Energy resolution of a photon-counting silicon strip detector
-
- Fredenberg, Erik, PhD, 1979- (author)
- KTH,Medicinsk bildfysik,Medical Imaging
-
- Lundqvist, Mats (author)
- Sectra Mamea AB, Smidesvägen 5, SE-171 41 Solna, Sweden
-
- Cederström, Björn (author)
- KTH,Medicinsk bildfysik,Medical Imaging
-
show more...
-
- Åslund, Magnus (author)
- Sectra Mamea AB, Smidesvägen 5, SE-171 41 Solna, Sweden
-
- Danielsson, Mats (author)
- KTH,Medicinsk bildfysik,Medical Imaging
-
show less...
-
(creator_code:org_t)
- Elsevier BV, 2010
- 2010
- English.
-
In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; , s. 156-162
- Related links:
-
https://kth.diva-por... (primary) (Raw object)
-
show more...
-
http://kth.diva-port...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present study is optimization with respect to energy resolution. Factors relevant for the energy response were measured, simulated, or gathered from previous studies, and used as input parameters to a cascaded detector model. Threshold scans over several X-ray spectra were used to calibrate threshold levels to energy, and to validate the model. The energy resolution of the detector assembly was assessed to range over ΔE/E=0.12–0.26 in the mammography region. Electronic noise dominated the peak broadening, followed by charge sharing between adjacent detector strips, and a channel-to-channel threshold spread. The energy resolution may be improved substantially if these effects are reduced to a minimum. Anti-coincidence logic mitigated double counting from charge sharing, but erased the energy resolution of all detected events, and optimization of the logic is desirable. Pile-up was found to be of minor importance at typical mammography rates.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Keyword
- Spectral X-ray imaging
- Mammography; Silicon strip detector
- Photon counting
- Energy resolution
- Cascaded detector model
- Electrical engineering, electronics and photonics
- Elektroteknik, elektronik och fotonik
- Medical engineering
- Medicinsk teknik
- Other engineering physics
- Övrig teknisk fysik
- Radiological research
- Radiologisk forskning
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database