SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Mirea L) srt2:(2016)"

Search: WFRF:(Mirea L) > (2016)

  • Result 1-6 of 6
Sort/group result
   
EnumerationReferenceCoverFind
1.
  •  
2.
  • Diakaki, M., et al. (author)
  • Towards the high-accuracy determination of the 238U fission cross section at the threshold region at CERN -€“ n_TOF
  • 2016
  • In: EPJ Web of Conferences. - : EDP Sciences. - 2100-014X.
  • Conference paper (peer-reviewed)abstract
    • The U-238 fission cross section is an international standard beyond 2 MeV where the fission plateau starts. However, due to its importance in fission reactors, this cross-section should be very accurately known also in the threshold region below 2 MeV. The U-238 fission cross section has been measured relative to the U-235 fission cross section at CERN - n_TOF with different detection systems. These datasets have been collected and suitably combined to increase the counting statistics in the threshold region from about 300 keV up to 3 MeV. The results are compared with other experimental data, evaluated libraries, and the IAEA standards.
  •  
3.
  •  
4.
  • Leal-Cidoncha, E., et al. (author)
  • Fission Fragment Angular Distribution measurements of 235U and 238U at CERN n_TOF facility
  • 2016
  • In: EPJ Web of Conferences. - : EDP Sciences. - 2100-014X.
  • Conference paper (peer-reviewed)abstract
    • Neutron-induced fission cross sections of U-238 and U-235 are used as standards in the fast neutron region up to 200 MeV. A high accuracy of the standards is relevant to experimentally determine other neutron reaction cross sections. Therefore, the detection efficiency should be corrected by using the angular distribution of the fission fragments (FFAD), which are barely known above 20 MeV. In addition, the angular distribution of the fragments produced in the fission of highly excited and deformed nuclei is an important observable to investigate the nuclear fission process. In order to measure the FFAD of neutron-induced reactions, a fission detection setup based on parallel-plate avalanche counters (PPACs) has been developed and successfully used at the CERN-n_TOF facility. In this work, we present the preliminary results on the analysis of new U-235(n,f) and U-238(n,f) data in the extended energy range up to 200 MeV compared to the existing experimental data.
  •  
5.
  • Gemmell, L., et al. (author)
  • Hypertensive disorders of pregnancy and outcomes of preterm infants of 24 to 28 weeks' gestation
  • 2016
  • In: Journal of Perinatology. - : Springer Science and Business Media LLC. - 0743-8346 .- 1476-5543. ; 36:12, s. 1067-1072
  • Journal article (peer-reviewed)abstract
    • OBJECTIVE: To examine the relationship between hypertensive disorders of pregnancy (HDPs) and mortality and major morbidities in preterm neonates born at 24 to 28 weeks of gestation.STUDY DESIGN: Using an international cohort, we retrospectively studied 27 846 preterm neonates born at 24 to 286 weeks of gestation during 2007 to 2010 from 6 national neonatal databases. The incidence of HDP was compared across countries, and multivariable logistic regression analyses were conducted to examine the association of HDP and neonatal outcomes including mortality to discharge, bronchopulmonary dysplasia, severe brain injury, necrotizing enterocolitis and treated retinopathy of prematurity.RESULTS: The incidence of HDP in the entire cohort was 13% (range 11 to 16% across countries). HDP was associated with reduced odds of mortality (adjusted odds ratio (aOR) 0.77; 95% confidence interval (CI) 0.67 to 0.88), severe brain injury (aOR 0.74; 95% CI 0.62 to 0.89) and treated retinopathy (aOR 0.82; 95% CI 0.70 to 0.96), but increased odds of bronchopulmonary dysplasia (aOR 1.16; 95% CI 1.05 to 1.27).CONCLUSIONS: In comparison with neonates born to mothers without HDP, neonates of HDP mothers had lower odds of mortality, severe brain injury and treated retinopathy, but higher odds of bronchopulmonary dysplasia. The impact of maternal HDP on newborn outcomes was inconsistent across outcomes and among countries; therefore, further international collaboration to standardize terminology, case definition and data capture is warranted.
  •  
6.
  • Bernard, Olivier, et al. (author)
  • Standardized evaluation system for left ventricular segmentation algorithms in 3D echocardiography.
  • 2016
  • In: IEEE Transactions on Medical Imaging. - : Institute of Electrical and Electronics Engineers (IEEE). - 0278-0062 .- 1558-254X. ; 35:4, s. 967-977
  • Journal article (peer-reviewed)abstract
    • Real-time 3D Echocardiography (RT3DE) has been proven to be an accurate tool for left ventricular (LV) volume assessment. However, identification of the LV endocardium remains a challenging task, mainly because of the low tissue/blood contrast of the images combined with typical artifacts. Several semi and fully automatic algorithms have been proposed for segmenting the endocardium in RT3DE data in order to extract relevant clinical indices, but a systematic and fair comparison between such methods has so far been impossible due to the lack of a publicly available common database. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms developed to segment the LV border in RT3DE. A database consisting of 45 multivendor cardiac ultrasound recordings acquired at different centers with corresponding reference measurements from 3 experts are made available. The algorithms from nine research groups were quantitatively evaluated and compared using the proposed online platform. The results showed that the best methods produce promising results with respect to the experts' measurements for the extraction of clinical indices, and that they offer good segmentation precision in terms of mean distance error in the context of the experts' variability range. The platform remains open for new submissions.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-6 of 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view