Diagnostic accuracy of digital mammography versus tomosynthesis : effect of radiologists' experience
-
Zanca, Federica (author)
-
Wallis, Matthew G. (author)
-
Moa, Elin (author)
-
show more...
-
Leifland, Karin (author)
-
- Danielsson, Mats, 1965- (author)
- Sectra Mamea AB, Sweden,Physics of Medical Imaging
-
Oyen, Raymond (author)
-
Bosmans, Hilde (author)
-
show less...
-
(creator_code:org_t)
- International Society for Optics and Photonics : SPIE, 2012
- 2012
- English.
-
In: Medical Imaging 2012. - International Society for Optics and Photonics : SPIE. - 9780819489678 ; , s. 83180-83180
- Related links:
-
http://proceedings.s...
-
show more...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Purpose: To investigate whether readers' experience affects performance in a study comparing 2D digital mammography (2D) with 2-view (CC and MLO) or 1-view (MLO) tomosynthesis. Materials and Methods: One-hundred-thirty 2D cases were collected from screening assessment and referral clinics; 64 of the cases had verified abnormalities and the remaining were confirmed normal. Two-view tomosynthesis images were obtained from the same patients. Ten accredited readers (5 with ≥ 10 years experience in mammography and 5 with < 10 years) classified the cases in terms of malignancy (rate 0-5), and recall (yes/no), for both modalities. A second experiment was performed with the same cases, with 10 other readers (again 5 experienced / 5 less experienced), but using 2D and 1-view tomosynthesis as the two modalities. The multi-reader-multi-case ROC method was applied and the significance of diagnostic accuracy difference of 2D vs tomosynthesis was calculated, as a function of experience and for each experiment. Recall rate (RR) on malignant and benign cases was also calculated, along with reading time. Results: No significant difference was reached between 2D and 2-view tomosynthesis for experienced readers (pvalue= 0.25); for less experienced readers the p-value was significant (0.03). No significant difference was found between 2D and 1-view tomosynthesis, independent of readers' experience. RR for benign cases decreased for tomosynthesis (for booth 1- and 2-view), independent of experience. Average reading time per case was 79 s (range 65- 91 s) and 134 s (range 119-158 s) for experienced readers; 56 s (range 46-67 s) and 115s (range 97-142 s) for nonexperienced, for 2D and 2-view tomosynthesis respectively. Reading time was 74 s (range 43-98 s) and 99 s (range 73- 117 s) for experienced readers; 74 s (range 62-85 s) and 94 s (range 82-137 s) for non-experienced, for 2D and 1-view tomosynthesis respectively. Conclusions: For experienced readers, there is no evidence of improved diagnostic accuracy when using 2-view or 1- view tomosynthesis, while less experienced readers perform better with 2-view tomosynthesis than 2D images. Tomosynthesis reduces the number of recall of benign cases, without hindering cancer detection.
Subject headings
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Image Processing (hsv//eng)
Keyword
- Medical Imaging
- Diagnostic
- digital mammography
- tomosynthesis
- Fysik
- Physics
- Medical Technology
- Medicinsk teknologi
Publication and Content Type
- ref (subject category)
- kon (subject category)
Find in a library
To the university's database