SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Erduran N.) srt2:(2010-2014)"

Search: WFRF:(Erduran N.) > (2010-2014)

  • Result 1-6 of 6
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Akkoyun, S., et al. (author)
  • AGATA - Advanced GAmma Tracking Array
  • 2012
  • In: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002 .- 0167-5087 .- 1872-9576. ; 668, s. 26-58
  • Journal article (peer-reviewed)abstract
    • The Advanced GAmma Tracking Array (AGATA) is a European project to develop and operate the next generation γ-ray spectrometer. AGATA is based on the technique of γ-ray energy tracking in electrically segmented high-purity germanium crystals. This technique requires the accurate determination of the energy, time and position of every interaction as a γ ray deposits its energy within the detector volume. Reconstruction of the full interaction path results in a detector with very high efficiency and excellent spectral response. The realisation of γ-ray tracking and AGATA is a result of many technical advances. These include the development of encapsulated highly segmented germanium detectors assembled in a triple cluster detector cryostat, an electronics system with fast digital sampling and a data acquisition system to process the data at a high rate. The full characterisation of the crystals was measured and compared with detector- response simulations. This enabled pulse-shape analysis algorithms, to extract energy, time and position, to be employed. In addition, tracking algorithms for event reconstruction were developed. The first phase of AGATA is now complete and operational in its first physics campaign. In the future AGATA will be moved between laboratories in Europe and operated in a series of campaigns to take advantage of the different beams and facilities available to maximise its science output. The paper reviews all the achievements made in the AGATA project including all the necessary infrastructure to operate and support the spectrometer. © 2011 Elsevier B.V. All rights reserved.
  •  
2.
  • Louchart, C., et al. (author)
  • Collective nature of low-lying excitations in Zn-70,Zn-72,Zn-74 from lifetime measurements using the AGATA spectrometer demonstrator
  • 2013
  • In: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 87:5
  • Journal article (peer-reviewed)abstract
    • Background: Neutron-rich nuclei with protons in the fp shell show an onset of collectivity around N=40. Spectroscopic information is required to understand the underlying mechanism and to determine the relevant terms of the nucleon-nucleon interaction that are responsible for the evolution of the shell structure in this mass region. Methods: We report on the lifetime measurement of the first 2(+) and 4(+) states in Zn-70,Zn-72 ,Zn-74 and the first 6(+) state in Zn-72 using the recoil distance Doppler shift method. The experiment was carried out at the INFN Laboratory of Legnaro with the AGATA demonstrator, first phase of the Advanced Gamma Tracking Array of highly segmented, high-purity germanium detectors coupled to the PRISMA magnetic spectrometer. The excited states of the nuclei of interest were populated in the deep inelastic scattering of a Ge-76 beam impinging on a U-238 target. Results: The maximum of collectivity along the chain of Zn isotopes is observed for Zn-72 at N=42. An unexpectedly long lifetime of 20(-5.2)(+1.8) ps was measured for the 4(+) state in Zn-74. Conclusions: Our results lead to small values of the B(E2;4(1)(+) -> 21(+))/B(E2;2(1)(+->)0(1)(+)) ratio for Zn-72,Zn-74, suggesting a significant noncollective contribution to these excitations. These experimental results are not reproduced by state-of-the-art microscopic models and call for lifetime measurements beyond the first 2(+) state in heavy zinc and nickel isotopes.
  •  
3.
  • Modamio, V., et al. (author)
  • Lifetime measurements in neutron-rich Co-63,Co-65 isotopes using the AGATA demonstrator
  • 2013
  • In: Physical Review C. Nuclear Physics. - 0556-2813 .- 1089-490X. ; 88:4, s. 044326-
  • Journal article (peer-reviewed)abstract
    • Lifetimes of the low-lying (11/2(-)) states in Co-63,Co-65 have been measured employing the recoil distance doppler shift method (RDDS) with the AGATA gamma-ray array and the PRISMA mass spectrometer. These nuclei were populated via a multinucleon transfer reaction by bombarding a U-238 target with a beam of Ni-64. The experimental B(E2) reduced transition probabilities for Co-63,Co-65 are well reproduced by large-scale shell-model calculations that predict a constant trend of the B(E2) values up to the N = 40 Co-67 isotope.
  •  
4.
  • Doncel, Maria, et al. (author)
  • Lifetime Measurements in Neutron-rich Cu Isotopes
  • 2013
  • In: Acta Physica Polonica B. - 0587-4254 .- 1509-5770. ; 44:3, s. 505-510
  • Journal article (peer-reviewed)abstract
    • The nuclear structure of neutron-rich nuclei close to the double-magic nucleus Ni-78 has been investigated by measuring the lifetime of excited states. In this contribution, it will be presented the lifetime of the J(pi) = 7/2(-) excited state at 981 keV of the Cu-71 isotope, measured using the AGATA Demonstrator coupled to the PRISMA spectrometer and the Koln plunger setup. This is the first time this combined setup has been used for a lifetime measurement.
  •  
5.
  • Jaworski, G., et al. (author)
  • Monte Carlo simulation of a single detector unit for the neutron detector array NEDA
  • 2012
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 673, s. 64-72
  • Journal article (peer-reviewed)abstract
    • A study of the dimensions and performance of a single detector of the future neutron detector array NEDA was performed by means of Monte Carlo simulations, using GEANT4. Two different liquid scintillators were evaluated: the hydrogen based BC501A and the deuterated BC537. The efficiency and the probability that one neutron will trigger a signal in more than one detector were investigated as a function of the detector size. The simulations were validated comparing the results to experimental measurements performed with two existing neutron detectors, with different geometries, based on the liquid scintillator BC501
  •  
6.
  • Luo, X. L., et al. (author)
  • Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)
  • 2014
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 767, s. 83-91
  • Journal article (peer-reviewed)abstract
    • A comparative study of the neutron-gamma discrimination performance of a liquid scintillator detector BC501A coupled to four different 5 in photomultiplier tubes (ET9390kb, R11833-100, XP4512 and R4144) was carried out Both the Charge Comparison method and the Integrated Rise-Time method were implemented digitally to discriminate between neutrons and gamma rays emitted by a Cf-252 source. In both methods, the neutron-gamma discrimination capabilities of the four photomultiplier tubes were quantitatively compared by evaluating their figure-of-merit values at different energy regions between 50 keVee and 1000 keVee. Additionally, the results were further verified qualitatively using time-of-flight to distinguish gamma rays and neutrons. The results consistently show that photomultiplier tubes R11833-100 and ET9390kb generally perform best regarding neutron-gamma discrimination with only slight differences in figure-of-merit values. This superiority can be explained by their relatively higher photoelectron yield, which indicates that a scintillator detector coupled to a photomultiplier tube with higher photoelectron yield tends to result in better neutron-gamma discrimination performance. The results of this work will provide reference for the choice of photomultiplier tubes for future neutron detector arrays like NEDA.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-6 of 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view