SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:kth-238761"
 

Search: onr:"swepub:oai:DiVA.org:kth-238761" > Lightning subsequen...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Lightning subsequent-stroke electric field peak greater than the first stroke peak and multiple ground terminations

Thottappillil, Rajeev, 1958- (author)
University of Florida, Gainesville, USA
Rakov, V. A. (author)
University of Florida, Gainesville, USA
Uman, M. A. (author)
University of Florida, Gainesville, USA
show more...
Beasley, W. H. (author)
University of Oklahoma, Norman, USA
Master, M. J. (author)
AT&T Bell Laboratories, New Jersey, USA
Shelukhin, D. V. (author)
High Voltage Research Institute, Tomsk, Russia
show less...
 (creator_code:org_t)
1992
1992
English.
In: Journal of Geophysical Research - Atmospheres. - 2169-897X .- 2169-8996. ; 97:D7, s. 7503-7509
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • For 46 multiple-stroke flashes in which each stroke ground termination was located using a TV camera network and thunder ranging, 15 flashes (33%) had one or more subsequent return strokes whose initial electric field peak normalized to 100 km was greater than the first-stroke field peak of the flash. In 9 of these 15 flashes the subsequent strokes with field peaks greater than the first stroke followed the same channel as the first stroke; in five flashes the subsequent strokes with the greater peaks followed a different channel to ground; and in one flash the subsequent strokes with the greater peaks occurred both in the first-stroke channel and in a different channel. The interstroke intervals immediately preceding the 13 larger subsequent strokes that followed the first-stroke channel had a geometric mean (GM) duration of 98 ms, 1.7 times greater than the GM of 57 ms for all 199 interstroke intervals (46 flashes) without any selection. Eight of the 13 larger subsequent strokes for which leader durations were measurable had a GM leader duration of 0.55 ms, 3.3 times smaller than the GM of 1.8 ms for 117 subsequent leaders with measurable duration in a previously formed channel of the 46 multiple-stroke flashes. For the six larger subsequent strokes that created a new channel to ground, the preceding interstroke interval had a GM of 130 ms, and the leader duration had a GM of 15 ms. No subsequent stroke with peak field exceeding the first in any category had a preceding interstroke interval less than 35 ms. Analysis of direct current measurements from Switzerland shows that subsequent-stroke currents exhibit many features similar to those of Florida subsequent-stroke electric fields. In 22 Florida single-stroke and multiple-stroke ground flashes the distances between multiple channel terminations in a given flash (33 measurements) ranged from 0.3 km to 7.3 km, with a GM of 1.7 km.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Keyword

Lightning
Electromagnetic Compatibility

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view