SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:kau-40472"
 

Search: onr:"swepub:oai:DiVA.org:kau-40472" > A new reliable tool...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A new reliable tool (PVC assess) for assessment of peripheral venous catheters

Ahlqvist, Margary (author)
Karolinska Univ Hosp Huddinge, Karolinska Inst, Div Surg, Dept Clin Sci Intervent & Technol, SE-14186 Stockholm, Sweden.
Berglund, Britta (author)
Karolinska Institutet
Nordström, Gun (author)
Karlstads universitet,Institutionen för hälsovetenskaper (from 2013)
show more...
Klang, Birgitta (author)
Karolinska Inst, Dept Neurobiol Care Sci & Soc, Stockholm, Sweden.
Wiren, Mikael (author)
Karolinska Univ Hosp Huddinge, Karolinska Inst, Div Surg, Dept Clin Sci Intervent & Technol, SE-14186 Stockholm, Sweden.
Johansson, Eva (author)
Karolinska Institutet
show less...
Karolinska Institutet Karolinska Univ Hosp Huddinge, Karolinska Inst, Div Surg, Dept Clin Sci Intervent & Technol, SE-14186 Stockholm, Sweden (creator_code:org_t)
2010-12-22
2010
English.
In: Journal of Evaluation In Clinical Practice. - : Wiley. - 1356-1294 .- 1365-2753. ; 16:6, s. 1108-1115
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Rationale and aims To evaluate the extensive use of peripheral venous catheters (PVCs), including catheter-related complications, a reliable tool for PVC assessment is needed. The aim of this study was to develop such a tool to evaluate PVCs in relation to management, documentation and signs and symptoms of thrombophlebitis (TH), as well as to determine its inter-rater and test-retest reliability. Method The tool development included confirmation of content and face validity. Two groups of registered nurses used the new tool (PVC assess) to assess PVC management and signs of TH independently. Group A (n = 3) assessed 26 items in 67 PVCs bedside (inter-rater reliability). Group B (n = 3) assessed photographs (67 PVCs, 21 items) of the same PVCs as those in Group A with a 4-week interval (test-retest reliability). Proportion of agreement P(A) and Cohen's kappa were calculated to evaluate inter-rater and test-retest reliability. Results Among nurses assessing PVCs at bedside, the P(A) was good to excellent (0.80-1) in 96% of the items in PVC assess. In 80% of the items kappa was substantial to almost perfect (0.61-1). TH sign erythema fell into the fair range (kappa = 0.40). In test-retest reliability analysis the P(A) was within the good and excellent range (0.80-1.0) and kappa varied from moderate to almost perfect (0.41-1.0) in 95% of the items. One item 'outer dressing is clean' was in fair range (0.21-0.40). Conclusions The PVC assess instrument shows satisfactory inter-rater and test-retest reliability. Reliability tests on reviewing documentation remain to be performed.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Omvårdnad (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Nursing (hsv//eng)

Keyword

assessment
inter-rater reliability
peripheral venous catheters
test-retest reliability
tool development
Omvårdnad
Nursing Science

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view