SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(White Thomas) srt2:(2005-2009)"

Search: WFRF:(White Thomas) > (2005-2009)

  • Result 1-10 of 65
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Schael, S, et al. (author)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Research review (peer-reviewed)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Adcox, K, et al. (author)
  • Formation of dense partonic matter in relativistic nucleus-nucleus collisions at RHIC: Experimental evaluation by the PHENIX Collaboration
  • 2005
  • In: Nuclear Physics, Section A. - : Elsevier BV. - 0375-9474. ; 757:1-2, s. 184-283
  • Research review (peer-reviewed)abstract
    • Extensive experimental data from high-energy nucleus-nucleus collisions were recorded using the PHENIX detector at the Relativistic Heavy Ion Collider (RHIC). The comprehensive set of measurements from the first three years of RHIC operation includes charged particle multiplicities, transverse energy, yield ratios and spectra of identified hadrons in a wide range of transverse momenta (PT), elliptic flow, two-particle correlations, nonstatistical fluctuations, and suppression of particle production at high PT. The results are examined with an emphasis on implications for the formation of a new state of dense matter. We find that the state of matter created at RHIC cannot be described in terms of ordinary color neutral hadrons.
  •  
3.
  • Elsik, Christine G., et al. (author)
  • The Genome Sequence of Taurine Cattle : A Window to Ruminant Biology and Evolution
  • 2009
  • In: Science. - : American Association for the Advancement of Science (AAAS). - 0036-8075 .- 1095-9203. ; 324:5926, s. 522-528
  • Journal article (peer-reviewed)abstract
    • To understand the biology and evolution of ruminants, the cattle genome was sequenced to about sevenfold coverage. The cattle genome contains a minimum of 22,000 genes, with a core set of 14,345 orthologs shared among seven mammalian species of which 1217 are absent or undetected in noneutherian (marsupial or monotreme) genomes. Cattle-specific evolutionary breakpoint regions in chromosomes have a higher density of segmental duplications, enrichment of repetitive elements, and species-specific variations in genes associated with lactation and immune responsiveness. Genes involved in metabolism are generally highly conserved, although five metabolic genes are deleted or extensively diverged from their human orthologs. The cattle genome sequence thus provides a resource for understanding mammalian evolution and accelerating livestock genetic improvement for milk and meat production.
  •  
4.
  • Thyssen, Jacob Pontoppidan, et al. (author)
  • p-Phenylenediamine sensitization is more prevalent in central and southern European patch test centres than in Scandinavian: results from a multicentre study
  • 2009
  • In: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 60:6, s. 314-319
  • Journal article (peer-reviewed)abstract
    • Positive patch test reactions to p-phenylenediamine (PPD) are common. PPD is used in oxidative hair dyes and is also present in dark henna temporary 'tattoos'. Cross-sensitization to other contact allergens may occur. Because subjects sensitized to PPD are at risk of clinically severe reactions upon hair dyeing, there is a need for 'current' prevalence data on PPD sensitization. To compare PPD patch test results from dermatitis patients tested between 2003 and 2007 in 10 European patch test centres and to analyse the causes and determine relevance of positive PPD patch test reactions. Patch testing was performed using PPD (1% free base in petrolatum from Trolab (Almirall Hermal GmbH, Reinbeck, Germany) or Chemotechnique (Malmo, Sweden), equivalent to 0.090 mg/cm(2) in the TRUE (R) test from MEKOS Laboratories AS). Statistical analysis was performed using the chi-squared test. The weighted average prevalence was 4.6% among 21 515 patients. PPD sensitization occurred more often in centres located in Central and Southern Europe than in Scandinavian centres (odds ratio = 2.40; 95% confidence interval = 2.07-2.78). The overall proportion of positive patch test reactions to PPD that were registered as being of either current or 'past' relevance was high (weighted average 53.6% and 20.3%, respectively). Consumer hair dyeing was the most prominent cause of PPD sensitization (weighted average 41.8%). Furthermore, occupational hair dye exposure (10.6%) and cross-sensitization to textile dyes (12.6%) were frequently reported. PPD sensitization caused by exposure to hair dyes is frequent and remains a present problem for patients visiting contact dermatitis clinics, especially in patch test centres located in Central and Southern Europe.
  •  
5.
  • Abazov, V. M., et al. (author)
  • The upgraded DO detector
  • 2006
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 565:2, s. 463-537
  • Journal article (peer-reviewed)abstract
    • The DO experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics capabilities. We describe the new elements of the detector, including the silicon microstrip tracker, central fiber tracker, solenoidal magnet, preshower detectors, forward muon detector, and forward proton detector. The uranium/liquid -argon calorimeters and central muon detector, remaining from Run 1, are discussed briefly. We also present the associated electronics, triggering, and data acquisition systems, along with the design and implementation of software specific to DO.
  •  
6.
  • Agner, Tove, et al. (author)
  • Contact sensitisation in hand eczema patients-relation to subdiagnosis, severity and quality of life: a multi-centre study
  • 2009
  • In: Contact Dermatitis. - 0105-1873. ; 61:5, s. 291-296
  • Journal article (peer-reviewed)abstract
    • Background Contact sensitisation has been identified as a factor associated with poor prognosis for patients with hand eczema. Objectives To study implications of contact sensitisation with respect to severity, quality of life (QoL) and subdiagnosis of hand eczema. Methods The study was performed as a multi-centre, cross-sectional study from 10 European clinics. All patients were patch tested, and severity of hand eczema assessed by Hand Eczema Severity Index. A multi-variate analysis was performed to explore which factors influenced severity, QoL and sick leave. Results A total 416 patients were included, and 63% had contact sensitisation to one or more of the tested allergens. More women (66%) than men (51%) were sensitized. No significant association was found between sensitisation to specific allergens, disease severity, QoL or diagnostic subgroups. High age, male sex, atopic eczema and presence of contact sensitisation were independent risk factors for increased severity as measured by Hand Eczema Severity Index. Furthermore, the severity of hand eczema increased by the number of contact sensitisations detected (P = 0.023). High age and personal history of atopic eczema were independent risk factors for low QoL, as measured by Dermatology Life Quality Index, and atopic eczema as well as allergic contact dermatitis as subdiagnosis was associated with increased sick leave. Conclusion Diagnostic subgroups were not found to be related to specific allergens. Contact sensitisation was found to be a risk factor for increased severity of hand eczema, as did high age, male sex and atopic eczema.
  •  
7.
  • Agner, Tove, et al. (author)
  • Hand eczema severity and quality of life: a cross-sectional, multicentre study of hand eczema patients
  • 2008
  • In: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 59:1, s. 43-47
  • Journal article (peer-reviewed)abstract
    • Background and Objectives: Hand eczema is a chronic disease with negative impact on quality of life (QoL). In this study, QoL in hand eczema patients is assessed and related to age, sex, severity, and diagnostic subgroups. Methods: A total of 416 patients with hand eczema from 10 European patch test clinics participated in the study. Data on QoL were obtained from a self-administered questionnaire using the Dermatology Life Quality Index (DLQI). Severity was assessed by a scoring system (Hand Eczema Severity Index, HECSI) as well as frequency of eruptions and sick leave due to hand eczema. Results: No significant difference was found between males and females with respect to QoL [DLQI median values and 25/75 percentiles for males and females being 7.0 (3-14) and 8.0 (3-13), respectively], although males were more severely affected than females (P < 0.025). A significant positive correlation was found for hand eczema severity and age (P < 0.001), while no significant correlation was found for QoL and age. QoL was found increasingly reduced when sick leave was getting higher (P < 0.001). A statistically significant correlation between QoL (as measured by DLQI) and hand eczema severity as measured by HECSI was found (P < 0.001). No significant difference in QoL was found between diagnostic subgroups. Conclusions: QoL was found markedly negatively affected in hand eczema patients and was significantly correlated to disease severity. No significant difference in QoL was found between males and females, in spite of significantly more severe eczema in males, indicating that QoL in female patients is more easily affected.
  •  
8.
  • Price, Patricia E., et al. (author)
  • Dressing-related pain in patients with chronic wounds : an international patient perspective
  • 2008
  • In: International Wound Journal. - 1742-4801 .- 1742-481X. ; 5:2, s. 159-171
  • Journal article (peer-reviewed)abstract
    • This cross-sectional international survey assessed patients' perceptions of their wound pain. A total of 2018 patients (57% female) from 15 different countries with a mean age of 68.6 years (SD = 15.4) participated. The wounds were categorised into ten different types with a mean wound duration of 19.6 months (SD = 51.8). For 2018 patients, 3361 dressings/compression systems were being used, with antimicrobials being reported most frequently (n= 605). Frequency of wound-related pain was reported as 32.2%, 'never' or 'rarely', 31.1%, 'quite often' and 36.6%, 'most' or 'all of the time', with venous and arterial ulcers associated with more frequent pain (P= 0.002). All patients reported that 'the wound itself' was the most painful location (n= 1840). When asked if they experienced dressing-related pain, 286 (14.7%) replied 'most of the time' and 334 (17.2%) reported pain 'all of the time'; venous, mixed and arterial ulcers were associated with more frequent pain at dressing change (P < 0.001). Eight hundred and twelve (40.2%) patients reported that it took <1 hour for the pain to subside after a dressing change, for 449 (22.2%) it took 1-2 hours, for 192 (9.5%) it took 3-5 hours and for 154 (7.6%) patients it took more than 5 hours. Pain intensity was measured using a visual analogue scale (VAS) (0-100) giving a mean score of 44.5 (SD = 30.5, n= 1981). Of the 1141 who reported that they generally took pain relief, 21% indicated that they did not feel it was effective. Patients were asked to rate six symptoms associated with living with a chronic wound; 'pain' was given the highest mean score of 3.1 (n= 1898). In terms of different types of daily activities, 'overdoing things' was associated with the highest mean score (mean = 2.6, n= 1916). During the stages of the dressing change procedure; 'touching/handling the wound' was given the highest mean score of 2.9, followed by cleansing and dressing removal (n= 1944). One thousand four hundred and eighty-five (80.15%) patients responded that they liked to be actively involved in their dressing changes, 1141 (58.15%) responded that they were concerned about the long-term side-effects of medication, 790 (40.3%) of patient indicated that the pain at dressing change was the worst part of living with a wound. This study adds substantially to our knowledge of how patients experience wound pain and gives us the opportunity to explore cultural differences in more detail.
  •  
9.
  • Price, Patricia E., et al. (author)
  • Dressing-related pain in patients with chronic wounds : an international patient perspective
  • 2008
  • In: International Wound Journal. - : Wiley-Blackwell Publishing Ltd. - 1742-4801 .- 1742-481X. ; 5:2, s. 159-171
  • Journal article (peer-reviewed)abstract
    • This cross-sectional international survey assessed patients' perceptions of their wound pain. A total of 2018 patients (57% female) from 15 different countries with a mean age of 68.6 years (SD = 15.4) participated. The wounds were categorised into ten different types with a mean wound duration of 19.6 months (SD = 51.8). For 2018 patients, 3361 dressings/compression systems were being used, with antimicrobials being reported most frequently (n= 605). Frequency of wound-related pain was reported as 32.2%, 'never' or 'rarely', 31.1%, 'quite often' and 36.6%, 'most' or 'all of the time', with venous and arterial ulcers associated with more frequent pain (P= 0.002). All patients reported that 'the wound itself' was the most painful location (n= 1840). When asked if they experienced dressing-related pain, 286 (14.7%) replied 'most of the time' and 334 (17.2%) reported pain 'all of the time'; venous, mixed and arterial ulcers were associated with more frequent pain at dressing change (P < 0.001). Eight hundred andtwelve (40.2%) patients reported that it took <1 hour for the pain to subside after a dressing change, for 449 (22.2%) it took 1-2 hours, for 192 (9.5%) it took 3-5 hours and for 154 (7.6%) patients it took more than 5 hours. Pain intensity was measured using a visual analogue scale (VAS) (0-100) giving a mean score of 44.5 (SD = 30.5, n= 1981). Of the 1141 who reported that they generally took pain relief, 21% indicated that they did not feel it was effective. Patients were asked to rate six symptoms associated with living with a chronic wound; 'pain' was given the highest mean score of 3.1 (n= 1898). In terms of different types of daily activities, 'overdoing things' was associated with the highest mean score (mean = 2.6, n= 1916). During the stages of the dressing change procedure; 'touching/handling the wound' was given the highest mean score of 2.9, followed by cleansing and dressing removal (n= 1944). One thousand four hundred and eighty-five (80.15%) patients responded that they liked to be actively involved in their dressing changes, 1141 (58.15%) responded that they were concerned about the long-term side-effects of medication, 790 (40.3%) of patient indicated that the pain at dressing change was the worst part of living with a wound. This study adds substantially to our knowledge of how patients experience wound pain and gives us the opportunity to explore cultural differences in more detail.
  •  
10.
  • Abazov, V. M., et al. (author)
  • Search for a heavy resonance decaying into a Z plus jet final state in p(p)over-bar collisions at root s=1.96 TeV using the D0 detector
  • 2006
  • In: Physical Review D - Particles, Fields, Gravitation and Cosmology. - 1550-7998 .- 1550-2368. ; 74:1, s. 011104-
  • Journal article (peer-reviewed)abstract
    • We have searched for a heavy resonance decaying into a Z+jet final state in p (p) over bar collisions at a center of mass energy of 1.96 TeV at the Fermilab Tevatron collider using the D0 detector. No indication for such a resonance was found in a data sample corresponding to an integrated luminosity of 370 pb(-1). We set upper limits on the cross section times branching fraction for heavy resonance production at the 95% C.L. as a function of the resonance mass and width. The limits are interpreted within the framework of a specific model of excited quark production.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 65

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view