Accuracy in local staging of prostate cancer by adding a three-dimensional T2-weighted sequence with radial reconstructions in magnetic resonance imaging

Jäderling, Fredrik, 1964- (author)
Nyberg, Tommy (author)
Öberg, Michael (author)
show more...
Carlsson, Stefan (author)
Skorpil, Mikael (author)
Blomqvist, Lennart, 1960- (author)
show less...
 (publisher)
Sage Publications, 2018
2018
English.
In: Acta radiologica open. ; 7:2
  • swepub:Mat__t
Abstract Subject headings
Close  
  • Background: The evidence supporting the use of magnetic resonance imaging (MRI) in prostate cancer detection has been established, but its accuracy in local staging is questioned. Purpose: To investigate the additional value of multi-planar radial reconstructions of a three-dimensional (3D) T2-weighted (T2W) MRI sequence, intercepting the prostate capsule perpendicularly, for improving local staging of prostate cancer. Material and Methods: Preoperative, bi-parametric prostate MRI examinations in 94 patients operated between June 2014 and January 2015 where retrospectively reviewed by two experienced abdominal radiologists. Each patient was presented in two separate sets including diffusion-weighted imaging, without and with the 3D T2W set that included radial reconstructions. Each set was read at least two months apart. Extraprostatic tumor extension (EPE) was assessed according to a 5-point grading scale. Sensitivity and specificity for EPE was calculated and presented as receiver operating characteristics (ROC) with area under the curve (AUC), using histology from whole-mount prostate specimen as gold standard. Inter-rater agreement was calculated for the two different reading modes using Cohen's kappa. Results: The AUC for detection of EPE for Readers 1 and 2 in the two-dimensional (2D) set was 0.70 and 0.68, respectively, and for the 2D+3D set 0.62 and 0.65, respectively. Inter-rater agreement (Reader 1 vs. Reader 2) on EPE using Cohen's kappa for the 2D and 2D+3D set, respectively, was 0.42 and 0.17 (i.e. moderate and poor agreement, respectively). Conclusion: The addition of 3D T2W MRI with radial reconstructions did not improve local staging in prostate cancer.

Subject headings

Medical and Health Sciences  (ssif)
Clinical Medicine  (ssif)
Radiology, Nuclear Medicine and Medical Imaging  (ssif)
Medicin och hälsovetenskap  (ssif)
Klinisk medicin  (ssif)
Radiologi och bildbehandling  (ssif)

Genre

government publication  (marcgt)

Keyword

Prostate cancer
magnetic resonance imaging
staging
three-dimensional T2-weighted imaging

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Jäderling, Fredr ...
Nyberg, Tommy
Öberg, Michael
Carlsson, Stefan
Skorpil, Mikael
Blomqvist, Lenna ...
Articles in the publication
By the university
Swepub_uni:_t

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view