1.
  • Kardell, Martin, et al. (författare)
  • AUTOMATIC SEGMENTATION OF PELVIS FOR BRACHYTHERAPYOF PROSTATE
  • 2016
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 169:1-4, s. 398-404
  • Tidskriftsartikel (refereegranskat)abstract
    • Advanced model-based iterative reconstruction algorithms in quantitative computed tomography (CT) perform automatic segmentation of tissues to estimate material properties of the imaged object. Compared with conventional methods, these algorithms may improve quality of reconstructed images and accuracy of radiation treatment planning. Automatic segmentation of tissues is, however, a difficult task. The aim of this work was to develop and evaluate an algorithm that automatically segments tissues in CT images of the male pelvis. The newly developed algorithm (MK2014) combines histogram matching, thresholding, region growing, deformable model and atlas-based registration techniques for the segmentation of bones, adipose tissue, prostate and muscles in CT images. Visual inspection of segmented images showed that the algorithm performed well for the five analysed images. The tissues were identified and outlined with accuracy sufficient for the dual-energy iterative reconstruction algorithm whose aim is to improve the accuracy of radiation treatment planning in brachytherapy of the prostate.
  •  
2.
  • Kaveckyte, Vaiva, et al. (författare)
  • Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate Ir-192 brachytherapy sources
  • 2018
  • Ingår i: Medical physics (Lancaster). - : WILEY. - 0094-2405 .- 2473-4209. ; 45:1, s. 429-437
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Experimental dosimetry of high-dose-rate (HDR) Ir-192 brachytherapy (BT) sources is complicated due to high dose and dose-rate gradients, and softening of photon energy spectrum with depth. A single crystal synthetic diamond detector microDiamond (PTW 60019, Freiburg, Germany) has a small active volume, high sensitivity, direct readout, and nearly water-equivalent active volume. The purpose of this study was to evaluate the suitability of microDiamond detectors for the determination of absorbed dose to water around HDR Ir-192 BT sources. Three microDiamond detectors were used, allowing for the comparison of their properties. Methods: In-phantom measurements were performed using microSelectron and VariSource iX HDR Ir-192 BT treatment units. Their treatment planning systems (TPSs), Oncentra (v. 4.3) and BrachyVision (v. 13.6), respectively, were used to create irradiation plans for a cubic PMMA phantom with the microDiamond positioned at one of three source-to-detector distances (SDDs) (1.5, 2.5, and 5.5 cm) at a time. The source was stepped in increments of 0.5 cm over a total length of 6 cm to yield absorbed dose of 2 Gy at the nominal reference-point of the detector. Detectors were calibrated in Co-60 beam in terms of absorbed dose to water, and Monte Carlo (MC) calculated beam quality correction factors were applied to account for absorbed-dose energy dependence. Phantom correction factors were applied to account for differences in dimensions between the measurement phantom and a water phantom used for absorbed dose calculations made with a TPS. The same measurements were made with all three of the detectors. Additionally, dose-rate dependence and stability of the detectors were evaluated in Co-60 beam. Results: The percentage differences between experimentally determined and TPS-calculated absorbed doses to water were from -1.3% to +2.9%. The values agreed to within experimental uncertainties, which were from 1.9% to 4.3% (k = 2) depending on the detector, SDD and treatment delivery unit. No dose-rate or intrinsic energy dependence corrections were applied. All microDiamonds were comparable in terms of preirradiation dose, stability of the readings and energy response, and showed a good agreement. Conclusions: The results indicate that the microDiamond is potentially suitable for the determination of absorbed dose to water around HDR Ir-192 BT sources and may be used for independent verification of TPSs calculations, as well as for QA measurements of HDR Ir-192 BT treatment delivery units at clinical sites. (C) 2017 American Association of Physicists in Medicine
  •  
3.
  • Magnusson, Maria, et al. (författare)
  • DIRA-3D-a model-based iterative algorithm for accurate dual-energy dual-source 3D helical CT
  • 2019
  • Ingår i: Biomedical Engineering & Physics Express. - : IOP PUBLISHING LTD. - 2057-1976. ; 5:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Quantitative dual-energy computed tomography may improve the accuracy of treatment planning in radiation therapy. Of special interest are algorithms that can estimate material composition of the imaged object. One example of such an algorithm is the 2D model-based iterative reconstruction algorithm DIRA. The aim of this work is to extend this algorithm to 3D so that it can be used with cone-beams and helical scanning. In the new algorithm, the parallel FBP method was replaced with the approximate 3D FBP-based PI-method. Its performance was tested using a mathematical phantom consisting of six ellipsoids. The algorithm substantially reduced the beam-hardening artefact and the artefacts caused by approximate reconstruction after six iterations. Compared to Alvarez-Macovskis base material decomposition, DIRA-3D does not require geometrically consistent projections and hence can be used in dual-source CT scanners. Also, it can use several tissue-specific material bases at the same time to represent the imaged object.
  •  
4.
  • Malusek, Alexandr, et al. (författare)
  • A model-based iterative reconstruction algorithm DIRA using patient-specific tissue classification via DECT for improved quantitative CT in dose planning
  • 2017
  • Ingår i: Medical physics (Lancaster). - : WILEY. - 0094-2405. ; 44:6, s. 2345-2357
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To develop and evaluate-in a proof-of-concept configuration-a novel iterative reconstruction algorithm (DIRA) for quantitative determination of elemental composition of patient tissues for application to brachytherapy with low energy (amp;lt; 50 keV) photons and proton therapy. Methods: DIRA was designed as a model-based iterative reconstruction algorithm, which uses filtered backprojection, automatic segmentation and multimaterial tissue decomposition. The evaluation was done for a phantom derived from the voxelized ICRP 110 male phantom. Soft tissues were decomposed to the lipid, protein and water triplet, bones were decomposed to the compact bone and bone marrow doublet. Projections were derived using the Drasim simulation code for an axial scanning configuration resembling a typical DECT (dual-energy CT) scanner with 80 kV and Sn140 kV x-ray spectra. The iterative loop produced mono-energetic images at 50 and 88 keV without beam hardening artifacts. Different noise levels were considered: no noise, a typical noise level in diagnostic imaging and reduced noise level corresponding to tenfold higher doses. An uncertainty analysis of the results was performed using type A and B evaluations. The two approaches were compared. Results: Linear attenuation coefficients averaged over a region were obtained with relative errors less than 0.5% for all evaluated regions. Errors in average mass fractions of the three-material decomposition were less than 0.04 for no noise and reduced noise levels and less than 0.11 for the typical noise level. Mass fractions of individual pixels were strongly affected by noise, which slightly increased after the first iteration but subsequently stabilized. Estimates of uncertainties in mass fractions provided by the type B evaluation differed from the type A estimates by less than 1.5% for most cases. The algorithm was fast, the results converged after 5 iterations. The algorithmic complexity of forward polyenergetic projection calculation was much reduced by using material doublets and triplets. Conclusions: The simulations indicated that DIRA is capable of determining elemental composition of tissues, which are needed in brachytherapy with low energy (amp;lt; 50 keV) photons and proton therapy. The algorithm provided quantitative monoenergetic images with beam hardening artifacts removed. Its convergence was fast, image sharpness expressed via the modulation transfer function was maintained, and image noise did not increase with the number of iterations. c 2017 American Association of Physicists in Medicine
  •  
5.
  • Malusek, Alexandr, 1968-, et al. (författare)
  • ACCURATE KAP METER CALIBRATION AS A PREREQUISITE FOR OPTIMISATION IN PROJECTION RADIOGRAPHY
  • 2016
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press. - 0144-8420 .- 1742-3406. ; 169:1-4, s. 353-359
  • Tidskriftsartikel (refereegranskat)abstract
    • Modern X-ray units register the air kerma–area product, PKA, with a built-in KAP meter. Some KAP meters show an energydependent bias comparable with the maximum uncertainty articulated by the IEC (25 %), adversely affecting dose-optimisation processes. To correct for the bias, a reference KAP meter calibrated at a standards laboratory and two calibration methods described here can be used to achieve an uncertainty of <7 % as recommended by IAEA. A computational model of the reference KAP meter is used to calculate beam quality correction factors for transfer of the calibration coefficient at the standards laboratory, Q0, to any beam quality, Q, in the clinic. Alternatively, beam quality corrections are measured with an energy-independent dosemeter via a reference beam quality in the clinic, Q1, to beam quality, Q. Biases up to 35 % of built-in KAP meter readings were noted. Energy-dependent calibration factors are needed for unbiased PKA. Accurate KAP meter calibration as a prerequisite for optimisation in projection radiography.
  •  
6.
  • Örtenberg, Alexander, et al. (författare)
  • PARALLELISATION OF THE MODEL-BASED ITERATIVE RECONSTRUCTION ALGORITHM DIRA
  • 2016
  • Ingår i: Radiation Protection Dosimetry. - Oxford university press : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 169:1-4, s. 405-409
  • Tidskriftsartikel (refereegranskat)abstract
    • New paradigms for parallel programming have been devised to simplify software development on multi-core processors and many-core graphical processing units (GPU). Despite their obvious benefits, the parallelisation of existing computer programs is not an easy task. In this work, the use of the Open Multiprocessing (OpenMP) and Open Computing Language (OpenCL) frameworks is considered for the parallelisation of the model-based iterative reconstruction algorithm DIRA with the aim to significantly shorten the code’s execution time. Selected routines were parallelised using OpenMP and OpenCL libraries; some routines were converted from MATLAB to C and optimised. Parallelisation of the code with the OpenMP was easy and resulted in an overall speedup of 15 on a 16-core computer. Parallelisation with OpenCL was more difficult owing to differences between the central processing unit and GPU architectures. The resulting speedup was substantially lower than the theoretical peak performance of the GPU; the cause was explained.
  •  