1. |
|
|
2. |
- Andersson, Bengt-Åke, et al.
(author)
-
Use of a conductivity heat-flow meter in fluidised-bed boilers
- 1989
-
In: Transactions of the Institute of Measurement and Control. - : SAGE Publications. - 1477-0369 .- 0142-3312. ; 11:2, s. 108-112
-
Journal article (peer-reviewed)abstract
- The usefulness of a conductivity type of heat-flow meter for measurements in fluidised-bed boilers is investigated. The design and the calibration of the meter are described. Results from measurements of the local heat tranfer at the walls of fluidised-bed boilers are presented. An error analysis shows that the accuracy of the heat-flow meter is +-9%.
|
|
3. |
|
|
4. |
- Johnsson, Filip, 1960, et al.
(author)
-
Pressure distribution and particle concentration in bubbling fluidized beds
- 1989
-
In: Proc of the 6th International Conference on Fluidization. - 0816904596 ; 6, s. 419-426
-
Conference paper (peer-reviewed)abstract
- The expansion of and particle concentration in large-particle (>0.5 mm) bubbling beds, fluidized at high gas velocities (U-Umf>1 m/s) have been studied in a boiler with 10 m2 hot bed and in a cold two-dimensional bed. The significantly different behaviour of a freely bubbling versus a tube-filled bed at high gas velocity is demonstrated.
|
|