SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:kth-186323"
 

Search: onr:"swepub:oai:DiVA.org:kth-186323" > Choice of grating o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Choice of grating orientation for evaluation of peripheral vision

Venkataraman, Abinaya Priya (author)
KTH,Biomedicinsk fysik och röntgenfysik
Winter, Simon (author)
KTH,Biomedicinsk fysik och röntgenfysik
Rosén, Robert (author)
KTH,Biomedicinsk fysik och röntgenfysik
show more...
Lundström, Linda (author)
KTH,Biomedicinsk fysik och röntgenfysik
show less...
 (creator_code:org_t)
Lippincott Williams & Wilkins, 2016
2016
English.
In: Optometry and Vision Science. - : Lippincott Williams & Wilkins. - 1040-5488 .- 1538-9235. ; 93:6, s. 567-574
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Purpose: Peripheral resolution acuity depends on the orientation of the stimuli. However, it is uncertain if such a meridional effect also exists for peripheral detection tasks because they are affected by optical errors. Knowledge of the quantitative differences in acuity for different grating orientations is crucial for choosing the appropriate stimuli for evaluations of peripheral resolution and detection tasks. We assessed resolution and detection thresholds for different grating orientations in the peripheral visual field.Methods: Resolution and detection thresholds were evaluated for gratings of four different orientations in eight different visual field meridians in the 20-deg visual field in white light. Detection measurements in monochromatic light (543 nm; bandwidth, 10 nm) were also performed to evaluate the effects of chromatic aberration on the meridional effect. A combination of trial lenses and adaptive optics system was used to correct the monochromatic lower- and higher-order aberrations.Results: For both resolution and detection tasks, gratings parallel to the visual field meridian had better threshold compared with the perpendicular gratings, whereas the two oblique gratings had similar thresholds. The parallel and perpendicular grating acuity differences for resolution and detection tasks were 0.16 logMAR and 0.11 logMAD, respectively. Elimination of chromatic errors did not affect the meridional preference in detection acuity.Conclusions: Similar to peripheral resolution, detection also shows a meridional effect that appears to have a neural origin. The threshold difference seen for parallel and perpendicular gratings suggests the use of two oblique gratings as stimuli in alternative forced-choice procedures for peripheral vision evaluation to reduce measurement variation.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Keyword

grating orientation
peripheral vision
resolution
detection
meridional effect
psychophysics
forced-choice procedure

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Venkataraman, Ab ...
Winter, Simon
Rosén, Robert
Lundström, Linda
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Ophthalmology
Articles in the publication
Optometry and Vi ...
By the university
Royal Institute of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view