Deflections of an implant-supported cantilever beam subjected to vertically directed loads : in vitro measurements in three dimensions using an optoelectronic method. I. Experimental set-up.

Cassel, Björn (author)
Lundgren, Dan (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Karlsson, Dan (author)
Jönköping University,HHJ, Avdelningen för rehabilitering,HHJ. Ortopedteknisk plattform
 (creator_code:org_t)
2010-09-24
2011
English.
In: Clinical Oral Implants Research. - : Wiley. - 0905-7161 .- 1600-0501. ; 22:3, s. 275-281
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Aim: The aim of this in vitro study was to develop and test an experimental set-up consisting of a video camera and computer-based optoelectronic motion analysis system, synchronized with a loading device, for studying load-dependent deflections in three dimensions of single implant-supported cantilever beams.Material and methods: One Brånemark System implant was tightly screwed into a steel plate so that the entire implant became submerged. An abutment was attached to the implant and a cast 22-mm-long cantilever gold alloy beam incorporating a prefabricated gold cylinder was attached to the abutment with a prosthetic gold screw. A force transducer was glued on the upper surface of the beam end with its centre 19.4 mm from the centre of the implant abutment gold cylinder unit to register the applied load. A specially designed loading device was used to apply increasing vertical loads of the beam end via the transducer. The motion analysis system was synchronized with the transducer to enable measurements of three-dimensional positional changes of the beam end related to known loads.Results: Vertical loads from 15.7 to 40.4 N were applied resulting in vertical positional changes of the beam end ranging from 40.8 to 225.2 μm (z-axis). The corresponding horizontal changes perpendicular to the long axis of the beam (y-axis) due to counterclockwise horizontal rotation of the beam around the abutment- and prosthetic cylinder threads varied from 7.4 to 77.4 μm. This rotation changed the position of the beam end from 11.9 to 49.3 μm along the x-axis of the coordinate system toward the supporting implant.Conclusion: It was possible to arrange an experimental set-up for optoelectronic 3-D measurements within such a limited measurement volume that would permit satisfactory registrations of small load-dependent deflections of the prosthetic beam and implant components.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

3-D deflections
biomechanics
cantilever loads
experimental set-up
motions analysis system
screw joints

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Cassel, Björn
Lundgren, Dan
Karlsson, Dan
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
Clinical Oral Im ...
By the university
Jönköping University
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view