SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:kth-215801"
 

Search: onr:"swepub:oai:DiVA.org:kth-215801" > A Hidden Markov Mod...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

A Hidden Markov Model for Seismocardiography

Wahlström, Johan (author)
KTH,ACCESS Linnaeus Centre,Signalbehandling
Skog, Isaac, 1981- (author)
KTH,ACCESS Linnaeus Centre,Signalbehandling
Händel, Peter, 1962- (author)
KTH,ACCESS Linnaeus Centre,Signalbehandling
show more...
Khosrow-Khavar, Farzad (author)
Tavakolian, Kouhyar (author)
Stein, Phyllis K. (author)
Nehorai, Arye (author)
show less...
 (creator_code:org_t)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2017
2017
English.
In: IEEE Transactions on Biomedical Engineering. - : IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. - 0018-9294 .- 1558-2531. ; 64:10, s. 2361-2372
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • We propose a hidden Markov model approach for processing seismocardiograms. The seismocardiogram morphology is learned using the expectation-maximization algorithm, and the state of the heart at a given time instant is estimated by the Viterbi algorithm. From the obtained Viterbi sequence, it is then straightforward to estimate instantaneous heart rate, heart rate variability measures, and cardiac time intervals (the latter requiring a small number of manual annotations). As is shown in the conducted experimental study, the presented algorithm outperforms the state-of-the-art in seismocardiogram-based heart rate and heart rate variability estimation. Moreover, the isovolumic contraction time and the left ventricular ejection time are estimated with mean absolute errors of about 5 [ms] and 9 [ms], respectively. The proposed algorithm can be applied to any set of inertial sensors; does not require access to any additional sensor modalities; does not make any assumptions on the seismocardiogram morphology; and explicitly models sensor noise and beat-to-beat variations (both in amplitude and temporal scaling) in the seismocardiogram morphology. As such, it is well suited for low-cost implementations using off-the-shelf inertial sensors and targeting, e.g., at-home medical services.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Keyword

Cardiac time intervals
heart rate variability (HRV)
hidden Markov model (HMM)
seismocardiogram (SCG)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view