SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Ulrich R.) srt2:(1995-1999)"

Search: WFRF:(Ulrich R.) > (1995-1999)

  • Result 1-9 of 9
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Edelson, R. A., et al. (author)
  • Multiwavelength observations of short-timescale variability in NGC 4151. IV. Analysis of multiwavelength continuum variability
  • 1996
  • In: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 470:1, s. 364-377377
  • Journal article (peer-reviewed)abstract
    • For pt.III see ibid., vol.470, no.1, p.349-63 (1996). Combines data from the three preceding papers in order to analyze the multi wave-band variability and spectral energy distribution of the Seyfert 1 galaxy NGC 4151 during the 1993 December monitoring campaign. The source, which was near its peak historical brightness, showed strong, correlated variability at X-ray, ultraviolet, and optical wavelengths. The strongest variations were seen in medium-energy (~1.5 keV) X-rays, with a normalized variability amplitude (NVA) of 24%. Weaker (NVA=6%) variations (uncorrelated with those at lower energies) were seen at soft gamma-ray energies of ~100 keV. No significant variability was seen in softer (0.1-1 keV) X-ray bands. In the ultraviolet/optical regime, the NVA decreased from 9% to 1% as the wavelength increased from 1275 to 6900 Aring. These data do not probe extreme ultraviolet (1200 Aring to 0.1 keV) or hard X-ray (250 keV) variability. The phase differences between variations in different bands were consistent with zero lag, with upper limits of lsim0.15 day between 1275 Aring and the other ultraviolet bands, lsim0.3 day between 1275 Aring and 1.5 keV, and lsim1 day between 1275 and 5125 Aring. These tight limits represent more than an order of magnitude improvement over those determined in previous multi-wave-band AGN monitoring campaigns. The ultraviolet fluctuation power spectra showed no evidence for periodicity, but were instead well fitted with a very steep, red power law (ales-2.5)
  •  
2.
  • Crenshaw, D. M., et al. (author)
  • Multiwavelength observations of short-timescale variability in NGC 4151. I. Ultraviolet observations
  • 1996
  • In: Astrophysical Journal. - : American Astronomical Society. - 0004-637X .- 1538-4357. ; 470:1, s. 322-335335
  • Journal article (peer-reviewed)abstract
    • Presents the results of an intensive ultraviolet monitoring campaign on the Seyfert 1 galaxy NGC 4151, as part of an effort to study its short-timescale variability over a broad range in wavelength. The nucleus of NGC 4151 was observed continuously with the International Ultraviolet Explorer for 9.3 days, yielding a pair of LWP and SWP spectra every ~70 minutes, and during 4 hr periods for 4 days prior to and 5 days after the continuous-monitoring period. The sampling frequency of the observations is an order of magnitude higher than that of any previous UV monitoring campaign on a Seyfert galaxy. The continuum fluxes in bands from 1275 to 2688 Aring went through four significant and well-defined ldquoeventsrdquo of duration 2-3 days during the continuous-monitoring period. The authors find that the amplitudes of the continuum variations decrease with increasing wavelength, which extends a general trend for this and other Seyfert galaxies to smaller timescales (i.e., a few days). The continuum variations in all the UV bands are simultaneous to within an accuracy of ~0.15 days, providing a strict constraint on continuum models. The emission-line light curves show only one major event during the continuous monitoring (a slow rise followed by a shallow dip) and do not correlate well with continuum light curves over the short duration of the campaign, because the timescale for continuum variations is apparently smaller than the response times of the emission lines
  •  
3.
  • Gustafsson, G, et al. (author)
  • The electric field and wave experiment for the Cluster mission
  • 1997
  • In: Space Science Reviews. - 0038-6308 .- 1572-9672. ; 79, s. 137-156
  • Journal article (peer-reviewed)abstract
    • The electric-field and wave experiment (EFW) on Cluster is designed to measure the electric-field and density fluctuations with sampling rates up to 36 000 samples s(-1). Langmuir probe sweeps can also be made to determine the electron density and temperature. The instrument has several important capabilities. These include (1) measurements of quasi-static electric fields of amplitudes lip to 700 mV m(-1) with high amplitude and time resolution, (2) measurements over short periods of time of up to five simualtaneous waveforms (two electric signals and three magnetic signals from the seach coil magnetometer sensors) of a bandwidth of 4 kHz with high time resolution, (3) measurements of density fluctuations in four points with high time resolution. Among the more interesting scientific objectives of the experiment are studies of nonlinear wave phenomena that result in acceleration of plasma as well as large- and small-scale interferometric measurements. By using four spacecraft for large-scale differential measurements and several Langmuir probes on one spacecraft for small-scale interferometry, it will be possible to study motion and shape of plasma structures on a wide range of spatial and temporal scales. This paper describes the primary scientific objectives of the EFW experiment and the technical capabilities of the instrument.
  •  
4.
  • Gustafsson, G, et al. (author)
  • The electric field and wave experiment for the Cluster mission
  • 1997
  • In: SPACE SCIENCE REVIEWS. - : KLUWER ACADEMIC PUBL. - 0038-6308. ; 79:1-2, s. 137-156
  • Journal article (peer-reviewed)abstract
    • The electric-field and wave experiment (EFW) on Cluster is designed to measure the electric-field and density fluctuations with sampling rates up to 36 000 samples s(-1). Langmuir probe sweeps can also be made to determine the electron density and tempera
  •  
5.
  • Ageberg, Eva, et al. (author)
  • Stabilometry and one-leg hop test have high test-retest reliability
  • 1998
  • In: Scandinavian Journal of Medicine & Science in Sports. - 1600-0838. ; 8:4, s. 198-202
  • Journal article (peer-reviewed)abstract
    • The purpose of this study was to investigate the reliability of repeated measurements and a possible learning or tiring process in single-limb stabilometry and one-leg hop test. An additional purpose was to study the correlation between different stabilometric variables. Seventy-five healthy subjects were examined twice with a median interval of 7 d, and with three consecutive measurements on each occasion. Single-limb stabilometry and one-leg hop test were found to have high reliability (ICC r = 0.68-0.83 and 0.96, respectively). The correlation between consecutive measurements was acceptable to high in stabilometry (r = 0.42-0.90, P = 0.002-P < 0.001) and high in the one-leg hop test (r = 0.91-0.97, P < 0.001). A learning process over time was observed. The correlation between the stabilometric variables was high (r = 0.73-0.95, P < 0.001).
  •  
6.
  • Fridén, Thomas, et al. (author)
  • Proprioception in the nearly extended knee. Measurements of position and movement in healthy individuals and in symptomatic anterior cruciate ligament injured patients
  • 1996
  • In: Knee Surgery, Sports Traumatology, Arthroscopy. - 1433-7347. ; 4:4, s. 217-224
  • Journal article (peer-reviewed)abstract
    • Proprioception of the knee was measured in 19 healthy individuals to evaluate whether there were any differences between extension and flexion movements from two different starting positions. The threshold before detecting a passive movement, visual estimation on a protractor of a passive change in position (30 degrees angular change) and active reproduction of the same angular change were registered. The reference population was tested twice to study normal variation and reproducibility, followed by the evaluation of 20 patients with chronic, symptomatic and unilateral anterior cruciate ligament (ACL)-deficient knees. In the normal population no differences were found between the right and the left leg, men and women, or measurements made at the first and at the second test occasion. The thresholds from a starting position of 20 degrees were lower for extension than for flexion. When comparing the thresholds for extension between the 20 degrees and the 40 degrees starting position, lower values were found in the more extended position. The thresholds for flexion were lower from the 40 degrees starting position than from the 20 degrees starting position. The active reproduction of an angular change of 30 degrees was more accurate during flexion (30 degrees-60 degrees) than during extension (60 degrees-30 degrees). There were no differences in the reproduction tests or in thresholds from the 40 degrees starting position between the patients and the normal group, but the patients had higher thresholds from the 20 degrees starting position, in movements towards both extension 1.0 degree (range 0.5 degree-12.0 degrees) and flexion 1.5 degrees (range 0.5 degree-10.0 degrees) than the normal group 0.75 degree (range 0.5 degree-2.25 degrees) (P = 0.01) and 1.0 degree (range 0.5 degree-3.0 degrees) (P = 0.06), respectively. Thus, information of passive movements in the nearly extended knee position was more sensitive towards extension than towards flexion in threshold tests and the sensitivity improved closer to full extension, which implies a logical joint protective purpose. In this nearly extended knee position, which is the basis for most weight-bearing activities, patients with symptomatic ACL-deficient knees had an impaired awareness in detecting a passive movement. There were no differences in the more flexed position or in the reproduction tests between the patients and the normal group, and reproduction tests in the present form seem less appropriate to use in the evaluation of ACL injuries.
  •  
7.
  •  
8.
  •  
9.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-9 of 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view