SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Marks R.) srt2:(2005-2009)"

Search: WFRF:(Marks R.) > (2005-2009)

  • Result 1-9 of 9
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Aktas, A, et al. (author)
  • Inclusive production of D+, D-0, D-s(+) and D*(+) mesons in deep inelastic scattering at HERA
  • 2005
  • In: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044. ; 38:4, s. 447-459
  • Journal article (peer-reviewed)abstract
    • Inclusive production cross sections are measured in deep inelastic scattering at HERA for meson states composed of a charm quark and a light antiquark or the charge conjugate. The measurements cover the kinematic region of photon virtuality 2 < Q(2) < 100 GeV2, inelasticity 0.05 < y < 0.7, D meson transverse momenta p(t)( D) greater than or equal to 2.5 GeV and pseudorapidity |eta( D)| less than or equal to 1.5. The identification of the D-meson decays and the reduction of the combinatorial background profit from the reconstruction of displaced secondary vertices by means of the H1 silicon vertex detector. The production of charmed mesons containing the light quarks u, d and s is found to be compatible with a description in which the hard scattering is followed by a factorisable and universal hadronisation process.
  •  
2.
  • Aktas, A, et al. (author)
  • Measurement of prompt photon cross sections in photoproduction at HERA
  • 2005
  • In: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044. ; 38:4, s. 437-445
  • Journal article (peer-reviewed)abstract
    • Results are presented on the photoproduction of isolated prompt photons, inclusively and associated with jets, in the gammap center of mass energy range 142 < W < 266 GeV. The cross sections are measured for the transverse momentum range of the photons 5 < E. T < 10 GeV and for associated jets with E-T(jet) > 4.5 GeV. They are measured differentially as a function of E-T(gamma), E-T(jet), the pseudorapidities eta(gamma) and eta(jet) and estimators of the momentum fractions x(gamma) and x(p) of the incident photon and proton carried by the constituents participating in the hard process. In order to further investigate the underlying dynamics, the angular correlation between the prompt photon and the jet in the transverse plane is studied. Predictions by perturbative QCD calculations in next to leading order are about 30% below the inclusive prompt photon data after corrections for hadronisation and multiple interactions, but are in reasonable agreement with the results for prompt photons associated with jets. Comparisons with the predictions of the event generators PYTHIA and HERWIG are also presented.
  •  
3.
  • Aktas, A, et al. (author)
  • Search for light gravitinos in events with photons and missing transverse momentum at HERA
  • 2005
  • In: Physics Letters. Section B: Nuclear, Elementary Particle and High-Energy Physics. - : Elsevier BV. - 0370-2693. ; 616:1-2, s. 31-42
  • Journal article (peer-reviewed)abstract
    • A search for gravitinos produced in e(+/-)p collisions is performed using the H1 detector at HERA. The data were taken at a centre-of-mass energy of 319 GeV and correspond to an integrated luminosity of 64.3 pb(-1) for e(+)p collisions and 13.5 pb(-1) for e(-)p collisions. If R-parity is not conserved, the t-channel exchange of a selectron can produce a neutralino, which, in models where the gravitino is the lightest supersymmetric particle, subsequently decays into a photon and a light gravitino. The resulting event signature, which involves an isolated photon, a jet and missing transverse energy, is analysed for the first time at HERA. No deviation from the Standard Model is found. Exclusion limits on the cross section and on R-parity-violating Yukawa couplings are derived in a Gauge Mediated Supersymmetry Breaking scenario. The results are independent of the squark sector. Neutralinos and supersymmetric partners of the left-handed electron with masses up to 112 GeV and 164 GeV, respectively, can be ruled out at the 95% confidence level for R-parity-violating couplings lambda' equal to 1, in some parts of the parameter space of the considered model.
  •  
4.
  • Aktas, A, et al. (author)
  • Measurement of F-2(c(c)over-bar) and F-2(b(b)over-bar) at high Q(2) using the H1 vertex detector at HERA
  • 2005
  • In: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044. ; 40:3, s. 349-359
  • Journal article (peer-reviewed)abstract
    • Measurements are presented of inclusive charm and beauty cross sections in e(+)p collisions at HERA for values of photon virtuality Q(2) > 150 GeV2 and of inelasticity 0.1 < y < 0.7. The charm and beauty fractions are determined using a method based on the impact parameter, in the transverse plane, of tracks to the primary vertex, as measured by the H1 vertex detector. The data are divided into four regions in Q(2) and Bjorken x, and values for the structure functions F-2(c (c) over bar) and F-2(b (b) over bar) are obtained. The results are found to be compatible with the predictions of perturbative quantum chromodynamics.
  •  
5.
  • Marks, M. A. W., et al. (author)
  • Sodic pyroxene and sodic amphibole as potential reference materials for in situ lithium isotope determinations by SIMS
  • 2008
  • In: Geostandards and Geoanalytical Research. - 1639-4488. ; 32:3, s. 295-310
  • Journal article (peer-reviewed)abstract
    • Two large pegmatitic crystals of sodic pyroxene (aegirine) and sodic amphibole (arfvedsonite) from the agpaitic igneous Ilimaussaq Complex, south Greenland were found to be suitable as reference materials for in situ Li isotope determinations. Lithium concentrations determined by SIMS and micro-drilled material analysed by MC-ICP-MS generally agreed within analytical uncertainty. The arfvedsonite crystal was homogeneous with [Li] = 639 +/- 51 mu g g(-1) (2s, n = 69, MC-ICP-MS and SIMS results). The aegirine crystal shows strongly developed sector zoning, which is a common feature of aegirines. Using qualitative element mapping techniques (EPMA), the homogeneous core of the crystal was easily distinguished from the outermost sectors of the crystals. The core had a mean [Li] of 47.6 +/- 3.6 mu g g(-1) (2s, n = 33) as determined by SIMS. The seven micro-drilled regions measured by solution MC-ICP-MS returned slightly lower concentrations (41-46 mu g g(-1)), but still overlap with the SIMS data within uncertainty. Based on MC-ICP-MS and SIMS analyses, the variation in delta(7)Li was about 1 parts per thousand in each of the two crystals, which is smaller than that in widely used glass reference materials, making these two samples suitable to serve as reference materials. There was, however, a significant offset between the results of MC-ICP-MS and SIMS. The latter deviated from the MC-ICP-MS results by -6.0 +/- 1.9 parts per thousand (2s) for the amphibole and by -3.9 +/- 1.9 parts per thousand (2s) for the aegirine. This indicates the presence of a significant matrix effect in SIMS determinations of Li isotopes for amphibole and pyroxene relative to the basalt glasses used for calibration. Based on the MC-ICP-MS results, mean delta(7)Li values of +0.7 +/- 1.2 parts per thousand (2s, n = 10) for the arfvedsonite crystal and of -3.7 +/- 1.2 parts per thousand (2s, n = 7) for the core of the aegirine crystal were calculated. Adopting these values, SIMS users can correct for the specific IMF (instrumental mass fractionation) of the ion probe used. We propose that these two crystals serve as reference materials for in situ Li isotope determinations by SIMS and pieces of these two crystals are available from the first author upon request.
  •  
6.
  • Xie, Bin, et al. (author)
  • Thermal biosensor and microbiosensor techniques
  • 2008
  • In: Handbook of Biosensors and Biochips. - Chichester, UK : John Wiley & Sons, Ltd. - 9780470019054 - 9780470061565 ; 1, s. 639-657
  • Book chapter (peer-reviewed)abstract
    • This chapter describes principles and features of thermal biosensors and microbiosensors and includes a discussion of different thermal transducers. A number of instrumental concepts are described in detail from larger flow injection instruments to miniaturized devices and chip designs with thermal arrays. A thermal–electrochemical hybrid sensor is also presented. The chapter contains many descriptions of actual assays from different fields, such as process and in vivo monitoring, multianalyte determination, operation in organic solvents, and environmental analysis.
  •  
7.
  •  
8.
  •  
9.
  • Webb, Nicholas J A, et al. (author)
  • Multicentre prospective randomised trial of tacrolimus, azathioprine and prednisolone with or without basiliximab: two-year follow-up data.
  • 2009
  • In: Pediatric nephrology (Berlin, Germany). - : Springer Science and Business Media LLC. - 0931-041X .- 1432-198X. ; 24:1, s. 177-82
  • Journal article (peer-reviewed)abstract
    • A total of 192 children and adolescents undergoing renal transplantation were randomly chosen to receive tacrolimus, azathioprine and corticosteroids (TAS, n = 93) or tacrolimus, azathioprine, corticosteroids and two doses of basiliximab (TAS + B, n = 99). Six-month outcome data have previously been reported; this manuscript reports the 2-year data. Complete 2-year data were available on 164 (85.4%) of the original 192 patients. There was a single death in the TAS arm. Kaplan-Meier estimates of survival free of graft loss at 2 years were 94.9% in the TAS + B arm and 89.6% in the TAS arm [hazard ratio (HR) 0.52; 95% confidence interval (CI) 0.17 to 1.54, P = 0.23]. Estimates of survival free from rejection at 2 years were 75.2% in the TAS + B arm and 68.7% in the TAS arm (HR 0.81; 95% CI 0.46 to 1.40, P = 0.44). The mean estimated glomerular filtration rate (GFR) at 2 years, was 65.8 ml/min per 1.73 m(2) body surface area in the TAS arm and 66.7 ml/min per 1.73 m(2) in the TAS + B arm (P = 0.78). Blood pressure and cholesterol levels were similar in the two arms, and there was no evidence of a difference in the incidence of infection or malignancy. These data provide further evidence of a lack of benefit associated with the addition of basiliximab to a TAS regimen for European paediatric renal transplant recipients at low immunological risk.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-9 of 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view