SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Stefanescu I) srt2:(2015-2019)"

Search: WFRF:(Stefanescu I) > (2015-2019)

  • Result 1-10 of 10
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Hudson, Lawrence N, et al. (author)
  • The database of the PREDICTS (Projecting Responses of Ecological Diversity In Changing Terrestrial Systems) project
  • 2017
  • In: Ecology and Evolution. - : John Wiley & Sons. - 2045-7758. ; 7:1, s. 145-188
  • Journal article (peer-reviewed)abstract
    • The PREDICTS project-Projecting Responses of Ecological Diversity In Changing Terrestrial Systems (www.predicts.org.uk)-has collated from published studies a large, reasonably representative database of comparable samples of biodiversity from multiple sites that differ in the nature or intensity of human impacts relating to land use. We have used this evidence base to develop global and regional statistical models of how local biodiversity responds to these measures. We describe and make freely available this 2016 release of the database, containing more than 3.2 million records sampled at over 26,000 locations and representing over 47,000 species. We outline how the database can help in answering a range of questions in ecology and conservation biology. To our knowledge, this is the largest and most geographically and taxonomically representative database of spatial comparisons of biodiversity that has been collated to date; it will be useful to researchers and international efforts wishing to model and understand the global status of biodiversity.
  •  
2.
  • Anastasopoulos, M., et al. (author)
  • Multi-Grid detector for neutron spectroscopy : Results obtained on time-of-flight spectrometer CNCS
  • 2017
  • In: Journal of Instrumentation. - : IOP PUBLISHING LTD. - 1748-0221. ; 12:4
  • Journal article (peer-reviewed)abstract
    • The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of 3He detectors on an operational instrument. The demonstrator has an active area of 0.2 m2. It is specifically tailored to the specifications of CNCS. The detector was installed in June 2016 and has operated since then, collecting neutron scattering data in parallel to the He-3 detectors of CNCS. In this paper, we present a comprehensive analysis of this data, in particular on instrument energy resolution, rate capability, background and relative efficiency. Stability, gamma-ray and fast neutron sensitivity have also been investigated. The effect of scattering in the detector components has been measured and provides input to comparison for Monte Carlo simulations. All data is presented in comparison to that measured by the 3He detectors simultaneously, showing that all features recorded by one detector are also recorded by the other. The energy resolution matches closely. We find that the Multi-Grid is able to match the data collected by 3He, and see an indication of a considerable advantage in the count rate capability. Based on these results, we are confident that the Multi-Grid detector will be capable of producing high quality scientific data on chopper spectrometers utilising the unprecedented neutron flux of the ESS.
  •  
3.
  • Khaplanov, A., et al. (author)
  • Neutron beam monitors for the European spallation source
  • 2015
  • In: 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781467398626
  • Conference paper (peer-reviewed)abstract
    • The European Spallation Source (ESS), currently under construction in Lund, Sweden, will house a suite of 16 user instruments for neutron scattering experiments. The spallation source of the ESS will emit relatively long, 2.8 ms, neutron pulses with an integrated flux that will greatly exceed that of current facilities. This leads to both large advancements in instrument performance as well as to increased length and complexity of the beam delivery systems. The instruments will each be equipped with neutron beam monitors used for data normalisation and analysis, as well as commissioning and diagnostics. In this paper we present the requirements for beam monitors for the ESS and the strategy to meet these in a standardised approach. A large range of specifications in efficiency, dynamic range, time and position resolution, compatible materials are needed. A new feature for neutron beam monitors for some locations, is the ability to measure time profile of each source pulse individually. In general, event mode readout will be used for monitors, similarly to other neutron detectors at the facility. A selection of detectors based on different technologies will be available. Monitors will be integrated with beam lines and choppers in a way that allows to freely choose the type of monitor based on final requirements of an instrument. For this end, space for a standardised module, housing a monitor will be provided in conjunction with chopper assemblies and elsewhere on each beam line.
  •  
4.
  •  
5.
  • Birch, J., et al. (author)
  • Multi-Grid boron-10 detector for time-of-flight spectrometers in neutron scattering science
  • 2015
  • In: 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015. - : Institute of Electrical and Electronics Engineers (IEEE). - 9781467398626
  • Conference paper (peer-reviewed)abstract
    • The Multi-Grid (MG) detector has been introduced at ILL and developed by a collaboration between ILL, ESS and Linkoping University. This detector design addresses the severely decreased availability of He3, in particular for neutron scattering instruments with large-area detectors, such as time-of-flight neutron spectrometers at ESS and other facilities. The MG detector is based on thin converter films of boron-10 carbide arranged in layers orthogonal to the incoming neutrons. The design of the detector provides position resolution, efficiency competitive with He3 and a strong gamma rejection capability. This paper presents the MG large-area (2.4m2) demonstrator and the progress made in order to meet the needs of production of B4C-coated layers, mechanical parts and assembly on a scale similar to that of the final detectors for ESS. A particular effort was made to produce aluminium detector parts with a low alpha background, successfully reducing the background rate to acceptable levels. Following the IN5 demonstrator, a compact prototype has been designed in order to finalise the electronic readout to be used at the ESS instruments equipped with the MG.
  •  
6.
  • Clément, E., et al. (author)
  • Low-energy Coulomb excitation of Sr 96,98 beams
  • 2016
  • In: Physical Review C - Nuclear Physics. - 0556-2813. ; 94:5, s. 054326-
  • Journal article (peer-reviewed)abstract
    • The structure of neutron-rich Sr96,98 nuclei was investigated by low-energy safe Coulomb excitation of radioactive beams at the REX-ISOLDE facility, CERN, with the MINIBALL spectrometer. A rich set of transitional and diagonal E2 matrix elements, including those for non-yrast structures, has been extracted from the differential Coulomb-excitation cross sections. The results support the scenario of a shape transition at N=60, giving rise to the coexistence of a highly deformed prolate and a spherical configuration in Sr98, and are compared to predictions from several theoretical calculations. The experimental data suggest a significant contribution of the triaxal degree of freedom in the ground state of both isotopes. In addition, experimental information on low-lying states in Rb98 has been obtained.
  •  
7.
  • Clément, E, et al. (author)
  • Spectroscopic Quadrupole Moments in ^{96,98}Sr: Evidence for Shape Coexistence in Neutron-Rich Strontium Isotopes at N=60.
  • 2016
  • In: Physical Review Letters. - 1079-7114. ; 116:2
  • Journal article (peer-reviewed)abstract
    • Neutron-rich ^{96,98}Sr isotopes have been investigated by safe Coulomb excitation of radioactive beams at the REX-ISOLDE facility. Reduced transition probabilities and spectroscopic quadrupole moments have been extracted from the differential Coulomb excitation cross sections. These results allow, for the first time, the drawing of definite conclusions about the shape coexistence of highly deformed prolate and spherical configurations. In particular, a very small mixing between the coexisting states is observed, contrary to other mass regions where strong mixing is present. Experimental results have been compared to beyond-mean-field calculations using the Gogny D1S interaction in a five-dimensional collective Hamiltonian formalism, which reproduce the shape change at N=60.
  •  
8.
  • Stefanescu, I., et al. (author)
  • Neutron detectors for the ESS diffractometers
  • 2017
  • In: Journal of Instrumentation. - 1748-0221. ; 12:1
  • Journal article (peer-reviewed)abstract
    • The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the unprecedented high flux expected on the samples to be investigated in neutron diffraction or reflectometry experiments requires detectors that can handle high counting rates, while the investigation of sub-millimeter protein crystals will only be possible with large-area detectors that can achieve a position resolution as low as 200 μm. This has motivated an extensive research and development campaign to advance the state-of-the-art detector and to find new technologies that can reach maturity by the time the ESS will operate at full potential. This paper presents the key detector requirements for three of the Time-of-Flight (TOF) diffraction instrument concepts selected by the Scientific Advisory Committee to advance into the phase of preliminary engineering design. We discuss the detector technologies commonly employed at the existing similar instruments and their major challenges for ESS. The detector technologies selected by the instrument teams to collect the diffraction patterns are also presented. Analytical calculations, Monte-Carlo simulations, and real experimental data are used to develop a generic method to estimate the event rate in the diffraction detectors. We apply this method to make predictions for the future diffraction instruments, and thus provide additional information that can help the instrument teams with the optimisation of the detector designs.
  •  
9.
  •  
10.
  • Wrzosek-Lipska, K., et al. (author)
  • Electromagnetic properties of low-lying states in neutron-deficient Hg isotopes : Coulomb excitation of 182Hg, 184Hg, 186Hg and 188Hg
  • 2019
  • In: European Physical Journal A. - : Springer Science and Business Media LLC. - 1434-6001 .- 1434-601X. ; 55:8
  • Journal article (peer-reviewed)abstract
    • The neutron-deficient mercury isotopes serve as a classical example of shape coexistence, whereby at low energy near-degenerate nuclear states characterized by different shapes appear. The electromagnetic structure of even-mass 182-188 Hg isotopes was studied using safe-energy Coulomb excitation of neutron-deficient mercury beams delivered by the REX-ISOLDE facility at CERN. The population of 01,2+, 21,2+ and 41+ states was observed in all nuclei under study. Reduced E2 matrix elements coupling populated yrast and non-yrast states were extracted, including their relative signs. These are a sensitive probe of shape coexistence and may be used to validate nuclear models. The experimental results are discussed in terms of mixing of two different configurations and are compared with three different model calculations: the Beyond Mean Field model, the Interacting Boson Model with configuration mixing and the General Bohr Hamiltonian. Partial agreement with experiment was observed, hinting to missing ingredients in the theoretical descriptions.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view