SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Temple Robert) srt2:(2020-2023)"

Search: WFRF:(Temple Robert) > (2020-2023)

  • Result 1-2 of 2
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • McNamee, Robert, et al. (author)
  • The development of façade fire testing in Sweden
  • 2022
  • Reports (other academic/artistic)abstract
    • Façade fire testing has been high on the agenda worldwide due to the increased hazard of many occurrences of severe fire spread on façades. There is also international work going on to create a European standard for façade fire testing. In this context it is interesting to clarify what different national test methodologies are based on. This report is a review of the development that led to the Swedish standard for assessing fire performance of façades, SP Fire 105. The review starts from the development in the 1950s with assessing fire exposure from compartment fires and follows further development until 1990s. The fire exposure in the first edition of SP Fire 105 published 1985 was based on two test campaigns including external flames from room fires performed at Lund University during the late 70-ties and early 80-ties. In the early 90-ties the geometry of the air intake in the combustion chamber and the opening under the test specimen was slightly reduced leading to a lower effective thermal exposure of the façade than in the first edition of SP Fire 105. An important observation done already in the 1950s at the Swedish fire laboratory in Stockholm and in the late 1970s at Lund University was that the wind is influencing the test results when doing experiments outside.
  •  
2.
  • Sjöström, Johan, et al. (author)
  • External fire plumes from mass timber compartment fires—Comparison to test methods for regulatory compliance of façades
  • 2023
  • In: Fire and Materials. - : John Wiley and Sons Ltd. - 0308-0501 .- 1099-1018. ; 47, s. 433-
  • Journal article (peer-reviewed)abstract
    • Post-flashover fires inherently lead to external fire plumes, constituting a hazard for rapid fire spread over façades. As multi-storey mass timber buildings with internal visible timber surfaces become more common, there are concerns that such buildings would produce larger external plumes and hazards (assuming all other parameters equal). The literature reveals only indications of this, and how the actual exposure relates to different test methods for assessment is unknown. Here we utilise a series of full-scale mass timber compartment tests to quantify the exposure to the external façade. An incombustible external façade is instrumented with gauges at positions corresponding to reference data from several different assessment methods. The results show that there is an increase in plume duration, height, and temperatures when increasing the areas of exposed timber, but that this increase is less for normal- to large-opening compartments, than was previously seen in small-opening compartments. Also, normal variations in external wind speed have a larger influence on plume heights than the effect of doubling exposed timber surfaces. Test methods used for regulatory compliance differ significantly not only in exposure but also in pass/fail criteria. The proposed European large exposure method and the BS8414 method exhibit exposures on par with the severe end of what could be expected from mass timber compartments, whereas methods like SP Fire 105 and Lepir II produce significantly less severe plumes. However, the safety level is always a combination of exposure and assessment criteria. This data can help justify assessment criteria from a performance perspective. © 2023 The Authors. 
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2
Type of publication
reports (1)
journal article (1)
Type of content
other academic/artistic (1)
peer-reviewed (1)
Author/Editor
McNamee, Robert (2)
Anderson, Johan (2)
Temple, Alastair (2)
Sjöström, Johan (1)
Brandon, Daniel (1)
University
RISE (2)
Language
Swedish (1)
English (1)
Research subject (UKÄ/SCB)
Engineering and Technology (2)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view