SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "(WFRF:(Piersanti L)) "

Search: (WFRF:(Piersanti L))

  • Result 1-10 of 12
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Golosio, B., et al. (author)
  • The FIRST experiment for nuclear fragmentation measurements at GSI
  • 2011
  • In: Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE. ; , s. 2277-2280
  • Conference paper (peer-reviewed)abstract
    • Nuclear fragmentation processes are relevant in different fields of physics concerning both basic research and applications. FIRST (Fragmentation of Ions Relevant for Space and Therapy) is an experiment aimed at the measurement of double differential cross sections (DDCS), with respect to kinetic energy and scattering polar angle, of nuclear fragmentation processes relevant for hadron therapy and for space radiation protection applications, in the energy range between 100 and 1000 MeV/u. The experiment was mounted at the GSI laboratories of Darmstadt, in Germany. A first data taking was performed in August 2011, using 400 MeV/u 12C on carbon and gold targets. In this work we present a description of the experimental apparatus and some figures from the data acquisition and from the preliminary work on data analysis
  •  
2.
  • Pavon-Rodriguez, J. A., et al. (author)
  • Characterisation of the n_TOF 20 m beam line at CERN with the new spallation target
  • 2023
  • In: 15TH INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, ND2022. - : EDP Sciences.
  • Conference paper (peer-reviewed)abstract
    • The n_TOF facility hosts CERN's pulsed neutron source, comprising two beam lines of different flight paths and one activation station. It is based on a proton beam delivered by the PS accelerator impinging on a lead spallation target. During Long Shutdown 2 (LS2) at CERN (2019-2021), a major upgrade of the spallation target was carried out in order to optimize the performances of the neutron beam. Therefore, the characteristics of n_TOF two experimental areas were investigated in detail. In this work, the focus is on the second experimental area (EAR2), located 20 m above the spallation target. Preliminary results of the neutron energy distribution and beam line energy resolution are presented, compared to previous experimental campaigns and Monte Carlo simulations with the FLUKA code. Moreover, preliminary results of the spatial beam profile measurements are shown.
  •  
3.
  •  
4.
  • Alcayne, V., et al. (author)
  • A segmented total energy detector (sTED) for (n, gamma) cross section measurements at n_TOF EAR2
  • 2023
  • In: 15TH INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, ND2022. - : EDP Sciences.
  • Conference paper (peer-reviewed)abstract
    • The neutron time-of-flight facility n_TOF is characterised by its high instantaneous neutron intensity, high resolution and broad neutron energy spectra, specially conceived for neutron-induced reaction cross section measurements. Two Time-Of-Flight (TOR) experimental areas are available at the facility: experimental area 1 (EAR1), located at the end of the 185 m horizontal flight path from the spallation target, and experimental area 2 (EAR2), placed at 20 m from the target in the vertical direction. The neutron fluence in EAR2 is similar to 300 times more intense than in EARL in the relevant time-of-flight window. EAR2 was designed to carry out challenging cross-section measurements with low mass samples (approximately 1 mg), reactions with small cross-sections or/and highly radioactive samples. The high instantaneous fluence of EAR2 results in high counting rates that challenge the existing capture systems. Therefore, the sTED detector has been designed to mitigate these effects. In 2021, a dedicated campaign was done validating the performance of the detector up to at least 300 keV neutron energy. After this campaign, the detector has been used to perform various capture cross section measurements at n_TOF EAR2.
  •  
5.
  • Alcayne, V., et al. (author)
  • A Segmented Total Energy Detector (sTED) optimized for (n,ϒ) cross-section measurements at n_TOF EAR2
  • 2024
  • In: Radiation Physics and Chemistry. - : Elsevier. - 0969-806X .- 1879-0895. ; 217
  • Journal article (peer-reviewed)abstract
    • The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutroninduced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of similar to 4 center dot 10(7) neutrons per nominal proton pulse, which is similar to 50 times higher than the one of Experimental ARea 1 (EAR1) of similar to 8 center dot 10(5) neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detector's response, by reducing the active volume per module and by using a photo-multiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to gamma-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2.
  •  
6.
  • Garcia-Infantes, F., et al. (author)
  • First high resolution measurement of neutron capture resonances in Yb-176 at the n_TOF CERN facility.
  • 2023
  • In: 15TH INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, ND2022. - : EDP Sciences.
  • Conference paper (peer-reviewed)abstract
    • Several international agencies recommend the study of new routes and new facilities for producing radioisotopes with application to nuclear medicine. Lu-177 is a versatile radioisotope used for therapy and diagnosis (theranostics) of cancer with good success in neuroendocrine tumours that is being studied to be applied to a wider range of tumours. Lu-177 is produced in few nuclear reactors mainly by the neutron capture on Lu-176. However, it could be produced at high -intensity accelerator-based neutron facilities. The energy of the neutrons in accelerator-based neutron facilities is higher than in thermal reactors. Thus, experimental data on the Yb-176(n,(sic)) cross-section in the eV and keV region are mandatory to calculate accurately the production of Yb-177, which beta decays to 177Lu. At present, there are not experimental data available from thermal to 3 keV of the Yb-176(n,(sic)) cross-section. In addition, there is no data in the resolved resonance region (RRR). This contribution shows the first results of the Yb-176 capture measurement performed at the n_TOF facility at CERN.
  •  
7.
  • Mucciola, R., et al. (author)
  • Neutron capture and total cross-section measurements on Mo-94'95'96 at n_TOF and GELINA
  • 2023
  • In: 15th International Conference on Nuclear Data for Science and Technology, ND2022. - : EDP Sciences.
  • Conference paper (peer-reviewed)abstract
    • Capture and total cross section measurements for 94'95'96 MO have been performed at the neutron time -of-flight facilities, n_TOF at CERN and GELINA at JRC-Geel. The measurements were performed using isotopically enriched samples with an enrichment above 95% for each of the (94'95'96)M0 isotopes. The capture measurements were performed at n_TOF using C6D6 detectors and a new sTED detector. The transmission measurements were performed at a 10 m station of GELINA using a Li-6 glass neutron detector. Preliminary results of these measurements are presented.
  •  
8.
  • Pleskac, R., et al. (author)
  • The FIRST experiment at GSI
  • 2012
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 678, s. 130-138
  • Journal article (peer-reviewed)abstract
    • The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at the SIS accelerator of GSl laboratory in Darmstadt has been designed for the measurement of ion fragmentation crosssections at different angles and energies between 100 and 1000 MeV/nucleon. Nuclear fragmentation processes are relevant in several fields of basic research and applied physics and are of particular interest for tumor therapy and for space radiation protection applications. The start of the scientific program of the FIRST experiment was on summer 2011 and was focused on the measurement of 400 MeV/nucleon C-12 beam fragmentation on thin (8 mm) graphite target. The detector is partly based on an already existing setup made of a dipole magnet (ALADiN). a time projection chamber (TP-MUSIC IV), a neutron detector (LAND) and a time of flight scintillator system (TOFWALL). This pre-existing setup has been integrated with newly designed detectors in the Interaction Region, around the carbon target placed in a sample changer. The new detectors are a scintillator Start Counter, a Beam Monitor drift chamber, a silicon Vertex Detector and a Proton Tagger scintillator system optimized for the detection of light fragments emitted at large angles. In this paper we review the experimental setup, then we present the simulation software, the data acquisition system and finally the trigger strategy of the experiment.
  •  
9.
  • Stamati, M. E., et al. (author)
  • The n_TOF NEAR Station Commissioning and first physics case
  • 2023
  • In: 15TH INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, ND2022. - : EDP Sciences.
  • Conference paper (peer-reviewed)abstract
    • The NEAR Station is a new experimental area developed at the n_TOF Facility at CERN. The activation station of NEAR underwent a characterization of the beam following the installation of the new n_TOF Spallation Target. The commissioning of the neutron beam comprises a set of simulations made with the FLUKA code and experimental verification. The experimental determination of the neutron spectrum was made using activation techniques with three separate set-ups. Two set-ups were based on the Multi-foil Activation technique (MAM-1 and MAM-2), and the third set-up relied on the process of neutron moderation and activation of a single material (ANTILoPE). The three set-ups are presented. Also the present plans and future perspectives of the activation station of NEAR are discussed.
  •  
10.
  • Tagliente, G., et al. (author)
  • The n_TOF facility at CERN
  • 2024
  • In: 16<sup>th</sup> Varenna Conference on Nuclear Reaction Mechanisms (NRM2023). - : EDP Sciences. - 9782759891245
  • Conference paper (peer-reviewed)abstract
    • The neutron Time-of-Flight facility (n_TOF) is an innovative facility operative since 2001 at CERN, with three experimental areas. In this paper the n_TOF facility will be described, together with the upgrade of the facility during the Long Shutdown 2 at CERN. The main features of the detectors used for capture fission cross section measurements will be presented with perspectives for the future measurements.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view