SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Van Mieghem Nicolas M) srt2:(2020-2024)"

Search: WFRF:(Van Mieghem Nicolas M) > (2020-2024)

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Rosseel, Liesbeth, et al. (author)
  • Contemporary European practice in transcatheter aortic valve implantation: results from the 2022 European TAVI Pathway Registry.
  • 2023
  • In: Frontiers in cardiovascular medicine. - 2297-055X. ; 10
  • Journal article (peer-reviewed)abstract
    • A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume.The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe.Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice.Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%).Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.
  •  
2.
  • Kim, Won Keun, et al. (author)
  • Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice : one-yearresults of the ACURATE neo2 PMCF Study
  • 2024
  • In: EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. - 1969-6213. ; 20:1, s. 85-94
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).
  •  
3.
  • Stassen, Jan, et al. (author)
  • Managing Patients With Moderate Aortic Stenosis.
  • 2023
  • In: JACC. Cardiovascular imaging. - : Elsevier BV. - 1876-7591 .- 1936-878X.
  • Journal article (peer-reviewed)abstract
    • Current guidelines recommend that clinical surveillance for patients with moderate aortic stenosis (AS) and aortic valve replacement (AVR) may be considered if there is an indication for coronary revascularization. Recent observational studies, however, have shown that moderate AS is associated with an increased risk of cardiovascular events and mortality. Whether the increased risk of adverse events is caused by associated comorbidities, or to the underlying moderate AS itself, is incompletely understood. Similarly, which patients with moderate AS need close follow-up or could potentially benefit from early AVR is also unknown. In this review, the authors provide a comprehensive overview of the current literature on moderate AS. They first provide an algorithm that helps to diagnose moderate AS correctly, especially when discordant grading is observed. Although the traditional focus of AS assessment has been on the valve, it is increasingly acknowledged that AS is not only a disease of the aortic valve but also of the ventricle. The authors therefore discuss how multimodality imaging can help to evaluate the left ventricular remodeling response and improve risk stratification in patients with moderate AS. Finally, they summarize current evidence on the management of moderate AS and highlight ongoing trials on AVR in moderate AS.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view