SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-20385"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-20385" > Comparison of two l...

Comparison of two landmark based image registration methods for use with a body atlas

Crafoord, Joakim (författare)
Karolinska Hospital, Department of Radiology
Mahmoud, Faaiza (författare)
New York University, Department of Radiology
Kramer, Elissa L. (författare)
New York University, Department of Radiology
visa fler...
Maguire Jr., Gerald Q. (författare)
KTH,Mikroelektronik och informationsteknik, IMIT
Noz, Marilyn E. (författare)
New York University, Department of Radiology,Nuclear Medicine
Zeleznik, Michael P. (författare)
RAHD Oncology Products, St. Lois, MO, USA
visa färre...
 (creator_code:org_t)
2000
2000
Engelska.
Ingår i: Physica medica (Testo stampato). - 1120-1797 .- 1724-191X. ; 16:2, s. 75-82
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We describe preliminary work registering abdominal MRI images from three healthy male volunteers. Anatomically selected 3D homologous point pairs (landmarks), from which eigenvalues were generated to form the basis for a 3D non-affine polynomial transformation, were placed on axial slices alone and on axial, coronal and sagittal slices. Registration accuracy was judged visually by comparing superimposed 3D isosurfaces from the reference, untransformed, and transformed volume data and by comparing merged 2D slices projected fi om the transformed and reference volume data superimposed with 2D isolines. The squared sum of intensity differences between the transformed/untransformed and the reference volume was significant at the 0.05 (p >0.05) confidence level. The correlation coefficient improved by an average of 38% and the cross correlation between pixel values improved by an average of 22%. In each trial, the standard deviation of the landmarks after transformation was within one voxel and the standard error of the mean was not significantly different from zero at the 0.05 confidence level. Abdominal isosurface volume differences (between individuals) changed from an average of 14.5% before registration to 2.9% after registration. This experiment shows that it is possible to choose landmarks such that abdominal data from different subject volumes can be mapped to a common reference, and thus that it is possible to use this combined volume both to form an atlas and to warp abdominal data from an atlas to a patient volume.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

image fusion
deformable body atlas
interpatient registration
emission tomography
brain atlas
mr-images
algorithm
pet
ct
SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy