SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Watsky Mitchell A.) srt2:(2008)"

Search: WFRF:(Watsky Mitchell A.) > (2008)

  • Result 1-3 of 3
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Liu, Wenguang, et al. (author)
  • Recombinant human collagen for tissue engineered corneal substitutes
  • 2008
  • In: Biomaterials. - : Elsevier BV. - 0142-9612 .- 1878-5905. ; 29:9, s. 1147-1158
  • Journal article (peer-reviewed)abstract
    • We successfully fabricated transparent, robust hydrogels as corneal substitutes from concentrated recombinant human type I and type III collagen solutions crosslinked with 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). White light transmission through these gels is comparable or superior to that of human corneas. Hydrogels from both type I and type III collagens supported in vitro epithelium and nerve over-growth. While both these biocompatible hydrogels have adequate tensile strength and elasticity for surgical manipulation, type III collagen hydrogels tended to be mechanically superior. Twelve-month post-implantation results of type I recombinant collagen-based corneal substitutes into mini-pigs showed retention of optical clarity, along with regeneration of corneal cells, nerves and tear film. For clinical use, implants based on fully characterized, recombinant human collagen eliminate the risk of pathogen transfer or xenogeneic immuno-responses posed by animal collagens. © 2007 Elsevier Ltd. All rights reserved.
  •  
2.
  • Merrett, Kimberley, et al. (author)
  • Tissue-engineered recombinant human collagen-based corneal substitutes for implantation : Performance of type I versus type III collagen
  • 2008
  • In: Investigative Ophthalmology and Visual Science. - : Association for Research in Vision and Ophthalmology (ARVO). - 0146-0404 .- 1552-5783. ; 49:9, s. 3887-3894
  • Journal article (peer-reviewed)abstract
    • PURPOSE. To compare the efficacies of recombinant human collagens types I and III as corneal substitutes for implantation. METHODS. Recombinant human collagen (13.7%) type I or III was thoroughly mixed with 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide. The final homogenous solution was either molded into sheets for in vitro studies or into implants with the appropriate corneal dimensions for transplantation into minipigs. Animals with implants were observed for up to 12 months after surgery. Clinical examinations of the cornea included detailed slit lamp biomicroscopy, in vivo confocal microscopy, and fundus examination. Histopathologic examinations were also performed on corneas harvested after 12 months. RESULTS. Both cross-linked recombinant collagens had refractive indices of 1.35, with optical clarity similar to that in human corneas. Their chemical and mechanical properties were similar, although RHC-III implants showed superior optical clarity. Implants into pig corneas over 12 months show comparably stable integration, with regeneration of corneal cells, tear film, and nerves. Optical clarity was also maintained in both implants, as evidenced by fundus examination. CONCLUSIONS. Both RHC-I and -III implants can be safely and stably integrated into host corneas. The simple cross-linking methodology and recombinant source of materials makes them potentially safe and effective future corneal matrix substitutes.
  •  
3.
  • Rafat, Mehrdad, et al. (author)
  • PEG-stabilized carbodiimide crosslinked collagen-chitosan hydrogels for corneal tissue engineering
  • 2008
  • In: Biomaterials. - : Elsevier BV. - 0142-9612 .- 1878-5905. ; 29:29, s. 3960-3972
  • Journal article (peer-reviewed)abstract
    • Implantable biomaterials that mimic the extracellular matrix (ECM) in key physical and physiological functions require components and microarchitectures that are carefully designed to maintain the correct balance between biofunctional and physical properties. Our goal was to develop hybrid polymer networks (HPN) that combine the bioactive features of natural materials and physical characteristics of synthetic ones to achieve synergy between the desirable mechanical properties of some components with the biological compatibility and physiological relevance of others. In this study, we developed collagen-chitosan composite hydrogels as corneal implants stabilized by either a simple carbodiimide cross-linker or a hybrid cross-linking system comprised of a long-range bi-functional cross-linker (e.g. poly(ethylene glycol) dibutyraldehyde (PEG-DBA)), and short-range amide-type cross-linkers (e.g. 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC), and N-hydroxysuccinimide (NHS)). Optimum hybrid hydrogel demonstrated significantly enhanced mechanical strength and elasticity by 100 and 20%, respectively, compared to its non-hybrid counterpart. It demonstrated excellent optical properties, optimum mechanical properties and suturability, and good permeability to glucose and albumin. It had excellent biocompatibility and when implanted into pig corneas for 12 months, allowed seamless host-graft integration with successful regeneration of host corneal epithelium, stroma, and nerves. © 2008 Elsevier Ltd. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-3 of 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view