SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Kihlberg Johan 1970 ) srt2:(2020-2022)"

Search: WFRF:(Kihlberg Johan 1970 ) > (2020-2022)

  • Result 1-5 of 5
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Bjällmark, Anna, et al. (author)
  • Radiology departmental policy compliance with Swedish guidelines regarding post-contrast acute kidney injury for examinations with iodinated contrast media
  • 2021
  • In: Radiography. - : Elsevier. - 1078-8174 .- 1532-2831. ; 27:4, s. 1058-1063
  • Journal article (peer-reviewed)abstract
    • INTRODUCTION: Guidelines concerning intravenous iodinated contrast media (CM) during computed tomography (CT) examinations are important to follow to minimize the risk for post-contrast acute kidney injury (PC-AKI). The purpose of this study was to investigate the radiology departmental policy compliance with Swedish guidelines concerning PC-AKI.METHODS: In February 2020, an electronic survey was distributed to the responsible radiographer at 41 radiology departments in all university hospitals and medium-sized hospitals in Sweden. The questions focused on routines around renal functional tests, individualized contrast administration and handling of patients with diabetes mellitus taking metformin.RESULTS: The response rate was 83%. Seventy-six percent (n = 26) of radiology departments calculated estimated glomerular filtration rate (eGFR) from serum creatinine prior to CM administration, but only 24% (n = 8) followed the recommendation to calculate eGFR from both serum creatinine and cystatin C. For acute/inpatients, 55% (n = 18) followed the recommendation that renal functional tests should be performed within 12 h before CM administration. For elective patients, 97% (n = 33) followed the recommendation to have eGFR newer than three months which is acceptable for patients with no history of disease that may have affected renal function. Approximately 80% of the radiology departments followed the recommendation that CM dose always should be individually adjusted to patient eGFR. Seventy-six percent (n = 26) followed the recommendation to continue with metformin at eGFR ≥ 45 ml/min.CONCLUSION: Compliance with the national guidelines was high regarding routines around renal functional tests, dose adjustment of CM and metformin discontinuation. Improvements can be made in using both cystatin C and serum creatinine for eGFR calculations as well as ensuring renal function tests within 12 h for acute/inpatients with acute disease that may affect renal function.IMPLICATIONS FOR PRACTICE: This study raises awareness of the importance of adhering to guidelines in healthcare. To have knowledge about the current level of compliance regarding PCI-AKI is important to maintain and develop effective clinical implementation of guidelines. The variation in practice seen in this study emphasizes the need of more effective implementation strategies to ensure adherence with best practice.
  •  
2.
  • El-Saadi, Walid, 1984-, et al. (author)
  • A head-to-head comparison of myocardial strain by fast-strain encoding and feature tracking imaging in acute myocardial infarction
  • 2022
  • In: Frontiers in Cardiovascular Medicine. - : Frontiers Media SA. - 2297-055X. ; 9
  • Journal article (peer-reviewed)abstract
    • BackgroundMyocardial infarction (MI) is a major cause of heart failure. Left ventricular adverse remodeling is common post-MI. Several studies have demonstrated a correlation between reduced myocardial strain and the development of adverse remodeling. Cardiac magnetic resonance (CMR) with fast-strain encoding (fast-SENC) or feature tracking (FT) enables rapid assessment of myocardial deformation. The aim of this study was to establish a head-to-head comparison of fast-SENC and FT in post-ST-elevated myocardial infarction (STEMI) patients, with clinical 2D speckle tracking echocardiography (2DEcho) as a reference. MethodsThirty patients treated with primary percutaneous coronary intervention for STEMI were investigated. All participants underwent CMR examination with late gadolinium enhancement, cine-loop steady-state free precession, and fast-SENC imaging using a 1.5T scanner as well as a 2DEcho. Global longitudinal strain (GLS), segmental longitudinal strain (SLS), global circumferential strain (GCS), and segmental circumferential strain (SCS) were assessed along with the MI scar extent. ResultsThe GCS measurements from fast-SENC and FT were nearly identical: the mean difference was 0.01 (2.5)% (95% CI - 0.92 to 0.95). For GLS, fast-SENC values were higher than FT, with a mean difference of 1.8 (1.4)% (95% CI 1.31-2.35). Tests of significance for GLS did not show any differences between the MR methods and 2DEcho. Average strain in the infarct-related artery (IRA) segments compared to the remote myocardium was significantly lower for the left anterior descending artery and right coronary artery culprits but not for the left circumflex artery culprits. Fast-SENC displayed a higher area under the curve for detecting infarcted segments than FT for both SCS and SLS. ConclusionGLS and GCS did not significantly differ between fast-SENC and FT. Both showed acceptable agreement with 2DEcho for longitudinal strain. Segments perfused by the IRA showed significantly reduced strain values compared to the remote myocardium. Fast-SENC presented a higher sensitivity and specificity for detecting infarcted segments than FT.
  •  
3.
  • Kihlberg, Johan, Medicine doktor, 1970-, et al. (author)
  • Clinical validation of three cardiovascular magnetic resonance techniques to measure strain and torsion in patients with suspected coronary artery disease
  • 2020
  • In: Journal of Cardiovascular Magnetic Resonance. - : BioMed Central. - 1097-6647 .- 1532-429X. ; 22:83
  • Journal article (peer-reviewed)abstract
    • BackgroundSeveral cardiovascular magnetic resonance (CMR) techniques can measure myocardial strain and torsion with high accuracy. The purpose of this study was to compare displacement encoding with stimulated echoes (DENSE), tagging and feature tracking (FT) for measuring circumferential and radial myocardial strain and myocardial torsion in order to assess myocardial function and infarct scar burden both at a global and at a segmental level.Method116 patients with a high likelihood of coronary artery disease (European SCORE > 15%) underwent CMR examination including cine images, tagging, DENSE and late gadolinium enhancement (LGE) in the short axis direction. In total, 97 patients had signs of myocardial disease and 19 had no abnormalities in terms of left ventricular (LV) wall mass index, LV ejection fraction, wall motion, LGE or a history of myocardial infarction. Thirty-four patients had myocardial infarct scar with a transmural LGE extent (transmurality) that exceeded 50% of the wall thickness in at least one segment. Global circumferential strain (GCS) and global radial strain (GRS) was analyzed using FT of cine loops, deformation of tag lines or DENSE displacement.ResultsDENSE and tagging both showed high sensitivity (82% and 71%) at a specificity of 80% for the detection of segments with > 50% LGE transmurality, and receiver operating characteristics (ROC) analysis showed significantly higher area under the curve-values (AUC) for DENSE (0.87) than for tagging (0.83, p < 0.001) and FT (0.66, p = 0.003). GCS correlated with global LGE when determined with DENSE (r = 0.41), tagging (r = 0.37) and FT (r = 0.15). GRS had a low but significant negative correlation with LGE; DENSE r = − 0.10, FT r = − 0.07 and tagging r = − 0.16. Torsion from DENSE and tagging had a weak correlation (− 0.20 and − 0.22 respectively) with global LGE.ConclusionCircumferential strain from DENSE detected segments with > 50% scar with a higher AUC than strain determined from tagging and FT at a segmental level. GCS and torsion computed from DENSE and tagging showed similar correlation with global scar size, while when computed from FT, the correlation was lower.
  •  
4.
  • Kihlberg, Johan, Medicine doktor, 1970-, et al. (author)
  • Magnetic resonance imaging incidents are severely underreported : a finding in a multicentre interview survey
  • 2022
  • In: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 32:1, s. 477-488
  • Journal article (peer-reviewed)abstract
    • Objectives: The purpose of this study was to develop a procedure to investigate the occurrence, character and causes of magnetic resonance (MR) imaging incidents. Methods: A semi-structured questionnaire was developed containing details such as safety zones, examination complexity, staff MR knowledge, staff categories, and implementation of EU directive 2013/35. We focused on formally reported incidents that had occurred during 2014–2019, and unreported incidents during one year. Thirteen clinical MR units were visited, and the managing radiographer was interviewed. Open questions were analysed using conventionally adopted content analysis. Results: Thirty-seven written reports for 5 years and an additional 12 oral reports for 1 year were analysed. Only 38% of the incidents were reported formally. Some of these incidents were catastrophic. Negative correlations were observed between the number of annual incidents (per scanner) and staff MR knowledge (Spearman’s rho − 0.41, p < 0.05) as well as the number of MR physicists per scanner (− 0.48, p < 0.05). It was notable that only half of the sites had implemented the EU directive. Quotes like ‘Burns are to be expected in MR’ and not even knowing the name of the incident reporting system suggested an inadequate safety culture. Finally, there was a desire among staff for MR safety education. Conclusions: MR-related incidents were greatly underreported, and some incidents could have had catastrophic outcomes. There is a great desire among radiographers to enhance the safety culture, but to achieve this, much more accessible education is required, as well as focused involvement of the management of the operations. Key Points: • Only one in three magnetic resonance–related incidents were reported. • Several magnetic resonance incidents could have led to catastrophic consequences. • Much increased knowledge about magnetic resonance safety is needed by radiologists and radiographers.
  •  
5.
  • Lundberg, Peter, 1958-, et al. (author)
  • Breast density is strongly associated with multiparametric magnetic resonance imaging biomarkers and pro-tumorigenic proteins in situ
  • 2022
  • In: British Journal of Cancer. - : Springer Nature. - 0007-0920 .- 1532-1827. ; 127, s. 2025-2033
  • Journal article (peer-reviewed)abstract
    • Background High mammographic density is an independent risk factor for breast cancer by poorly understood molecular mechanisms. Women with dense breasts often undergo conventional magnetic resonance imaging (MRI) despite its limited specificity, which may be increased by diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) and contrast. How these modalities are affected by breast density per se and their association with the local microenvironment are undetermined. Methods Healthy postmenopausal women attending mammography screen with extremely dense or entirely fatty breasts underwent multiparametric MRI for analyses of lean tissue fraction (LTF), ADC and perfusion dynamics. Microdialysis was used for extracellular proteomics in situ. Results Significantly increased LTF and ADC and delayed perfusion were detected in dense breasts. In total, 270 proteins were quantified, whereof 124 related to inflammation, angiogenesis, and cellular growth were significantly upregulated in dense breasts. Most of these correlated significantly with LTF, ADC and the perfusion data. Conclusions ADC and perfusion characteristics depend on breast density, which should be considered during the implementation of thresholds for malignant lesions. Dense and nondense breasts are two essentially different biological entities, with a pro-tumorigenic microenvironment in dense breasts. Our data reveal several novel pathways that may be explored for breast cancer prevention strategies.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-5 of 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view