SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Petersen A. K.) srt2:(2005-2009)"

Search: WFRF:(Petersen A. K.) > (2005-2009)

  • Result 1-25 of 41
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Schael, S, et al. (author)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Research review (peer-reviewed)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  •  
3.
  •  
4.
  • Abate, E., et al. (author)
  • Combined performance tests before installation of the ATLAS Semiconductor and Transition Radiation Tracking Detectors
  • 2008
  • In: Journal of Instrumentation. - 1748-0221. ; 3
  • Journal article (peer-reviewed)abstract
    • The ATLAS (A Toroidal LHC ApparatuS) Inner Detector provides charged particle tracking in the centre of the ATLAS experiment at the Large Hadron Collider (LHC). The Inner Detector consists of three subdetectors: the Pixel Detector, the Semiconductor Tracker (SCT), and the Transition Radiation Tracker (TRT). This paper summarizes the tests that were carried out at the final stage of SCT+TRT integration prior to their installation in ATLAS. The combined operation and performance of the SCT and TRT barrel and endcap detectors was investigated through a series of noise tests, and by recording the tracks of cosmic rays. This was a crucial test of hardware and software of the combined tracker detector systems. The results of noise and cross-talk tests on the SCT and TRT in their final assembled configuration, using final readout and supply hardware and software, are reported. The reconstruction and analysis of the recorded cosmic tracks allowed testing of the offline analysis chain and verification of basic tracker performance parameters, such as efficiency and spatial resolution, in combined operation before installation.
  •  
5.
  •  
6.
  • Abat, E., et al. (author)
  • Study of the response of the ATLAS central calorimeter to pions of energies from 3 to 9 GeV
  • 2009
  • In: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002 .- 1872-9576. ; 607:2, s. 372-386
  • Journal article (peer-reviewed)abstract
    • A fully instrumented slice of the ATLAS central detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. in this paper, the response of the central calorimeters to pions with energies in the range between 3 and 9 GeV is presented. The linearity and the resolution of the combined calorimetry (electromagnetic and hadronic calorimeters) was measured and compared to the prediction of a detector simulation program using the toolkit Geant 4. (C) 2009 Elsevier B.V. All rights reserved.
  •  
7.
  • Abat, E., et al. (author)
  • The ATLAS TRT end-cap detectors
  • 2008
  • In: Journal of Instrumentation. - 1748-0221. ; 3
  • Journal article (peer-reviewed)abstract
    • The ATLAS TRT end-cap is a tracking drift chamber using 245,760 individual tubular drift tubes. It is a part of the TRT tracker which consist of the barrel and two end-caps. The TRT end-caps cover the forward and backward pseudo-rapidity region 1.0 < vertical bar eta vertical bar < 2.0, while the TRT barrel central eta region vertical bar eta vertical bar < 1.0. The TRT system provides a combination of continuous tracking with many measurements in individual drift tubes ( or straws) and of electron identification based on transition radiation from fibers or foils interleaved between the straws themselves. Along with other two sub-systems, namely the Pixel detector and Semi Conductor Tracker (SCT), the TRT constitutes the ATLAS Inner Detector. This paper describes the recently completed and installed TRT end-cap detectors, their design, assembly, integration and the acceptance tests applied during the construction.
  •  
8.
  • Abat, E., et al. (author)
  • The ATLAS Transition Radiation Tracker (TRT) proportional drift tube: design and performance
  • 2008
  • In: Journal of Instrumentation. - 1748-0221. ; 3:2
  • Journal article (peer-reviewed)abstract
    • A straw proportional counter is the basic element of the ATLAS Transition Radiation Tracker (TRT). Its detailed properties as well as the main properties of a few TRT operating gas mixtures are described. Particular attention is paid to straw tube performance in high radiation conditions and to its operational stability.
  •  
9.
  • Abat, E., et al. (author)
  • The ATLAS TRT barrel detector
  • 2008
  • In: Journal of Instrumentation. - 1748-0221. ; 3
  • Journal article (peer-reviewed)abstract
    • The ATLAS TRT barrel is a tracking drift chamber using 52,544 individual tubular drift tubes. It is one part of the ATLAS Inner Detector, which consists of three sub-systems: the pixel detector spanning the radius range 4 to 20 cm, the semiconductor tracker (SCT) from 30 to 52 cm, and the transition radiation tracker ( TRT) from 56 to 108 cm. The TRT barrel covers the central pseudo-rapidity region |eta| < 1, while the TRT endcaps cover the forward and backward eta regions. These TRT systems provide a combination of continuous tracking with many measurements in individual drift tubes ( or straws) and of electron identification based on transition radiation from fibers or foils interleaved between the straws themselves. This paper describes the recently-completed construction of the TRT Barrel detector, including the quality control procedures used in the fabrication of the detector.
  •  
10.
  • Abat, E., et al. (author)
  • The ATLAS TRT electronics
  • 2008
  • In: Journal of Instrumentation. - 1748-0221. ; 3:6
  • Journal article (peer-reviewed)abstract
    • The ATLAS inner detector consists of three sub-systems: the pixel detector spanning the radius range 4cm-20cm, the semiconductor tracker at radii from 30 to 52 cm, and the transition radiation tracker (TRT), tracking from 56 to 107 cm. The TRT provides a combination of continuous tracking with many projective measurements based on individual drift tubes (or straws) and of electron identification based on transition radiation from fibres or foils interleaved between the straws themselves. This paper describes the on and off detector electronics for the TRT as well as the TRT portion of the data acquisition (DAQ) system.
  •  
11.
  • Villa, Luisa L., et al. (author)
  • Quadrivalent vaccine against human papillomavirus to prevent high-grade cervical lesions
  • 2007
  • In: New England Journal of Medicine. - 0028-4793 .- 1533-4406. ; 356:19, s. 1915-1927
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Human papillomavirus types 16 (HPV-16) and 18 (HPV-18) cause approximately 70% of cervical cancers worldwide. A phase 3 trial was conducted to evaluate a quadrivalent vaccine against HPV types 6, 11, 16, and 18 (HPV-6/11/16/18) for the prevention of high-grade cervical lesions associated with HPV-16 and HPV-18. METHODS: In this randomized, double-blind trial, we assigned 12,167 women between the ages of 15 and 26 years to receive three doses of either HPV-6/11/16/18 vaccine or placebo, administered at day 1, month 2, and month 6. The primary analysis was performed for a per-protocol susceptible population that included 5305 women in the vaccine group and 5260 in the placebo group who had no virologic evidence of infection with HPV-16 or HPV-18 through 1 month after the third dose (month 7). The primary composite end point was cervical intraepithelial neoplasia grade 2 or 3, adenocarcinoma in situ, or cervical cancer related to HPV-16 or HPV-18. RESULTS: Subjects were followed for an average of 3 years after receiving the first dose of vaccine or placebo. Vaccine efficacy for the prevention of the primary composite end point was 98% (95.89% confidence interval [CI], 86 to 100) in the per-protocol susceptible population and 44% (95% CI, 26 to 58) in an intention-to-treat population of all women who had undergone randomization (those with or without previous infection). The estimated vaccine efficacy against all high-grade cervical lesions, regardless of causal HPV type, in this intention-to-treat population was 17% (95% CI, 1 to 31). CONCLUSIONS: In young women who had not been previously infected with HPV-16 or HPV-18, those in the vaccine group had a significantly lower occurrence of high-grade cervical intraepithelial neoplasia related to HPV-16 or HPV-18 than did those in the placebo group.
  •  
12.
  •  
13.
  • Norkus, A, et al. (author)
  • Use of a hydrocapillary dressing in the management of highly exuding ulcers; a comparative study
  • 2005
  • In: Journal of Wound Care. - 0969-0700. ; 14:9, s. 129-432
  • Journal article (peer-reviewed)abstract
    • Objective: To evaluate the safety and performance of Alione Hydrocapillary dressing (Coloplast A/S) in the management of highly exuding chronic venous leg ulcers and compare it with two hydropolymer dressings, Tielle and Tielle Plus (Johnson & Johnson). Method: A comparative clinical trial was conducted on 97 patients with an ankle brachial pressure index ?0.8 and a highly exuding leg ulcer. Ulcer duration was at least four weeks. Treatment continued until healing or for a maximum of 12 months. Results: There was no statistically significant difference in healing time or wound area reduction between the two treatment protocols. The test dressing (Alione Hydrocapillary) had better absorption capacity and was more comfortable for the patients than the comparator dressings (Tielle/Tielle Plus) and adhered less to the wound bed. Also, more patients preferred the test dressing to their previous treatment. Although severe leakage and maceration were observed more frequently in the comparator group compared with the test group, this was not statistically significant. Conclusion: Both treatment protocols were safe and effective in treating highly exuding chronic venous leg ulcers. The test dressing performed as well as or better than the comparator dressings for all study parameters and more patients preferred the test dressing to their previous dressing compared with the comparator dressings.
  •  
14.
  • Amundadottir, Laufey, et al. (author)
  • Genome-wide association study identifies variants in the ABO locus associated with susceptibility to pancreatic cancer.
  • 2009
  • In: Nature Genetics. - : Springer Science and Business Media LLC. - 1061-4036 .- 1546-1718. ; 41, s. 986-990
  • Journal article (peer-reviewed)abstract
    • We conducted a two-stage genome-wide association study of pancreatic cancer, a cancer with one of the lowest survival rates worldwide. We genotyped 558,542 SNPs in 1,896 individuals with pancreatic cancer and 1,939 controls drawn from 12 prospective cohorts plus one hospital-based case-control study. We conducted a combined analysis of these groups plus an additional 2,457 affected individuals and 2,654 controls from eight case-control studies, adjusting for study, sex, ancestry and five principal components. We identified an association between a locus on 9q34 and pancreatic cancer marked by the SNP rs505922 (combined P = 5.37 x 10(-8); multiplicative per-allele odds ratio 1.20; 95% confidence interval 1.12-1.28). This SNP maps to the first intron of the ABO blood group gene. Our results are consistent with earlier epidemiologic evidence suggesting that people with blood group O may have a lower risk of pancreatic cancer than those with groups A or B.
  •  
15.
  • Gauden, Magdalena, et al. (author)
  • Role of Solvent, pH, and Molecular Size in Excited-State Deactivation of Key Eumelanin Building Blocks: Implications for Melanin Pigment Photostability.
  • 2008
  • In: Journal of the American Chemical Society. - : American Chemical Society (ACS). - 1520-5126 .- 0002-7863. ; 130:50, s. 17038-17043
  • Journal article (peer-reviewed)abstract
    • Ultrafast time-resolved fluorescence spectroscopy has been used to investigate the excited-state dynamics of the basic eumelanin building block 5,6-dihydroxyindole-2-carboxylic acid (DHICA), its acetylated, methylated, and carboxylic ester derivatives, and two oligomers, a dimer and a trimer in the O-acetylated forms. The results show that (1) excited-state decays are faster for the trimer relative to the monomer; (2) for parent DHICA, excited-state lifetimes are much shorter in aqueous acidic medium (380 ps) as compared to organic solvent (acetonitrile, 2.6 ns); and (3) variation of fluorescence spectra and excited-state dynamics can be understood as a result of excited-state intramolecular proton transfer (ESIPT). The dependence on the DHICA oligomer size of the excited-state deactivation and its ESIPT mechanism provides important insight into the photostability and the photoprotective function of eumelanin. Mechanistic analogies with the corresponding processes in DNA and other biomolecules are recognized.
  •  
16.
  •  
17.
  •  
18.
  • Rockenbauer, Eszter, et al. (author)
  • SNP genotyping using microsphere-linked PNA and flow cytometric detection
  • 2005
  • In: Cytometry Part A. - : Wiley. - 1552-4930 .- 1552-4922. ; 64A:2, s. 80-86
  • Journal article (peer-reviewed)abstract
    • Background: Single nucleotide polymorphisms (SNPs) represent the most frequent form of genetic variations. Some of the most sensitive methods for SNP genotyping employ synthetic oligonucleotides, such as the peptide nucleic acid (PNA). We introduce a new method combining allele-specific hybridization, PNA technology, and flow cytometric detection. We tested the design by genotyping a Danish basal cell carcinoma cohort of 80 individuals for an A/C SNP in exon 6 of the XPD gene. Methods: Genomic DNA was amplified by a two-step polymerase chain reaction (PCR) in the presence of fluorescein-dyed primers and fluorescein-12-dUTP. The allele-specific PNA molecules were covalently coupled to carboxylated microspheres with and without rhodamine. Allele-specific hybridization between PCR products and immobilized PNA was carried out at 60 degrees C followed by flow cytometric detection. Results: We present a fully functional two-bead genotyping system based on PNA capture and flow cytometric detection used for the correct and fast regenotyping of a Danish basal cell carcinoma cohort. Conclusions: This new assay presents a simple, rapid, and robust method for SNP genotyping for laboratories equipped with a standard flow cytometer. Moreover, this system offers potential for multiplexing and will be operational for middle-scale genotyping.
  •  
19.
  •  
20.
  •  
21.
  •  
22.
  •  
23.
  •  
24.
  •  
25.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-25 of 41

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view