SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Grieco A.) srt2:(2020-2024)"

Search: WFRF:(Grieco A.) > (2020-2024)

  • Result 1-12 of 12
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • 2021
  • swepub:Mat__t
  •  
2.
  • 2021
  • swepub:Mat__t
  •  
3.
  • Bravo, L, et al. (author)
  • 2021
  • swepub:Mat__t
  •  
4.
  • Tabiri, S, et al. (author)
  • 2021
  • swepub:Mat__t
  •  
5.
  • Glasbey, JC, et al. (author)
  • 2021
  • swepub:Mat__t
  •  
6.
  •  
7.
  • Ash, G. I., et al. (author)
  • Establishing a Global Standard for Wearable Devices in Sport and Exercise Medicine: Perspectives from Academic and Industry Stakeholders
  • 2021
  • In: Sports Medicine. - : Springer Science and Business Media LLC. - 0112-1642 .- 1179-2035. ; 51, s. 2237-2250
  • Journal article (peer-reviewed)abstract
    • Millions of consumer sport and fitness wearables (CSFWs) are used worldwide, and millions of datapoints are generated by each device. Moreover, these numbers are rapidly growing, and they contain a heterogeneity of devices, data types, and contexts for data collection. Companies and consumers would benefit from guiding standards on device quality and data formats. To address this growing need, we convened a virtual panel of industry and academic stakeholders, and this manuscript summarizes the outcomes of the discussion. Our objectives were to identify (1) key facilitators of and barriers to participation by CSFW manufacturers in guiding standards and (2) stakeholder priorities. The venues were the Yale Center for Biomedical Data Science Digital Health Monthly Seminar Series (62 participants) and the New England Chapter of the American College of Sports Medicine Annual Meeting (59 participants). In the discussion, stakeholders outlined both facilitators of (e.g., commercial return on investment in device quality, lucrative research partnerships, and transparent and multilevel evaluation of device quality) and barriers (e.g., competitive advantage conflict, lack of flexibility in previously developed devices) to participation in guiding standards. There was general agreement to adopt Keadle et al.'s standard pathway for testing devices (i.e., benchtop, laboratory, field-based, implementation) without consensus on the prioritization of these steps. Overall, there was enthusiasm not to add prescriptive or regulatory steps, but instead create a networking hub that connects companies to consumers and researchers for flexible guidance navigating the heterogeneity, multi-tiered development, dynamicity, and nebulousness of the CSFW field.
  •  
8.
  •  
9.
  • Stilma, W, et al. (author)
  • Awake Proning as an Adjunctive Therapy for Refractory Hypoxemia in Non-Intubated Patients with COVID-19 Acute Respiratory Failure: Guidance from an International Group of Healthcare Workers
  • 2021
  • In: The American journal of tropical medicine and hygiene. - : American Society of Tropical Medicine and Hygiene. - 1476-1645 .- 0002-9637. ; 104:5, s. 1676-1686
  • Journal article (peer-reviewed)abstract
    • Non-intubated patients with acute respiratory failure due to COVID-19 could benefit from awake proning. Awake proning is an attractive intervention in settings with limited resources, as it comes with no additional costs. However, awake proning remains poorly used probably because of unfamiliarity and uncertainties regarding potential benefits and practical application. To summarize evidence for benefit and to develop a set of pragmatic recommendations for awake proning in patients with COVID-19 pneumonia, focusing on settings where resources are limited, international healthcare professionals from high and low- and middle-income countries (LMICs) with known expertise in awake proning were invited to contribute expert advice. A growing number of observational studies describe the effects of awake proning in patients with COVID-19 pneumonia in whom hypoxemia is refractory to simple measures of supplementary oxygen. Awake proning improves oxygenation in most patients, usually within minutes, and reduces dyspnea and work of breathing. The effects are maintained for up to 1 hour after turning back to supine, and mostly disappear after 6–12 hours. In available studies, awake proning was not associated with a reduction in the rate of intubation for invasive ventilation. Awake proning comes with little complications if properly implemented and monitored. Pragmatic recommendations including indications and contraindications were formulated and adjusted for resource-limited settings. Awake proning, an adjunctive treatment for hypoxemia refractory to supplemental oxygen, seems safe in non-intubated patients with COVID-19 acute respiratory failure. We provide pragmatic recommendations including indications and contraindications for the use of awake proning in LMICs.
  •  
10.
  • Grieco, Francesco, 1992, et al. (author)
  • Improvement of Odin/SMR water vapour and temperature measurements and validation of the obtained data sets
  • 2021
  • In: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 14:8, s. 5823-5857
  • Journal article (peer-reviewed)abstract
    • Its long photochemical lifetime makes H2O a good tracer for mesospheric dynamics. Temperature observations are also critical to study middle atmospheric dynamics. In this study, we present the reprocessing of 18 years of mesospheric H2O and temperature measurements from the Sub-Millimetre Radiometer (SMR) aboard the Odin satellite, resulting in a part of the SMR version 3.0 level 2 data set. The previous version of the data set showed poor accordance with measurements from other instruments, which suggested that the retrieved concentrations and temperature were subject to instrumental artefacts. Different hypotheses have been explored, and the idea of an underestimation of the singlesideband leakage turned out to be the most reasonable one. The value of the lowest transmission achievable has therefore been raised to account for greater sideband leakage, and new retrievals have been performed with the new settings. The retrieved profiles extend between 40-100 km altitude and cover the whole globe to reach 85° latitudes. A validation study has been carried out, revealing an overall better accordance with the compared instruments. In particular, relative differences in H2O mixing ratio are always in the ±20% range between 40 and 70 km and diverge at higher altitudes, while temperature absolute differences are within ±5K between 40-80 km and also diverge at higher altitudes.
  •  
11.
  • Palacin, M. R., et al. (author)
  • Roadmap on multivalent batteries
  • 2024
  • In: JPhys Energy. - 2515-7655. ; 6:3
  • Research review (peer-reviewed)abstract
    • Battery technologies based in multivalent charge carriers with ideally two or three electrons transferred per ion exchanged between the electrodes have large promises in raw performance numbers, most often expressed as high energy density, and are also ideally based on raw materials that are widely abundant and less expensive. Yet, these are still globally in their infancy, with some concepts (e.g. Mg metal) being more technologically mature. The challenges to address are derived on one side from the highly polarizing nature of multivalent ions when compared to single valent concepts such as Li+ or Na+ present in Li-ion or Na-ion batteries, and on the other, from the difficulties in achieving efficient metal plating/stripping (which remains the holy grail for lithium). Nonetheless, research performed to date has given some fruits and a clearer view of the challenges ahead. These include technological topics (production of thin and ductile metal foil anodes) but also chemical aspects (electrolytes with high conductivity enabling efficient plating/stripping) or high-capacity cathodes with suitable kinetics (better inorganic hosts for intercalation of such highly polarizable multivalent ions). This roadmap provides an extensive review by experts in the different technologies, which exhibit similarities but also striking differences, of the current state of the art in 2023 and the research directions and strategies currently underway to develop multivalent batteries. The aim is to provide an opinion with respect to the current challenges, potential bottlenecks, and also emerging opportunities for their practical deployment.
  •  
12.
  • Grieco, Francesco, 1992, et al. (author)
  • Recovery and validation of Odin/SMR long-term measurements of mesospheric carbon monoxide
  • 2020
  • In: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 13:9, s. 5013-5031
  • Journal article (peer-reviewed)abstract
    • The Sub-Millimetre Radiometer (SMR) on board the Odin satellite performs limb sounding measurements of the middle atmosphere to detect molecular emission from different species. Carbon monoxide (CO) is an important tracer of atmospheric dynamics at these altitudes, due to its long photochemical lifetime and high vertical concentration gradient. In this study, we have successfully recovered over 18 years of SMR observations, providing the only dataset to date being so extended in time and stretching out to the polar regions, with regards to satellite-measured mesospheric CO. This new dataset is part of the Odin/SMR version 3.0 level 2 data. Much of the level 1 dataset - except the October 2003 to October 2004 period - was affected by a malfunctioning of the phase-lock loop (PLL) in the front end used for CO observations. Because of this technical issue, the CO line could be shifted away from its normal frequency location, causing the retrieval to fail or leading to an incorrect estimation of the CO concentration. An algorithm was developed to locate the CO line and shift it to its correct location. Nevertheless, another artefact causing an underestimation of the concentration, i.e. a line broadening, stemmed from the PLL malfunctioning. This was accounted for by using a broader response function. The application of these corrections resulted in the recovery of a large amount of data that was previously being flagged as problematic and therefore not processed. A validation study has been carried out, showing how SMR CO volume mixing ratios are in general in good accordance with the other instruments considered in the study. Overall, the agreement is very good between 60 and 80 km altitude, with relative differences close to zero. A positive bias at low altitudes (50-60 km) up to +20% and a negative bias up to -20% at high altitudes (80-100 km) were found with respect to the comparison instruments.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-12 of 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view