximab induction and after 12 weeks. Responders were monitored 48 weeks for an 'incident' (dosage increase, shortened dosage interval, surgery). Cutoff values for FC and CRP were obtained using receiver-operating characteristics (ROC). Disease progression was analyzed with Kaplan-Meier survivals, log-rank test and logistic regression for combined biomarkers. Cytokines were analyzed with Luminex multiplexing system.Results: Following infliximab, FC and CRP declined (p < .0001) along with HBi for CD and pMCS for UC. Simultaneously, IL-6 and TNF-alpha decreased, while IL-10 increased. Optimal FC ROC cutoff was 221 mu g/g (sensitivity 66%, specificity 67%, AUC 0.71) and CRP ROC cutoff 2.1 mg/L (sensitivity 54%, specificity 60%, AUC 0.58). In CD, FC > 221 mu g/g (p < .0001), but not CRP > 2.1 mg/L predicted an 'incident'. However, combined FC and CRP also predicted an 'incident' (p < .042). In UC, both FC > 221 mu g/g (p < .0005) and CRP > 2.1 mg/L (p = .0334) predicted 'incident', as did combined biomarkers (p < .005).Conclusions: Clinical disease activity is reduced by treatment with infliximab. In CD, persistently high FC, but not CRP, predict a treatment 'incident', whereas in UC both high FC and high CRP predict 'incident'. Combined FC and CRP values also predict an 'incident'.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view