SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:hj-63328"
 

Search: onr:"swepub:oai:DiVA.org:hj-63328" > Pulsed tissue Doppl...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Pulsed tissue Doppler imaging for the detection of myocardial ischaemia, a comparison with myocardial perfusion SPECT

Blomstrand, Peter (author)
County Hospital Ryhov, Jönköping, Sweden
Maret, Eva (author)
Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet
Ohlsson, Jan (author)
County Hospital Ryhov, Jönköping, Sweden
show more...
Scheike, Morten (author)
Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet
Karlsson, Jan-Erik (author)
County Hospital Ryhov, Jönköping, Sweden
Säfström, Kåge (author)
Östergötlands Läns Landsting,Linköpings universitet,Kardiologi,Hälsouniversitetet,Kardiologiska kliniken
Swahn, Eva (author)
Linköpings universitet,Kardiologi,Hälsouniversitetet
Engvall, Jan (author)
Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet
show less...
 (creator_code:org_t)
John Wiley & Sons, 2004
2004
English.
In: Clinical Physiology and Functional Imaging. - : John Wiley & Sons. - 1475-0961 .- 1475-097X. ; 24:5, s. 289-295
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • In order to compare the diagnostic ability of pulsed tissue Doppler and myocardial perfusion Single Photon Emission Computed Tomography (SPECT) in patients with a history of unstable coronary artery disease, CAD, 26 patients, 22 men and four women, age 47-76 years, were investigated in a prospective study, 5-10 day after an episode of unstable angina. Tissue Doppler and two-dimensional echocardiography were performed during dobutamine stress testing and myocardial scintigraphy after bicycle exercise and at rest. Patients with a normal SPECT had higher peak systolic velocity during dobutamine infusion, 18.9 ± 4.1 cm s-1, than patients with ischaemia, 12.2 ± 3.8 cm s-1 (P<0.001) or scar, 8.8 ± 3.0 cm s-1 (P<0.01). In a territorial analysis the difference in peak systolic velocity between areas with a normal and abnormal SPECT was less apparent. Failure to achieve ≥13 cm s-1 in mean-peak systolic velocity was the most accurate criterion for detection of significant CAD on SPECT. We conclude that pulsed tissue Doppler can be used for objective quantification of left ventricular wall motion during dobutamine stress testing and for identification of patients with CAD on SPECT but not for identification of regional ischaemia.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Keyword

Dobutamine
Echocardiography
Myocardial perfusion SPECT
Tissue Doppler
atropine
tetrofosmin tc 99m
adult
aged
article
bicycle ergometry
clinical article
clinical trial
controlled clinical trial
controlled study
diagnostic value
Doppler echocardiography
drug infusion
female
heart left ventricle contraction
heart left ventricle wall motion
heart perfusion
human
image analysis
intermethod comparison
ischemic heart disease
male
priority journal
prospective study
rest
scintillation camera
single photon emission computer tomography
statistical significance
stress echocardiography
two dimensional echocardiography
unstable angina pectoris
MEDICINE

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view