Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses

Daurer, Benedikt J. (author)
Okamoto, Kenta (author)
Bielecki, Johan (author)
show more...
Maia, Filipe R.N.C. (author)
Mühlig, Kerstin (author)
Seibert, M. Marvin (author)
Hantke, Max F. (author)
Nettelblad, Carl (author)
Benner, W. Henry (author)
Svenda, Martin (author)
Tîmneanu, Nicuşor (author)
Ekeberg, Tomas (author)
Loh, N. Duane (author)
Pietrini, Alberto (author)
Zani, Alessandro 1985- (author)
Rath, Asawari D. (author)
Westphal, Daniel (author)
Kirian, Richard A. (author)
Awel, Salah (author)
Wiedorn, Max O. (author)
van der Schot, Gijs (author)
Carlsson, Gunilla H. (author)
Hasse, Dirk (author)
Sellberg, Jonas A. (author)
Barty, Anton (author)
Andreasson, Jakob (author)
Boutet, Sebastian (author)
Williams, Garth (author)
Koglin, Jason (author)
Andersson, Inger (author)
Hajdu, Janos (author)
Larsson, Daniel S. D. (author)
show less...
 (publisher)
 (publisher)
show more...
 (publisher)
show less...
2017
2017
English.
In: IUCrJ. - 0972-6918. ; 4:3, 251-262
  • swepub:Mat__t
Abstract Subject headings
Close  
  • This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of similar to 40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from similar to 35 to similar to 300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 * 10(12) photons per mu m(2) per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. The results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

Subject headings

Natural Sciences  (hsv)
Chemical Sciences  (hsv)
Naturvetenskap  (hsv)
Kemi  (hsv)

Keyword

X-ray diffraction
free-electron laser
flash X-ray imaging
diffraction before destruction
virus
Omono River virus
OmRV

Find in a library

  • IUCrJ (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view