SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Lossius M. I.) srt2:(2015-2019)"

Search: WFRF:(Lossius M. I.) > (2015-2019)

  • Result 1-5 of 5
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Thomas, HS, et al. (author)
  • 2019
  • swepub:Mat__t
  •  
2.
  •  
3.
  • Ademuyiwa, Adesoji O., et al. (author)
  • Determinants of morbidity and mortality following emergency abdominal surgery in children in low-income and middle-income countries
  • 2016
  • In: BMJ Global Health. - : BMJ Publishing Group Ltd. - 2059-7908. ; 1:4
  • Journal article (peer-reviewed)abstract
    • Background: Child health is a key priority on the global health agenda, yet the provision of essential and emergency surgery in children is patchy in resource-poor regions. This study was aimed to determine the mortality risk for emergency abdominal paediatric surgery in low-income countries globally.Methods: Multicentre, international, prospective, cohort study. Self-selected surgical units performing emergency abdominal surgery submitted prespecified data for consecutive children aged <16 years during a 2-week period between July and December 2014. The United Nation's Human Development Index (HDI) was used to stratify countries. The main outcome measure was 30-day postoperative mortality, analysed by multilevel logistic regression.Results: This study included 1409 patients from 253 centres in 43 countries; 282 children were under 2 years of age. Among them, 265 (18.8%) were from low-HDI, 450 (31.9%) from middle-HDI and 694 (49.3%) from high-HDI countries. The most common operations performed were appendectomy, small bowel resection, pyloromyotomy and correction of intussusception. After adjustment for patient and hospital risk factors, child mortality at 30 days was significantly higher in low-HDI (adjusted OR 7.14 (95% CI 2.52 to 20.23), p<0.001) and middle-HDI (4.42 (1.44 to 13.56), p=0.009) countries compared with high-HDI countries, translating to 40 excess deaths per 1000 procedures performed.Conclusions: Adjusted mortality in children following emergency abdominal surgery may be as high as 7 times greater in low-HDI and middle-HDI countries compared with high-HDI countries. Effective provision of emergency essential surgery should be a key priority for global child health agendas.
  •  
4.
  • Mouthaan, B. E., et al. (author)
  • Current use of imaging and electromagnetic source localization procedures in epilepsy surgery centers across Europe
  • 2016
  • In: Epilepsia. - : Wiley. - 0013-9580. ; 57:5, s. 770-776
  • Journal article (peer-reviewed)abstract
    • Objective: In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers. Methods: A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations. Results: Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used. Significance: We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for highquality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods.
  •  
5.
  • Kobulashvili, T., et al. (author)
  • Current practices in long-term video-EEG monitoring services: A survey among partners of the E-PILEPSY pilot network of reference for refractory epilepsy and epilepsy surgery
  • 2016
  • In: Seizure-European Journal of Epilepsy. - : Elsevier BV. - 1059-1311. ; 38, s. 38-45
  • Journal article (peer-reviewed)abstract
    • Purpose: The European Union-funded E-PILEPSY network aims to improve awareness of, and accessibility to, epilepsy surgery across Europe. In this study we assessed current clinical practices in epilepsy monitoring units (EMUs) in the participating centers. Method: A 60-item web-based survey was distributed to 25 centers (27 EMUs) of the E-PILEPSY network across 22 European countries. The questionnaire was designed to evaluate the characteristics of EMUs, including organizational aspects, admission, and observation of patients, procedures performed, safety issues, cost, and reimbursement. Results: Complete responses were received from all (100%) EMUs surveyed. Continuous observation of patients was performed in 22 (81%) EMUs during regular working hours, and in 17 EMUs (63%) outside of regular working hours. Fifteen (56%) EMUs requested a signed informed consent before admission. All EMUs performed tapering/withdrawal of antiepileptic drugs, 14 (52%) prior to admission to an EMU. Specific protocols on antiepileptic drugs (AED) tapering were available in four (15%) EMUs. Standardized Operating Procedures (SOP) for the treatment of seizure clusters and status epilepticus were available in 16 (59%). Safety measures implemented by EMUs were: alarm seizure buttons in 21 (78%), restricted patient's ambulation in 19 (70%), guard rails in 16 (59%), and specially designated bathrooms in 7 (26%). Average costs for one inpatient day in EMU ranged between 100 and 2200 Euros. Conclusion: This study shows a considerable diversity in the organization and practice patterns across European epilepsy monitoring units. The collected data may contribute to the development and implementation of evidence-based recommended practices in LTM services across Europe. (C) 2016 The Authors. Published by Elsevier Ltd. on behalf of British Epilepsy Association.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-5 of 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view