SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Soderqvist J.) srt2:(2000-2004)"

Search: WFRF:(Soderqvist J.) > (2000-2004)

  • Result 1-10 of 10
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Charlton, D. G., et al. (author)
  • System tests of radiation hard optical links for the ATLAS semiconductor tracker
  • 2000
  • In: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 443:03-feb, s. 430-446
  • Journal article (peer-reviewed)abstract
    • A prototype optical data and Timing Trigger and Control transmission system based on LEDs and PIN-diodes has been constructed. The system would be suitable in terms of radiation hardness and radiation length for use in the ATLAS SemiConductor Tracker. Bit error rate measurements were performed for the data links and for the links distributing the Timing, Trigger and Control data from the counting room to the front-end modules. The effects of cross-talk between the emitters and receivers were investigated. The advantages of using Vertical Cavity Surface Emitting Lasers (VCSELs) instead of LEDs are discussed.
  •  
2.
  • Andrieux, M. L., et al. (author)
  • Construction and test of the first two sectors of the ATLAS barrel liquid argon presampler
  • 2002
  • In: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 479:03-feb, s. 316-333
  • Journal article (peer-reviewed)abstract
    • The electromagnetic (e.m.) calorimeter of the ATLAS experiment for the Large Hadron Collider will be a sampling liquid argon accordion calorimeter. To achieve sufficient energy resolution, it is necessary to correct for the energy loss in the material upstream of the calorimeter. For this purpose, a separate presampler detector fixed on the inner face of the e.m. calorimeter, in the same cryostat, is being built by the ATLAS collaboration. Two presampler sectors have already been built and tested in their final version. The geometry of the detector and the various steps of its construction are reviewed. The hardware performance of the detector measured both at CERN and at the ISN-Grenoble (specific test bench) is discussed. It is concluded that the presampler will adequately fulfill its role for future operation at the CERN Large Hadron Collider.
  •  
3.
  • Akhmadaliev, S., et al. (author)
  • Results from a new combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter
  • 2000
  • In: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 449:3, s. 461-477
  • Journal article (peer-reviewed)abstract
    • A new combined test of an electromagnetic liquid argon accordion calorimeter and a hadronic scintillating-tile calorimeter was carried out at the CERN SPS. These devices are prototypes of the barrel calorimeter of the future ATLAS experiment at the LHC. The energy resolution of pions in the energy range from 10 to 300 GeV at an incident angle a of about 12 degrees is well described by the expression sigma/E = ((41.9 +/- 1.6)%/root E + (1.8 +/- 0.1)%)circle plus(1.8 +/- 0.1)/E, where E is in GeV. The response to electrons and muons was evaluated. Shower profiles, shower leakage and the angular resolution of hadronic showers were also studied. Results are compared with those from the previous beam test.
  •  
4.
  •  
5.
  • Akhmadaliev, S., et al. (author)
  • Hadron energy reconstruction for the ATLAS calorimetry in the framework of the non-parametrical method
  • 2002
  • In: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 480:03-feb, s. 508-523
  • Journal article (peer-reviewed)abstract
    • This paper discusses hadron energy reconstruction for the ATLAS barrel prototype combined calorimeter (consisting of a lead-liquid argon electromagnetic part and an iron-scintillator hadronic part) in the framework of the non-parametrical method. The non-parametrical method utilizes only the known e/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. Thus, this technique lends itself to an easy use in a first level trigger. The reconstructed mean values of the hadron energies are within +/-1% of the true values and the fractional energy resolution is [(58+/-3)%/rootE+(2.5+/-0.3)%]circle plus(1.7+/-0.2)/E. The value of the e/h ratio obtained for the electromagnetic compartment of the combined calorimeter is 1.74+/-0.04 and agrees with the prediction that e/h > 1.66 for this electromagnetic calorimeter. Results of a study of the longitudinal hadronic shower development are also presented. The data have been taken in the H8 beam line of the CERN SPS using pions of energies from 10 to 300 GeV.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view