SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:kth-122109"
 

Search: onr:"swepub:oai:DiVA.org:kth-122109" > Cellular Dose of Pa...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Cellular Dose of Partly Soluble Cu Particle Aerosols at the Air-Liquid Interface Using an In Vitro Lung Cell Exposure System

Elihn, Karine (author)
Stockholms universitet,Institutionen för tillämpad miljövetenskap (ITM)
Cronholm, Pontus (author)
Karlsson, Hanna L. (author)
Karolinska Institutet
show more...
Midander, Klara (author)
KTH,Yt- och korrosionsvetenskap
Odnevall Wallinder, Inger (author)
KTH,Yt- och korrosionsvetenskap
Möller, Lennart (author)
Karolinska Institutet
show less...
 (creator_code:org_t)
Mary Ann Liebert Inc, 2013
2013
English.
In: Journal of Aerosol Medicine. - : Mary Ann Liebert Inc. - 1941-2711 .- 1941-2703. ; 26:2, s. 84-93
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background: There is currently a need to develop and test in vitro systems for predicting the toxicity of nanoparticles. One challenge is to determine the actual cellular dose of nanoparticles after exposure. Methods: In this study, human epithelial lung cells (A549) were exposed to airborne Cu particles at the air-liquid interface (ALI). The cellular dose was determined for two different particle sizes at different deposition conditions, including constant and pulsed Cu aerosol flow. Results: Airborne polydisperse particles with a geometric mean diameter (GMD) of 180nm [geometric standard deviation (GSD) 1.5, concentration 10(5) particles/mL] deposited at the ALI yielded a cellular dose of 0.4-2.6 mu g/cm(2) at pulsed flow and 1.6-7.6 mu g/cm(2) at constant flow. Smaller polydisperse particles in the nanoregime (GMD 80 nm, GSD 1.5, concentration 10(7) particles/mL) resulted in a lower cellular dose of 0.01-0.05 mu g/cm(2) at pulsed flow, whereas no deposition was observed at constant flow. Exposure experiments with and without cells showed that the Cu particles were partly dissolved upon deposition on cells and in contact with medium. Conclusions: Different cellular doses were obtained for the different Cu particle sizes (generated with different methods). Furthermore, the cellular doses were affected by the flow conditions in the cell exposure system and the solubility of Cu. The cellular doses of Cu presented here are the amount of Cu that remained on the cells after completion of an experiment. As Cu particles were partly dissolved, Cu (a nonnegligible contribution) was, in addition, present and analyzed in the nourishing medium present beneath the cells. This study presents cellular doses induced by Cu particles and demonstrates difficulties with deposition of nanoparticles at the ALI and of partially soluble particles.

Subject headings

NATURVETENSKAP  -- Geovetenskap och miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Annan medicin och hälsovetenskap -- Övrig annan medicin och hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Other Medical and Health Sciences -- Other Medical and Health Sciences not elsewhere specified (hsv//eng)

Keyword

in vitro exposure system
air-liquid interface
copper particles
nanoparticle deposition
nanoparticle dissolution
cellular doses
nanotoxicology

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view