Search: onr:"swepub:oai:DiVA.org:kth-179948" >
Consistent intensit...
Consistent intensity inhomogeneity correction in water-fat MRI
-
- Andersson, Thord (author)
- Linköpings universitet,Medicinsk informatik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
-
- Romu, Thobias (author)
- Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
-
- Karlsson, Anette (author)
- Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
-
show more...
-
- Norén, Bengt (author)
- Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping
-
- Forsgren, Mikael (author)
- Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Radiofysikavdelningen US
-
- Smedby, Örjan, 1956- (author)
- Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping
-
- Kechagias, Stergios (author)
- Linköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Region Östergötland, Magtarmmedicinska kliniken
-
- Almer, Sven (author)
- Linköpings universitet,Karolinska Institutet,Avdelningen för neuro- och inflammationsvetenskap,Medicinska fakulteten,Region Östergötland, Magtarmmedicinska kliniken
-
- Lundberg, Peter (author)
- Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Radiofysikavdelningen US,Region Östergötland, Röntgenkliniken i Linköping
-
- Borga, Magnus (author)
- Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Centrum för medicinsk bildvetenskap och visualisering, CMIV
-
- Dahlqvist Leinhard, Olof (author)
- Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Radiofysikavdelningen US
-
show less...
-
(creator_code:org_t)
- 2014-10-30
- 2015
- English.
-
In: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 42:2
- Related links:
-
http://liu.diva-port...
-
show more...
-
https://liu.diva-por... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
http://kipublication...
-
https://urn.kb.se/re...
-
show less...
Abstract
Subject headings
Close
- PURPOSE: To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneitiesMETHODS: Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subjects acquired with both 1.5T and 3.0T whole-body MRI. (ii) Seven liver tissue ROIs from 36 patients imaged using 1.5T MRI at six time points after Gd-EOB-DTPA injection. The performance of CIIC was evaluated quantitatively by analyzing its impact on the dispersion and bias of the water image ROI intensities, and qualitatively using side-by-side image comparisons.RESULTS: CIIC significantly ( P1.5T≤2.3×10-4,P3.0T≤1.0×10-6) decreased the nonphysiological intensity variance while preserving the average intensity levels. The side-by-side comparisons showed improved intensity consistency ( Pint≤10-6) while not introducing artifacts ( Part=0.024) nor changed appearances ( Papp≤10-6).CONCLUSION: CIIC improves the spatiotemporal intensity consistency in regions of a homogenous tissue type.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Image Processing (hsv//eng)
Keyword
- Medical Technology
- Medicinsk teknologi
- water–fat imaging;Dixon imaging;inhomogeneity correction;intensity correction;water;fat quantification
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database
- By the author/editor
-
Andersson, Thord
-
Romu, Thobias
-
Karlsson, Anette
-
Norén, Bengt
-
Forsgren, Mikael
-
Smedby, Örjan, 1 ...
-
show more...
-
Kechagias, Sterg ...
-
Almer, Sven
-
Lundberg, Peter
-
Borga, Magnus
-
Dahlqvist Leinha ...
-
show less...
- About the subject
-
- MEDICAL AND HEALTH SCIENCES
-
MEDICAL AND HEAL ...
-
and Clinical Medicin ...
-
and Radiology Nuclea ...
-
- ENGINEERING AND TECHNOLOGY
-
ENGINEERING AND ...
-
and Medical Engineer ...
-
and Medical Image Pr ...
- Articles in the publication
-
Journal of Magne ...
- By the university
-
Royal Institute of Technology
-
Karolinska Institutet
-