Search: onr:"swepub:oai:DiVA.org:kth-12208" >
A packaged optical ...
A packaged optical slot-waveguide ring resonator sensor array for multiplex label-free assays in labs-on-chips
-
- Carlborg, Carl Fredrik (author)
- KTH,Mikrosystemteknik
-
- Gylfason, Kristinn Björgvin (author)
- KTH,Mikrosystemteknik
-
Kazmierczak, Andrzej (author)
-
show more...
-
Dortu, Fabian (author)
-
Banuls Polo, Maria Jose (author)
-
Maquieira Catala, Angel (author)
-
Kresbach, Gerhard (author)
-
- Sohlström, Hans (author)
- KTH,Mikrosystemteknik
-
- Moh, Thomas (author)
- KTH,Mikrosystemteknik
-
Vivien, Laurent (author)
-
Popplewell, Jon (author)
-
Ronan, Gerry (author)
-
Barrios, Carlos Angulo (author)
-
- Stemme, Göran (author)
- KTH,Mikrosystemteknik
-
- van der Wijngaart, Wouter (author)
- KTH,Mikrosystemteknik
-
show less...
-
(creator_code:org_t)
- 2010
- 2010
- English.
-
In: Lab on a Chip. - : Royal Society of Chemistry (RSC). - 1473-0197 .- 1473-0189. ; 10:3, s. 281-290
- Related links:
-
https://kth.diva-por... (primary) (Raw object)
-
show more...
-
http://kth.diva-port...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- We present the design, fabrication, and characterisation of an array of optical slot-waveguide ring resonator sensors, integrated with microfluidic sample handling in a compact cartridge, for multiplexed real-time label-free biosensing. Multiplexing not only enables high throughput, but also provides reference channels for drift compensation and control experiments. Our use of alignment tolerant surface gratings to couple light into the optical chip enables quick replacement of cartridges in the read-out instrument. Furthermore, our novel use of a dual surface-energy adhesive film to bond a hard plastic shell directly to the PDMS microfluidic network allows for fast and leak-tight assembly of compact cartridges with tightly spaced fluidic interconnects. The high sensitivity of the slot-waveguide resonators, combined with on-chip referencing and physical modelling, yields a volume refractive index detection limit of 5 x 10(-6) refractive index units (RIUs) and a surface mass density detection limit of 0.9 pg mm(-2), to our knowledge the best reported values for integrated planar ring resonators.
Keyword
- MICRORING RESONATOR
- SILICON
- INTERFACE
- BIOSENSOR
- SYSTEMS
- TECHNOLOGY
- TEKNIKVETENSKAP
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database
- By the author/editor
-
Carlborg, Carl F ...
-
Gylfason, Kristi ...
-
Kazmierczak, And ...
-
Dortu, Fabian
-
Banuls Polo, Mar ...
-
Maquieira Catala ...
-
show more...
-
Kresbach, Gerhar ...
-
Sohlström, Hans
-
Moh, Thomas
-
Vivien, Laurent
-
Popplewell, Jon
-
Ronan, Gerry
-
Barrios, Carlos ...
-
Stemme, Göran
-
van der Wijngaar ...
-
show less...
- Articles in the publication
-
Lab on a Chip
- By the university
-
Royal Institute of Technology