SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:kth-109170"
 

Search: onr:"swepub:oai:DiVA.org:kth-109170" > Automated improveme...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Fredriksson, AlbinKTH,Optimeringslära och systemteori (author)

Automated improvement of radiation therapy treatment plans by optimization under reference dose constraints

  • Article/chapterEnglish2012

Publisher, publication year, extent ...

  • 2012-11-06
  • IOP Publishing,2012
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:kth-109170
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-109170URI
  • https://doi.org/10.1088/0031-9155/57/23/7799DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • QC 20121221
  • A method is presented that automatically improves upon previous treatment plans by optimization under reference dose constraints. In such an optimization, a previous plan is taken as reference and a new optimization is performed toward some goal, such as minimization of the doses to healthy structures under the constraint that no structure can become worse off than in the reference plan. Two types of constraints that enforce this are discussed: either each voxel or each dose-volume histogram of the improved plan must be at least as good as in the reference plan. These constraints ensure that the quality of the dose distribution cannot deteriorate, something that constraints on conventional physical penalty functions do not. To avoid discontinuous gradients, which may restrain gradient-based optimization algorithms, the positive part operators that constitute the optimization functions are regularized. The method was applied to a previously optimized plan for a C-shaped phantom and the effects of the choice of regularization parameter were studied. The method resulted in reduced integral dose and reduced doses to the organ at risk while maintaining target homogeneity. It could be used to improve upon treatment plans directly or as a means of quality control of plans.

Subject headings and genre

  • Imrt
  • Penalty
  • Prescription
  • Radiotherapy
  • Quality

Added entries (persons, corporate bodies, meetings, titles ...)

  • KTHOptimeringslära och systemteori (creator_code:org_t)

Related titles

  • In:Physics in Medicine and Biology: IOP Publishing57:23, s. 7799-78110031-91551361-6560

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Fredriksson, Alb ...
Articles in the publication
Physics in Medic ...
By the university
Royal Institute of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view