SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Rinaldi Christopher A.) srt2:(2019)"

Search: WFRF:(Rinaldi Christopher A.) > (2019)

  • Result 1-4 of 4
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Di Cori, Andrea, et al. (author)
  • Clinical impact of antithrombotic therapy in transvenous lead extraction complications : a sub-analysis from the ESC-EORP EHRA ELECTRa (European Lead Extraction ConTRolled) Registry
  • 2019
  • In: Europace. - : Oxford University Press. - 1099-5129 .- 1532-2092. ; 21:7, s. 1096-1105
  • Journal article (peer-reviewed)abstract
    • AIMS: A sub-analysis of the ESC-EHRA European Lead Extraction ConTRolled (ELECTRa) Registry to evaluate the clinical impact of antithrombotic (AT) on transvenous lead extraction (TLE) safety and efficacy.METHODS AND RESULTS: ELECTRa outcomes were compared between patients without AT therapy (No AT Group) and with different pre-operative AT regimens, including antiplatelets (AP), anticoagulants (AC), or both (AP + AC). Out of 3510 pts, 2398 (68%) were under AT pre-operatively. AT patients were older with more comorbidities (P < 0.0001). AT subgroups, defined as AP, AC, or AP + AC, were 1096 (31.2%), 985 (28%), and 317 (9%), respectively. Regarding AP patients, 1413 (40%) were under AP, 1292 (91%) with a single AP, interrupted in 26% about 3.8 ± 3.7 days before TLE. In total, 1302 (37%) patients were under AC, 881 vitamin K antagonist (68%), 221 (17%) direct oral anticoagulants, 155 (12%) low weight molecular heparin, and 45 (3.5%) unfractionated heparin. AC was 'interrupted without bridging' in 696 (54%) and 'interrupted with bridging' in 504 (39%) about 3.3 ± 2.3 days before TLE, and 'continued' in 87 (7%). TLE success rate was high in all subgroups. Only overall in-hospital death (1.4%), but not the procedure-related one, was higher in the AT subgroups (P = 0.0500). Age >65 years and New York Heart Association Class III/IV, but not AT regimens, were independent predictors of death for any cause. Haematomas were more frequent in AT subgroups, especially in AC 'continued' (P = 0.025), whereas pulmonary embolism in the No-AT (P < 0.01).CONCLUSIONS: AT minimization is safe in patients undergoing TLE. AT does not seem to predict death but identifies a subset of fragile patients with a worse in-hospital TLE outcome.
  •  
2.
  • Nof, Eyal, et al. (author)
  • Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal : an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry
  • 2019
  • In: Europace. - : Oxford University Press. - 1099-5129 .- 1532-2092. ; 21:12, s. 1876-1889
  • Journal article (peer-reviewed)abstract
    • AIMS: The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved.METHODS AND RESULTS: ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (<4 cm of lead left) in 88 (4.7%), and failed (>4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08-1.19), P < 0.0001 and OR 2.68 (1.22-5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04-0.95), P = 0.03 and OR 0.32 (0.13-0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01-4.16), P = 0.046].CONCLUSION: A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.
  •  
3.
  • Polewczyk, Anna, et al. (author)
  • Transvenous lead extraction procedures in women based on ESC-EHRA EORP European Lead Extraction ConTRolled ELECTRa registry : is female sex a predictor of complications?
  • 2019
  • In: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 21:12
  • Journal article (peer-reviewed)abstract
    • AIMS: Female sex is considered an independent risk factor of transvenous leads extraction (TLE) procedure. The aim of the study was to evaluate the effectiveness of TLE in women compared with men.METHODS AND RESULTS: A post hoc analysis of risk factors and effectiveness of TLE in women and men included in the ESC-EHRA EORP ELECTRa registry was conducted. The rate of major complications was 1.96% in women vs. 0.71% in men; P = 0.0025. The number of leads was higher in men (mean 1.89 vs. 1.71; P < 0.0001) with higher number of abandoned leads in women (46.04% vs. 34.82%; P < 0.0001). Risk factors of TLE differed between the sexes, of which the major were: signs and symptoms of venous occlusion [odds ratio (OR) 3.730, confidence interval (CI) 1.401-9.934; P = 0.0084], cumulative leads dwell time (OR 1.044, CI 1.024-1.065; P < 0.001), number of generator replacements (OR 1.029, CI 1.005-1.054; P = 0.0184) in females and the number of leads (OR 6.053, CI 2.422-15.129; P = 0.0001), use of powered sheaths (OR 2.742, CI 1.404-5.355; P = 0.0031), and white blood cell count (OR 1.138, CI 1.069-1.212; P < 0.001) in males. Individual radiological and clinical success of TLE was 96.29% and 98.14% in women compared with 98.03% and 99.21% in men (P = 0.0046 and 0.0098).CONCLUSION: The efficacy of TLE was lower in females than males, with a higher rate of periprocedural major complications. The reasons for this difference are probably related to disparities in risk factors in women, including more pronounced leads adherence to the walls of the veins and myocardium. Lead management may be key to the effectiveness of TLE in females.
  •  
4.
  • Segreti, Luca, et al. (author)
  • Procedural outcomes associated with transvenous lead extraction in patients with abandoned leads : an ESC-EHRA ELECTRa (European Lead Extraction ConTRolled) Registry Sub-Analysis.
  • 2019
  • In: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 21:4, s. 645-654
  • Journal article (peer-reviewed)abstract
    • Aims: The decision to abandon or extract superfluous leads remains controversial. We sought to compare procedural outcome of patients with and without abandoned leads undergoing transvenous lead extraction (TLE).Methods and results: An analysis of the ESC-EHRA European Lead Extraction ConTRolled ELECTRa registry was conducted. Patients were stratified into two groups based on the presence (Group 1) or absence (Group 2) of abandoned leads at the time for extraction. Out of 3508 TLE procedures, 422 patients (12.0%) had abandoned leads (Group 1). Group 1 patients were older and more likely to have implantable cardioverter-defibrillator devices, infection indication (78.8% vs. 49.8%), and vegetations (24.6% vs. 15.3%). Oldest lead dwelling time was longer in Group 1 (10.9 vs. 6.3 years) as was the number of extracted leads per patient (3.2 vs. 1.7). Manual traction failure (94.5% vs. 78.8%), powered sheath use (50.7% vs. 28.4%), and femoral approach were higher in Group 1 (P < 0.0001). Procedural success rate and clinical success (89.8% vs. 96.6%, P < 0.0001) were lower in Group 1. Major complication including deaths (5.5% vs. 2.3%, P = 0.0007) and procedure related major complications (3.3% vs. 1.4%, P = 0.0123) were higher in Group 1. The presence of abandoned leads at the time of TLE was an independent predictor of clinical failure [odds ratio (OR) 2.31, confidence interval (CI) 1.57-3.40] and complications [OR 1.69, CI 1.22-2.35]. receiver-operating characteristic curve analysis showed a dwell time threshold of 9 years for radiological failure and major complications.Conclusions: Previously abandoned leads at the time of TLE were associated with increased procedural complexity, clinical failure, and major complication, which may have important implications for future studies regarding managing of lead failures.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-4 of 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view