SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:hj-22711"
 

Search: onr:"swepub:oai:DiVA.org:hj-22711" > Digital filtering o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Starck, Sven-ÅkeGöteborgs universitet (author)

Digital filtering of bone scans : an ROC study

  • Article/chapterEnglish1997

Publisher, publication year, extent ...

  • Ovid Technologies (Wolters Kluwer Health),1997
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:hj-22711
  • https://urn.kb.se/resolve?urn=urn:nbn:se:hj:diva-22711URI
  • https://doi.org/10.1097/00006231-199702000-00002DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • The aims of this study were to investigate if digital filtering can increase the sensitivity and specificity of bone scans, and to find the type of filter most suitable for bone images at various count levels. We also wished to examine if filtering allows the administered activity or the examination time to be reduced, and if it is easier to detect low-contrast uptake using a digital filter. Images containing a total of 100, 350 and 1000 kcounts were acquired in a 256 x 256 matrix using a transmission phantom simulating the thoracolumbar region. Receiver operating characteristic (ROC) analysis demonstrated that digital filtering increases the sensitivity and specificity of bone scintigraphy. A low-pass filter for images with low statistics (100 kcounts), which contain 2-5 counts per pixel in the ribs and vertebrae respectively, and a Metz filter for images with normal (5-19 counts per pixel) to good (20-54 counts per pixel) statistics, increase the area under the ROC curve significantly (99% confidence level) compared to unfiltered images. Filtering also increases the detectability of low-contrast objects compared with unfiltered images. Digital filtering might be an alternative to raising the number of counts in the image. An alternative is to reduce the administered activity and hence the effective dose to the patient, or to reduce the examination time-which is an advantage when treating elderly patients or patients with pain.

Added entries (persons, corporate bodies, meetings, titles ...)

  • Carlsson, Sten (author)
  • Göteborgs universitet (creator_code:org_t)

Related titles

  • In:Nuclear medicine communications: Ovid Technologies (Wolters Kluwer Health)18:2, s. 98-1040143-36361473-5628

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Starck, Sven-Åke
Carlsson, Sten
Articles in the publication
Nuclear medicine ...
By the university
Jönköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view