SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-115838"
 

Search: onr:"swepub:oai:DiVA.org:liu-115838" > Textile electrodes ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Textile electrodes for ECG measurements in distributed care, performance and applications

Rattfält, Linda (author)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
Ask, Per, Professor (thesis advisor)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
Hult, Peter, Dr. (thesis advisor)
Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan
show more...
Lindén, Maria (thesis advisor)
show less...
 (creator_code:org_t)
ISBN 9789173934473
Linköping : Department of Biomedical Engineering, Linköpings universitet, 2010
English 43 s.
Series: Linköping Studies in Science and Technology. Thesis, 0280-7971 ; 1429
  • Licentiate thesis (other academic/artistic)
Abstract Subject headings
Close  
  • The aim of this thesis work has been to explore textile electrodes for electrocardiographic (ECG) measurements both in terms of their electrode properties and possibility to further improve their robustness to noise with signal processing techniques. Previous research within the field has shown that acquisition of ECG is possible with textile electrodes, but little attention has been focused on how they function and especially if movements are included in the measurement protocol.In a first study, the electrical properties of conductive textiles were evaluated in the same manner as conventional Ag/AgCl ECG electrodes. Three yarns and textile electrode surfaces were tested. The electrodes made from pure stainless steel (A) and 20% stainless steel/ 80% polyester (B) showed acceptable stability of electrode potentials. The electrode made from silver plated copper (C) was less robust. The best electrode impedance characteristic had Electrode A and hence from an electrical properties point of view we recommend electrodes of type A to be used for ECG measurements.The second paper contains an application of canonical correlation analysis (CCA) on multi channel ECG signals recorded with textile electrodes. Using CCA to solve the blind source separation (BSS) problem, we intended to separate the ECG signal from the various noise sources. The method (CCABSS) was compared to averaging of the ECG channels and to the independent component analysis method (ICA). Results show a loss of the ECG signal while simulating various noise in 33%, 17% and 7% of the cases for averaging, ICA and CCA, respectively.A drawback with the CCABSS approach is however that it produces many outputs and that information regarding the wanted feature to detect is not included in the analysis. In the third article, an event detector based on a multichannel input, a model of the event and weighted correlation was used instead. For measurements at rest and upper body rotation, the sensitivity was 100% and 99% respectively. Muscle tension and walking were the hardest to detect with a sensitivity of 88% and 91% respectively.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Publication and Content Type

vet (subject category)
lic (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Rattfält, Linda
Ask, Per, Profes ...
Hult, Peter, Dr.
Lindén, Maria
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Electrical Engin ...
Parts in the series
Linköping Studie ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view