SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Salomon E) srt2:(2005-2009)"

Search: WFRF:(Salomon E) > (2005-2009)

  • Result 1-10 of 11
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Ageron, M., et al. (author)
  • The ANTARES optical beacon system
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 578:3, s. 498-509
  • Journal article (peer-reviewed)abstract
    • ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented. (C) 2007 Elsevier B.V. All rights reserved.
  •  
2.
  • Aguilar, J. A., et al. (author)
  • First results of the instrumentation line for the deep-sea ANTARES neutrino telescope
  • 2006
  • In: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 26:4-5, s. 314-324
  • Journal article (peer-reviewed)abstract
    • In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved.
  •  
3.
  • Aguilar, J. A., et al. (author)
  • The data acquisition system for the ANTARES neutrino telescope
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 570:1, s. 107-116
  • Journal article (peer-reviewed)abstract
    • The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described. (c) 2006 Elsevier B.V. All rights reserved.
  •  
4.
  • Ageron, M., et al. (author)
  • Studies of a full-scale mechanical prototype line for the ANTARES neutrino telescope and tests of a prototype instrument for deep-sea acoustic measurements
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 581:3, s. 695-708
  • Journal article (peer-reviewed)abstract
    • full-scale mechanical prototype line was deployed to a depth of 2500 m to test the leak tightness of the electronics containers and the pressure-resistant properties of an electromechanical cable under evaluation for use in the ANTARES deep-sea neutrino telescope. During a month-long immersion study, line parameter data were taken using miniature autonomous data loggers and shore-based optical time domain reflectometry. Details of the mechanical prototype line, the electromechanical cable and data acquisition are presented. Data taken during the immersion study revealed deficiencies in the pressure resistance of the electromechanical cable terminations at the entry points to the electronics containers. The improvements to the termination, which have been integrated into subsequent detection lines, are discussed. The line also allowed deep-sea acoustic measurements with a prototype hydrophone system. The technical setup of this system is described, and the first results of the data analysis are presented. (c) 2007 Elsevier B.V. All rights reserved.
  •  
5.
  • Aguilar, J A, et al. (author)
  • Study of large hemispherical photomultiplier tubes for the ANTARES neutrino telescope
  • 2005
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 555:1-2, s. 132-141
  • Journal article (peer-reviewed)abstract
    • The ANTARES neutrino telescope, to be immersed depth in the Mediterranean Sea, will consist of a three-dimensional matrix of 900 large area photomultiplier tubes housed in pressure-resistant glass spheres. The selection of the optimal photomultiplier was a critical step for the project and required an intensive phase of tests and developments carried out in close collaboration with the main manufacturers worldwide. This paper provides an overview of the tests performed by the collaboration and describes in detail the features of the photomultiplier tube chosen for ANTARES. (c) 2005 Elsevier B.V. All rights reserved.
  •  
6.
  •  
7.
  •  
8.
  • Benet, Leslie Z., et al. (author)
  • The use of BDDCS in classifying the permeability of marketed drugs
  • 2008
  • In: Pharmaceutical research. - : Springer. - 0724-8741 .- 1573-904X. ; 25:3, s. 483-488
  • Journal article (peer-reviewed)abstract
    • We recommend that regulatory agencies add the extent of drug metabolism (i.e., >or=90% metabolized) as an alternate method in defining Class 1 marketed drugs suitable for a waiver of in vivo studies of bioequivalence. That is, >or=90% metabolized is an additional methodology that may be substituted for >or=90% absorbed. We propose that the following criteria be used to define>or=90% metabolized for marketed drugs: Following a single oral dose to humans, administered at the highest dose strength, mass balance of the Phase 1 oxidative and Phase 2 conjugative drug metabolites in the urine and feces, measured either as unlabeled, radioactive labeled or nonradioactive labeled substances, account for >or=90% of the drug dosed. This is the strictest definition for a waiver based on metabolism. For an orally administered drug to be >or=90% metabolized by Phase 1 oxidative and Phase 2 conjugative processes, it is obvious that the drug must be absorbed. This proposal, which strictly conforms to the present>or=90% criteria, is a suggested modification to facilitate a number of marketed drugs being appropriately assigned to Class 1.
  •  
9.
  • Salomon, E., et al. (author)
  • Etching of silicon nanowires on Ag(110) by atomic hydrogen
  • 2009
  • In: Surface Science. - : Elsevier BV. - 0039-6028 .- 1879-2758. ; 603:23, s. 3350-3354
  • Journal article (peer-reviewed)abstract
    • Scanning Tunnelling Microscopy, High Resolution Electron Energy Loss Spectroscopy and High Resolution X-Ray Photoelectron Spectroscopy have been used to study the adsorption of atomic hydrogen onto Si nanowires grown on Ag(1 1 0). We demonstrate that the hydrogen strongly interacts with the Si nanowires modifying their structural and electronic properties. Hydrogen atoms etch the Si nanowires and eventually lead to their complete removal from the Ag(1 1 0) surface.
  •  
10.
  • Secin, Fernando P, et al. (author)
  • Multi-institutional Study of Symptomatic Deep Venous Thrombosis and Pulmonary Embolism in Prostate Cancer Patients Undergoing Laparoscopic or Robot-Assisted Laparoscopic Radical Prostatectomy
  • 2008
  • In: European Urology. - : Elsevier BV. - 1873-7560 .- 0302-2838. ; 53:1, s. 134-145
  • Journal article (peer-reviewed)abstract
    • OBJECTIVES: The true incidence of symptomatic deep venous thrombosis (DVT) and pulmonary embolism (PE) in patients undergoing laparoscopic radical prostatectomy is unknown. Our aim was to determine the incidence of symptomatic DVT and PE and the risk factors for these complications. METHODS: Fourteen surgeons from 13 referral institutions from both Europe and the United States provided retrospective data for all 5951 patients treated with laparoscopic radical prostatectomy (LRP), with or without robotic assistance, since the start of their institution's experience. Symptomatic DVT and PE within 90 d of surgery were regarded as venous thromboembolism (VTE). DVT was diagnosed mostly by Doppler ultrasound or contrast venography and PE by lung ventilation/perfusion scan or chest computed tomography or both. Statistical analysis included evaluation of incidence of symptomatic DVT and PE and risk factors as determined by exact methods and logistic regression. RESULTS: Of 5951 patients in the study, 31 developed symptomatic VTE (0.5%; 95% confidence interval [CI], 0.4%, 0.7%). Among patients with an event, 22 (71%) had DVT only, 4 had PE without identified DVT, and 5 had both. Two patients died of PE. Prior DVT (odds ratio [OR]=13.5; 95%CI, 1.4, 61.3), current tobacco smoking (OR=2.8; 95%CI, 1.0, 7.3), larger prostate volume (OR=1.18; 95%CI, 1.09, 1.28), patient re-exploration (OR=20.6; 95%CI, 6.6, 54.0), longer operative time (OR=1.05; 95%CI, 1.02, 1.09), and longer hospital stay (OR=1.05; 95%CI, 1.01, 1.09) were associated with VTE in univariate analysis. Neoadjuvant therapy, body mass index, surgical experience, surgical approach, pathologic stage, perioperative transfusion, and heparin administration were not significant predictors. CONCLUSIONS: The incidence of symptomatic VTE after LRP is low. These data do not support the administration of prophylactic heparin to all patients undergoing LRP, especially those without risk factors for VTE.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view