SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Nathan A. M.) srt2:(2000-2004)"

Search: WFRF:(Nathan A. M.) > (2000-2004)

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Alcorn, J, et al. (author)
  • Basic instrumentation for Hall A at Jefferson Lab
  • 2004
  • In: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002. ; 522:3, s. 294-346
  • Journal article (peer-reviewed)abstract
    • The instrumentation in Hall A at the Thomas Jefferson National Accelerator Facility was designed to study electro-and photo-induced reactions at very high luminosity and good momentum and angular resolution for at least one of the reaction products. The central components of Hall A are two identical high resolution spectrometers, which allow the vertical drift chambers in the focal plane to provide a momentum resolution of better than 2 x 10(-4). A variety of Cherenkov counters, scintillators and lead-glass calorimeters provide excellent particle identification. The facility has been operated successfully at a luminosity well in excess of 10(38) CM-2 s(-1). The research program is aimed at a variety of subjects, including nucleon structure functions, nucleon form factors and properties of the nuclear medium. (C) 2003 Elsevier B.V. All rights reserved.
  •  
2.
  • Ronco, Claudio, et al. (author)
  • Blood flow distribution in sorbent beds : analysis of a new sorbent device for hemoperfusion
  • 2000
  • In: International Journal of Artificial Organs. - 0391-3988 .- 1724-6040. ; 23:2, s. 125-130
  • Journal article (peer-reviewed)abstract
    • A new polymer-based sorbent cartridge has been recently developed for enhancing middle molecule removal during hemodialysis. The cartridge (Betasorb, Renaltech, New York, USA) has been designed to be placed in series with the dialyzer in the blood circuit. It is therefore important to evaluate the distribution of flow into the blood compartment of the device in order to assess if the surface of the sorbent is utilized to the best. For this purpose, a special imaging technique was utilized. Cartridges were analyzed during a simulated in vitro circulation at 250 and 350 ml/min of blood flow and 25% and 40% hematocrit. Cartridges were placed in vertical position and a cross longitudinal section 1 cm thick was analyzed in sequence by a helical scanner. Dye was injected into the arterial inlet and the progressive distribution was evaluated by sequential densitometrical measures carried out automatically by the machine. The sequential images analyzed by the scanner demonstrated excellent distribution of the flow in the blood compartment with minimal difference between the central and the peripheral regions of the compartment. In particular the following flow velocity pattern could be observed under the different experimental conditions tested. We may conclude that the cartridge design is adequate and no channelling effects could be detected in the blood compartment. The flow distribution is slightly affected by changes in flow rate and hematocrit showing an optimal utilization of the available surface for molecule adsorption.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view