1.
  • Ask, Per, 1950-, et al. (author)
  • ECG Electrodes : A Study of Electrical and Mechanical Long-term Properties
  • 1979
  • In: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 23:2, s. 189-206
  • Journal article (peer-reviewed)abstract
    • The long-term properties of commercially available ECG-electrodes were studied by investigating the parameters: polarization potential, electrical impedance, adhesion, and skin reactions during a period of 7 days. As expected, the most stable polarization potentials were obtained for Ag/AgCl electrodes. Certain simple disposable electrodes showed large polarization potential variations. The most stable electrode impedance was obtained for disposable electrodes with stable adhesion and equipped with an electrode cup or similar. Unchanged adhesion and mechanical properties during the test period were shown by the disposable electrodes with a large self-adhesive collar.
  •  
2.
  • Hedenstierna, G, et al. (author)
  • Airway closure and distribution of inspired gas in the extremely obese, breathing spontaneously and during anaesthesia with intermittent positive pressure ventilation.
  • 1976
  • In: Acta Anaesthesiologica Scandinavica. - 0001-5172 .- 1399-6576. ; 20:4, s. 334-42
  • Journal article (peer-reviewed)abstract
    • Airway closure (closing capacity, CC), FRC, total efficiency of ventilation (lung clearance index, LCI) and distribution of inspired gas (nitrogen washout declay percentage, NWOD) were determined by nitrogen washout techniques and arterial PO2and PCO2 measured by standard electrodes in 10 extremely obese subjects, prior to an during anaesthesia and artifical ventilation. CC was normal, but because of small FRC, airway closure occurred within a tidal breath in 9 out of 10 subjects during spontaneous breathing, when awake. PO2 was reduced, the hypoxaemia correlating to the magnitude of airway closure. LCI was normal, but NWOD was borderline. During anaesthesia, CC was unaltered by FRC was further reduced, so that in nine subjects sirway closure occurred above FRC and tidal volume together. A marked increase in relative hypoxaemia was recorded. LCI and NWOD rose, indicating less efficient and less even ventilation. It is concluded that airway closure reasonably explains the marked hypoxaemia in obese subjects during anaesthesia, and that it may also be the reason for the uneven distribution of inspired gas.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-2 of 2
Type of publication
journal article (2)
Type of content
peer-reviewed (2)
Author/Editor
Ask, Per, 1950- (1)
Öberg, Åke (1)
Hedenstierna, G (1)
Ödman, S. (1)
Tenland, T. (1)
Skogh, M. (1)
show more...
Santesson, J (1)
Norlander, O (1)
show less...
University
Uppsala University (1)
Linköping University (1)
Language
English (2)
Research subject (UKÄ/SCB)
Medical and Health Sciences (1)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view